Heat Pump List

Tools

MDV-V18WMN10T

MDV-V18WMN10T is in the certified data.

Its certified full-speed heating output at 5°F is 14,400–18,000 Btu/h, 80–100% of its 47°F rating (tests at different compressor speeds), depending on the pairing.

Midea · central heat pump

All 359 certified Midea models

MDV-V18WMN10T is in the certified data as of Sep 19, 2026. MDV-V18WMN10T changed its certified heat output at 47°F on 3 pairings from 18,200 Btu/h to 20,000 Btu/h in the certified data between August 2025 and September 2026.

8 certified pairings with 7 different figures. See all

Certified heating and cooling

Heating at 47°F

18,000

15,100 at 17°F

18,000 at 5°F

Btu/h, certified

1.95 COP at 5°F

Cooling at 95°F

18,000

Btu/h, certified

EER2 12.0 at 95°F

SEER2 17.1

Heating and cooling by outdoor temperature

Certified heating at 5, 17, and 47°F and cooling at 95°F for MDV-V18WMN10T, by outdoor temperature Heating: 18,000 Btu/h at 5°F, 15,100 Btu/h at 17°F, 18,000 Btu/h at 47°F. Cooling: 18,000 Btu/h at 95°F. The bars start at zero. Median of 1.5-ton central models: 11,200 Btu/h at 5°F, 12,600 Btu/h at 17°F, 18,000 Btu/h at 47°F, 18,000 Btu/h at 95°F. 0 5,000 10,000 15,000 20,000 Btu/h 18,000 5°F 15,100 17°F 18,000 47°F 18,000 95°F Outdoor temperature (°F)
  • Heating output
  • Cooling output
  • Median of 1.5-ton central models
  • Example heating load
  • Example cooling load
  • Frosting range, 17 to 45°F

This pairing delivers 18,000 Btu/h of heat at 47°F, 15,100 Btu/h at 17°F, and 18,000 Btu/h at 5°F, 100% of its 47°F rating. It delivers 18,000 Btu/h of cooling at 95°F. At 5°F that is 7,000 Btu/h above the example heating load of 11,000 Btu/h; at 95°F it is 12,500 Btu/h above the example cooling load of 5,500 Btu/h.

Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 1.5-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.

The dashed lines are example loads for a typical area of about 450 sq ft where winters reach 5°F: heating runs from 11,000 Btu/h at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 5,500 Btu/h at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.

Calculate heating and cooling for your house

AHRI certificate 216051341 · listed by Midea · certified Apr 22, 2026 · 1 pairing carries these values

Rebates where you live

Meets the recorded equipment thresholds of 69 programs in 37 states, provinces, or territories:Alabama (1), Arizona (1), California (3), Colorado (2), Connecticut (3), Delaware (1), Idaho (2), Illinois (1), Kansas (1), Kentucky (1), Maryland (3), Massachusetts (3), Michigan (2), Minnesota (3), Mississippi (2), Nevada (1), New Hampshire (3), New Jersey (7), New York (4), North Carolina (1), Oregon (2), Pennsylvania (4), Rhode Island (3), South Carolina (1), Tennessee (1), Texas (3), Utah (1), Vermont (3), Washington (3), Wisconsin (1), British Columbia (3), Manitoba (1), New Brunswick (1), Newfoundland and Labrador (1), Nova Scotia (2), Ontario (1), Yukon (2).

All 69 programs by state and province

Alabama

Arizona

California

Colorado

Connecticut

Delaware

Idaho

Illinois

Kansas

Kentucky

Maryland

Massachusetts

Michigan

Minnesota

Mississippi

Nevada

New Hampshire

New Jersey

New York

North Carolina

Oregon

Pennsylvania

Rhode Island

South Carolina

Tennessee

Texas

Utah

Vermont

Washington

Wisconsin

British Columbia

Manitoba

New Brunswick

Newfoundland and Labrador

Nova Scotia

Ontario

Yukon

Threshold comparisons use the unit’s median certified figures across its pairings, not the pairing selected above. Meeting these thresholds means the equipment may qualify; it does not guarantee approval. Service-area, installation, and product-list requirements also apply.

All rebate programs and their published thresholds

Certified output and power use

Certified output for the selected pairingThe four bars share one scale. The comparison is with the median of 1.5-ton central models. Heating tests run at 70°F indoors. The cooling test runs at 80°F indoors.
Outdoor temperature Certified outputBtu/h One scale vs class median COPat 5°F
5°Ffull speed 18,0005.28 kW +61% 1.95
17°Ffull speed 15,1004.43 kW +20% NR
47°Fnormal speed 18,0005.28 kW 0% NR
95°Fcooling, full load 18,0005.28 kW — NR

EER2 12.0 in that test. SEER2 17.1 over the modeled cooling season.

Power use at each temperature

Electrical input in the 5°F full-speed test
2.71kW
Electrical input in the 95°F cooling test
1.50kW
Seasonal average heating COP
2.71

These exclude backup resistance heat.

Updated Sep 19, 2026 · Methodology

How it compares with other 18,000 Btu heat pumps

1.5-ton central models

This pairing at 5°F
18,000 Btu/h
This unit at 5°F median across its pairings
18,000 Btu/h
Median of 1.5-ton central models at 5°F
11,200 Btu/h
Models in this group
243

This unit is above 74% of them, at number 63 of 243 by heat at 5°F. The middle half of the group runs 8,600 to 18,000 Btu/h.

This size class is defined by cooling capacity, so cooling is not compared here.

Among 18,000 Btu central models, each by its median certified pairing, highest first: 5°F output as a share of its 47°F rating, 60th of 243 (tied); HSPF2, 87th of 254. Models without that figure are left out.

Similar ratings at 47°F

These central models share the nominal cooling size. Comparisons use each model’s median certified figures across pairings.

  • MHP17L18P-**A: The same 18,000 Btu/h rating at 47°F; 8,700 Btu/h at 5°F (this model: 18,000).
  • A5HP5018A1: The same 18,000 Btu/h rating at 47°F; 9,000 Btu/h at 5°F (this model: 18,000).
  • DIRM4-18CS19-OU: The same 18,000 Btu/h rating at 47°F; 10,000 Btu/h at 5°F (this model: 18,000).

Closest models by heat at 5°F

Every 18,000 Btu (1.5-ton) unit, ranked by cooling efficiency, then heating efficiency

Floor area at the cold test point

The median certified output of 18,000 Btu/h at 5°F matches the size calculator’s heating estimate for these floor areas, rounded to about 10 sq ft. Each range divides that output by the climate band’s heating rates.

Floor area by climate band and house condition
Climate bandHouse conditionBtu/h per sq ftApproximate sq ft
MildDrafty, little insulation24–42430–750
MildTypical16–26690–1,130
MildTight, well insulated10–181,000–1,800
ColdDrafty, little insulation28–52350–640
ColdTypical18–30600–1,000
ColdTight, well insulated12–22820–1,500
Very coldDrafty, little insulation32–58310–560
Very coldTypical22–38470–820
Very coldTight, well insulated16–28640–1,130

This is an estimate, not a house-specific load calculation. Output stays at the 5°F test point for every band; it does not predict output at the band’s winter design temperature.

Certified values for MDV-V18WMN10T

8 pairings · 8 AHRI certificates

This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.

Certified values for MDV-V18WMN10T
This pairingAll pairings
Heating
Heat output at 47°F normal speed 18,000 Btu/h 18,000–20,000 Btu/h
Heat output at 17°F full speed 15,100 Btu/h 15,100–17,600 Btu/h
Heat output at 5°F full speed 18,000 Btu/h 14,400–18,000 Btu/h
Heat output below 5°F NR NR
Cold output 5°F output as a % of the 47°F rating 100%
COP at 5°F full speed 1.95 1.80–1.95
HSPF2 Region IV 9.3 8.7–10.0
Cooling
Cooling capacity at 95°F full-load test 18,000 Btu/h 18,000–18,200 Btu/h
EER2 at 95°F 12.0 10.5–12.0
SEER2 cooling season 17.1 15.2–17.5
Cooling at other temperatures NR NR
Equipment and listing
Refrigerant R-454B
Compressor Variable speed
Indoor unit MVME24B2MN10TB 5 indoor units
FurnaceNo furnace 1 furnace
Cold-climate designation EPA's designation, as published Yes On every pairing
ENERGY STAR Most Efficient EPA's designation, as published Yes On some pairings
Where it is sold US and Canada US and Canada
Model string as certified MDV-V18WMN10T

Across 8 certified pairings with 5 indoor models: heat at 5°F 14,400 Btu/h with MPCE18A1MN10TA to 18,000 Btu/h with MCPM3036BN10TH; HSPF2 8.7 with MPCE18A1MN10TA to 10.0; SEER2 15.2 with MCPM3036BN10TH to 17.5. Endpoints name one indoor model where recorded; the furnace pairing can also change the figures.

Pairings, by indoor-unit class

5 indoor units · 8 certified pairings

One row per indoor unit certified with this outdoor unit.

Furnace paired · 1 indoor unit

  1. MCPM3036BN10TH brand not stated 18,000 Btu/hat 5°F, full speed

    1 pairing, 1 with a furnace · 47°F 18,000 Btu/h · 95°F cooling 18,000 Btu/h · Cold output 100% · COP 1.90

Indoor units in the furnace paired class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · normal speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
MCPM3036BN10TH — 18,000 18,000 18,000 100% 1.90 Yes 1

Air handler · 4 indoor units

  1. MIH18VMN10 brand not stated 18,000 Btu/hat 5°F, full speed

    1 pairing · 47°F 18,000 Btu/h · 95°F cooling 18,000 Btu/h · Cold output 100% · COP 1.95

  2. MPCE18A1MN10TA brand not stated 14,400 Btu/hat 5°F, full speed

    1 pairing · 47°F 18,000 Btu/h · 95°F cooling 18,000 Btu/h · Cold output 80% · COP 1.80

  3. MPUE18A1MN10TA brand not stated 14,400 Btu/hat 5°F, full speed

    1 pairing · 47°F 18,000 Btu/h · 95°F cooling 18,000 Btu/h · Cold output 80% · COP 1.80

  4. MVME24B2MN10TB (the pairing on screen) brand not stated 18,000 Btu/hat 5°F, full speed

    1 pairing · 47°F 18,000 Btu/h · 95°F cooling 18,000 Btu/h · Cold output 100% · COP 1.95

Indoor units in the air handler class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · normal speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
MIH18VMN10 — 18,000 18,000 18,000 100% 1.95 Yes 1
MPCE18A1MN10TA — 14,400 18,000 18,000 80% 1.80 Yes 1
MPUE18A1MN10TA — 14,400 18,000 18,000 80% 1.80 Yes 1
MVME24B2MN10TB (the pairing on screen) — 18,000 18,000 18,000 100% 1.95 Yes 1

Ductless indoor

  1. None listed MIDEA 18,000 Btu/hat 5°F, full speed

    3 pairings · 47°F 20,000 Btu/h · 95°F cooling 18,200 Btu/h · Cold output 90% · COP 1.80

Indoor units in the ductless indoor class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · normal speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
None listed MIDEA 18,000 20,000 18,200 90% 1.80 Yes 3

The share is heat output at 5°F divided by the 47°F rating.

Showing 5 of 5 indoor units

Sold as, and units with identical certified values

Brands listing this model number

Model number as listed

Product history

  • MDV-V18WMN10T changed its certified heat output at 47°F on 3 pairings from 18,200 Btu/h to 20,000 Btu/h in the certified data between August 2025 and September 2026.
  • MDV-V18WMN10T first appeared in the certified data between March 2025 and May 2025.

History and definitions

Other ATOM X models by nominal cooling size: MDV-V24WMN10T (24,000 Btu), MDV-V24WMN10T(B) (24,000 Btu), MDV-V24WMN10T-H (24,000 Btu), MDV-V30WMN10T (30,000 Btu), MDV-V30WMN10T-H (30,000 Btu), MDV-V36WMN10T (36,000 Btu), MDV-V36WMN10T-H (36,000 Btu), MDV-V48WMN10T (48,000 Btu); more models from this brand.

Other MDV Series models by nominal cooling size: MDV-V24WMN10T (24,000 Btu), MDV-V24WMN10T(B) (24,000 Btu), MDV-V30WMN10T (30,000 Btu), MDV-V36WMN10T (36,000 Btu), MDV-V36WMN10T-H (36,000 Btu), MDV-V48WMN10T (48,000 Btu), MDV-V60WMN10T (54,000 Btu).

History

First certified record
Most recent certified record
Measurements reported
Apr 22, 2026
Status
In the certified data

Field definitions

COP
Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
HSPF2
Heating efficiency over a typical season. Higher uses less electricity.
SEER2
Cooling efficiency over a typical season. Higher uses less electricity.
EER2
Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
Cold output
Heat output at 5°F as a percentage of the 47°F rating.
% of rating at 17°F
Heat output at 17°F as a percentage of the 47°F rating.

NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read

Cite or print this page

Heat Pump List, “MDV-V18WMN10T — certified heat output”. Certified figures dated , checked daily.
https://heatpumplist.com/model/mdv-v18wmn10t