MMCMRAQ18BA3
Midea · mini-split heat pump
MMCMRAQ18BA3 is in the certified data as of Sep 19, 2026.
- 18,000 Btu (1.5-ton)
- Mini-split
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
19,0005.57NR
No 47°F rating for this pairing.
14,5004.25NR at 17°F
12,9003.78NR at 5°F
Btu/hkW, certified
2.00NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 19,000 Btu/h5.57 kW of heat at 47°F, 14,500 Btu/h4.25 kW at 17°F, and 12,900 Btu/h3.78 kW at 5°F, 68% of its 47°F rating. It delivers 18,000 Btu/h5.28 kW of cooling at 95°F. At 5°F that is 1,100 Btu/h0.32 kW short of the example heating load of 14,000 Btu/h4.10 kW; at 95°F it is 11,000 Btu/h3.22 kW above the example cooling load of 7,000 Btu/h2.05 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 1.5-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 600 sq ft where winters reach 5°F: heating runs from 14,000 Btu/h4.10 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 7,000 Btu/h2.05 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 207683473 · listed by Midea · certified Jun 25, 2026 · 1 pairing carries these values
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 12,9003.78 kW | −9% | 2.00 | |
| 17°Ffull speed | 14,5004.25 kW | −2% | NR | |
| 47°Fnormal speed | 19,0005.57 kW | +6% | NR | |
| 95°Fcooling, full load | 18,0005.28 kW | — | NR |
EER2 12.95 in that test. SEER2 20.95 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 1.89kW
- Electrical input in the 95°F cooling test
- 1.39kW
- Seasonal average heating COP
- 2.97
These exclude backup resistance heat.
How it compares with other 18,000 Btu heat pumps
1.5-ton mini-split models
- This pairing at 5°F
- 12,900 Btu/h3.78 kWNR
- This unit at 5°F median across its pairings
- 12,900 Btu/h3.78 kW
- Median of 1.5-ton mini-split models at 5°F
- 14,200 Btu/h4.16 kW
- Models in this group
- 1,110
This unit is above 20% of them, at number 891 of 1,110 by heat at 5°F. The middle half of the group runs 13,000 to 18,000 Btu/h.
Closest models by heat at 5°F
- ZMSB-18HV-USHHR2-OZero · 13,000 Btu/h
- H18SVH20XQCTCL · 12,900 Btu/h
- M2OA-18HFN1-MAlsetria, Eco Air + 1 more · 12,900 Btu/h
- YN020GMFI22M2EPioneer · 12,900 Btu/h
- 1U18EH2VHEHaier · 12,800 Btu/h
- AOX430-18HFN1-MT8WAC Pro · 12,800 Btu/h
Every 18,000 Btu (1.5-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for MMCMRAQ18BA3
3 pairings · 3 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 19,000 Btu/h5.57 kWNR | 19,000 Btu/h5.57 kW |
| Heat output at 17°F full speed | 14,500 Btu/h4.25 kWNR | 14,300–14,800 Btu/h4.19–4.34 kW |
| Heat output at 5°F full speed | 12,900 Btu/h3.78 kWNR | 12,600–13,300 Btu/h3.69–3.90 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 68%NR | |
| COP at 5°F full speed | 2.00NR | 2.00 |
| HSPF2 Region IV | 10.2NR | 9.8–10.5 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 18,000 Btu/h5.28 kWNR | 18,000 Btu/h5.28 kW |
| EER2 at 95°F | 12.95NR | 12.0–13.9 |
| SEER2 cooling season | 20.95NR | 19.0–22.9 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-410A | |
| Compressor | Variable speed | |
| Indoor unit | None listed | None |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | NC | On some pairings |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On every pairing |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | MMCMRAQ18BA3 | |
Pairings, by indoor-unit class
3 certified pairings
One row per indoor unit certified with this outdoor unit.
Ductless indoor
-
None listed (the pairing on screen) MIDEA 12,900 Btu/h3.78 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| None listed (the pairing on screen) | MIDEA | 12,9003.78 | 19,0005.57 | 18,0005.28 | 68% | 2.00 | Yes | 3 |
Sold as, and units with identical certified values
Variants of the same model number
21 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
- 18MPC2-XX-AMulti MFG
- 38MGRBQ18BA3Bryant · Carrier · Midea · Payne · WeatherMaker
- 4DHP2S18M-1PAirEase · Allied · Armstrong Air · Concord · Ducane
- A2OA-18HFN1-MAC Pro
- BMS500-AAM018-1CSXRCBosch
- BZ33-HP182Z2-G2-PBreeze33
- C28MC218H21CanAir
- CH-18MES-230VOC&H · Cooper&Hunter
- CMZ-18-2ZComfortStar
- DEA18HOM23230X2Elios
- DIRM-18DA25-2ZDirect Air
- DMA18HOM23230X2MoovAir
- ES-18Z-M2B1HVAC · ACiQ · DIYCool · PolarWave · Stealth
- KO-PS218HP-2AAMAKaden
- M2OA-18HFN1-M-LMDV
- M2S18H/O4S4PTrust Air Conditioners
- MPC018S4M-1PLennox
- MULTI2-18HP230BMRCOOL
- ODUM2OA-18HFN1-MKepler
- SENA/18HF/MOQSenville
20 of 21 shown.
Other model numbers with identical certified values
11 units share this record. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
- 18MPC2-XX-Aidentical certified values
- A2OA-18HFN1-Midentical certified values
- BZ33-HP182Z2-G2-Pidentical certified values
- C28MC218H21identical certified values
- DEA18HOM23230X2identical certified values
- KO-PS218HP-2AAMAidentical certified values
- M2OA-18HFN1-M-Lidentical certified values
- M2S18H/O4S4Pidentical certified values
- MPC018S4M-1Pidentical certified values
- ODUM2OA-18HFN1-Midentical certified values
10 of 11 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Jun 25, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read