Heat Pump List

Tools

MDV-V36WMN10T

MDV-V36WMN10T is in the certified data.

Its certified full-speed heating output at 5°F is 28,800–36,000 Btu/h, 80–101% of its 47°F rating (tests at different compressor speeds), depending on the pairing.

Midea · central heat pump

MDV-V36WMN10T is in the certified data as of Sep 19, 2026. MDV-V36WMN10T changed its certified heat output at 47°F on 8 pairings in the certified data between August 2025 and September 2026. The new figure is higher on all 8.

11 certified pairings with 10 different figures. See all

Certified heating and cooling

Heating at 47°F

40,000

27,800 at 17°F

34,000 at 5°F

Btu/h, certified

2.00 COP at 5°F

Cooling at 95°F

36,000

Btu/h, certified

EER2 13.3 at 95°F

SEER2 20.0

Heating and cooling by outdoor temperature

Certified heating at 5, 17, and 47°F and cooling at 95°F for MDV-V36WMN10T, by outdoor temperature Heating: 34,000 Btu/h at 5°F, 27,800 Btu/h at 17°F, 40,000 Btu/h at 47°F. Cooling: 36,000 Btu/h at 95°F. The bars start at zero. Median of 3-ton central models: 26,400 Btu/h at 5°F, 26,200 Btu/h at 17°F, 35,200 Btu/h at 47°F, 35,000 Btu/h at 95°F. 0 10,000 20,000 30,000 40,000 Btu/h 34,000 5°F 27,800 17°F 40,000 47°F 36,000 95°F Outdoor temperature (°F)
  • Heating output
  • Cooling output
  • Median of 3-ton central models
  • Example heating load
  • Example cooling load
  • Frosting range, 17 to 45°F

This pairing delivers 40,000 Btu/h of heat at 47°F, 27,800 Btu/h at 17°F, and 34,000 Btu/h at 5°F, 85% of its 47°F rating. It delivers 36,000 Btu/h of cooling at 95°F. At 5°F that is 7,500 Btu/h above the example heating load of 26,500 Btu/h; at 95°F it is 23,000 Btu/h above the example cooling load of 13,000 Btu/h.

Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 3-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.

The dashed lines are example loads for a typical area of about 1,100 sq ft where winters reach 5°F: heating runs from 26,500 Btu/h at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 13,000 Btu/h at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.

Calculate heating and cooling for your house

AHRI certificate 216021077 · listed by Midea · certified Apr 17, 2026 · 1 pairing carries these values

All rebate programs and their published thresholds

Certified output and power use

Certified output for the selected pairingThe four bars share one scale. The comparison is with the median of 3-ton central models. Heating tests run at 70°F indoors. The cooling test runs at 80°F indoors.
Outdoor temperature Certified outputBtu/h One scale vs class median COPat 5°F
5°Ffull speed 34,0009.96 kW +29% 2.00
17°Ffull speed 27,8008.15 kW +6% NR
47°Fnormal speed 40,00011.72 kW +14% NR
95°Fcooling, full load 36,00010.55 kW — NR

EER2 13.3 in that test. SEER2 20.0 over the modeled cooling season.

Power use at each temperature

Electrical input in the 5°F full-speed test
4.98kW
Electrical input in the 95°F cooling test
2.71kW
Seasonal average heating COP
2.96

These exclude backup resistance heat.

Updated Sep 19, 2026 · Methodology

How it compares with other 36,000 Btu heat pumps

3-ton central models

This pairing at 5°F
34,000 Btu/h
This unit at 5°F median across its pairings
34,000 Btu/h
Median of 3-ton central models at 5°F
26,400 Btu/h
Models in this group
451

This unit is above 82% of them, at number 80 of 451 by heat at 5°F. The middle half of the group runs 18,650 to 32,000 Btu/h.

This size class is defined by cooling capacity, so cooling is not compared here.

Closest models by heat at 5°F

Every 36,000 Btu (3-ton) unit, ranked by cooling efficiency, then heating efficiency

Certified values for MDV-V36WMN10T

11 pairings · 11 AHRI certificates

This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.

Certified values for MDV-V36WMN10T
This pairingAll pairings
Heating
Heat output at 47°F normal speed 40,000 Btu/h 35,600–40,000 Btu/h
Heat output at 17°F full speed 27,800 Btu/h 27,800–32,000 Btu/h
Heat output at 5°F full speed 34,000 Btu/h 28,800–36,000 Btu/h
Heat output below 5°F NR NR
Cold output 5°F output as a % of the 47°F rating 85%
COP at 5°F full speed 2.00 1.80–2.00
HSPF2 Region IV 10.1 8.7–10.1
Cooling
Cooling capacity at 95°F full-load test 36,000 Btu/h 34,000–36,000 Btu/h
EER2 at 95°F 13.3 10.0–13.3
SEER2 cooling season 20.0 15.4–20.0
Cooling at other temperatures NR NR
Equipment and listing
Refrigerant R-454B
Compressor Variable speed
Indoor unit None listed 7 indoor units
FurnaceNo furnace 2 furnaces
Cold-climate designation EPA's designation, as published Yes On every pairing
ENERGY STAR Most Efficient EPA's designation, as published Yes On some pairings
Where it is sold US and Canada US and Canada
Model string as certified MDV-V36WMN10T

Pairings, by indoor-unit class

7 indoor units · 11 certified pairings

One row per indoor unit certified with this outdoor unit.

Furnace paired · 2 indoor units

  1. MCPM3036BN10TH brand not stated 36,000 Btu/hat 5°F, full speed

    2 pairings, 2 with a furnace · 47°F 35,800 Btu/h · 95°F cooling 34,000 Btu/h · Cold output 101% · COP 1.90

  2. MCPM3036BN10OH+TXV brand not stated 36,000 Btu/hat 5°F, full speed

    1 pairing, 1 with a furnace · 47°F 35,600 Btu/h · 95°F cooling 34,000 Btu/h · Cold output 101% · COP 1.90

Indoor units in the furnace paired class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · normal speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
MCPM3036BN10TH — 36,000 35,800 34,000 101% 1.90 Yes 2
MCPM3036BN10OH+TXV — 36,000 35,600 34,000 101% 1.90 Yes 1

Air handler · 5 indoor units

  1. MHVE36B1MN10TB brand not stated 28,800 Btu/hat 5°F, full speed

    1 pairing · 47°F 36,000 Btu/h · 95°F cooling 34,000 Btu/h · Cold output 80% · COP 1.80

  2. MIH36VMN10 brand not stated 36,000 Btu/hat 5°F, full speed

    1 pairing · 47°F 36,000 Btu/h · 95°F cooling 34,000 Btu/h · Cold output 100% · COP 1.90

  3. MPCE36B1MN10TA brand not stated 28,800 Btu/hat 5°F, full speed

    1 pairing · 47°F 36,000 Btu/h · 95°F cooling 34,000 Btu/h · Cold output 80% · COP 1.80

  4. MPUE36B1MN10TA brand not stated 28,800 Btu/hat 5°F, full speed

    1 pairing · 47°F 36,000 Btu/h · 95°F cooling 34,000 Btu/h · Cold output 80% · COP 1.80

  5. MVME36B2MN10TB brand not stated 36,000 Btu/hat 5°F, full speed

    1 pairing · 47°F 36,000 Btu/h · 95°F cooling 34,000 Btu/h · Cold output 100% · COP 1.90

Indoor units in the air handler class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · normal speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
MHVE36B1MN10TB — 28,800 36,000 34,000 80% 1.80 Yes 1
MIH36VMN10 — 36,000 36,000 34,000 100% 1.90 Yes 1
MPCE36B1MN10TA — 28,800 36,000 34,000 80% 1.80 Yes 1
MPUE36B1MN10TA — 28,800 36,000 34,000 80% 1.80 Yes 1
MVME36B2MN10TB — 36,000 36,000 34,000 100% 1.90 Yes 1

Ductless indoor

  1. None listed (the pairing on screen) MIDEA 34,000 Btu/hat 5°F, full speed

    3 pairings · 47°F 40,000 Btu/h · 95°F cooling 36,000 Btu/h · Cold output 85% · COP 2.00

Indoor units in the ductless indoor class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · normal speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
None listed (the pairing on screen) MIDEA 34,000 40,000 36,000 85% 2.00 Yes 3

The share is heat output at 5°F divided by the 47°F rating.

Showing 7 of 7 indoor units

Sold as, and units with identical certified values

Brands listing this model number

Model number as listed

Product history

  • MDV-V36WMN10T changed its certified heat output at 47°F on 8 pairings in the certified data between August 2025 and September 2026. The new figure is higher on all 8.
  • MDV-V36WMN10T first appeared in the certified data between March 2025 and May 2025.

History and definitions

History

First certified record
Most recent certified record
Measurements reported
Apr 17, 2026
Status
In the certified data

Field definitions

COP
Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
HSPF2
Heating efficiency over a typical season. Higher uses less electricity.
SEER2
Cooling efficiency over a typical season. Higher uses less electricity.
EER2
Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
Cold output
Heat output at 5°F as a percentage of the 47°F rating.
% of rating at 17°F
Heat output at 17°F as a percentage of the 47°F rating.

NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read

Cite or print this page

Heat Pump List, “MDV-V36WMN10T — certified heat output”. Certified figures dated , checked daily.
https://heatpumplist.com/model/mdv-v36wmn10t