MOD30-24HFN1-MU0W
MOD30-24HFN1-MU0W is in the certified data.
Its certified full-speed heating output at 5°F is 21,200–27,000 Btu/h6.21–7.91 kW, 81–108% of its 47°F rating (tests at different compressor speeds), depending on the pairing.
Alsetria, Direct Air + 2 more · mini-split heat pump
MOD30-24HFN1-MU0W is in the certified data as of Sep 19, 2026.
- 24,000 Btu (2-ton)
- Mini-split
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
29,0008.50NR
No 47°F rating for this pairing.
21,2006.21NR at 17°F
25,0007.33NR at 5°F
Btu/hkW, certified
2.21NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 29,000 Btu/h8.50 kW of heat at 47°F, 21,200 Btu/h6.21 kW at 17°F, and 25,000 Btu/h7.33 kW at 5°F, 86% of its 47°F rating. It delivers 24,000 Btu/h7.03 kW of cooling at 95°F. At 5°F that is 6,000 Btu/h1.76 kW above the example heating load of 19,000 Btu/h5.57 kW; at 95°F it is 14,500 Btu/h4.25 kW above the example cooling load of 9,500 Btu/h2.78 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 2-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 800 sq ft where winters reach 5°F: heating runs from 19,000 Btu/h5.57 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 9,500 Btu/h2.78 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 205993855 · listed by MDV · certified Jun 13, 2026 · 3 pairings share these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 25,0007.33 kW | +32% | 2.21 | |
| 17°Ffull speed | 21,2006.21 kW | +6% | NR | |
| 47°Fnormal speed | 29,0008.50 kW | +16% | NR | |
| 95°Fcooling, full load | 24,0007.03 kW | — | NR |
EER2 13.0 in that test. SEER2 21.5 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 3.32kW
- Electrical input in the 95°F cooling test
- 1.85kW
- Seasonal average heating COP
- 3.34
These exclude backup resistance heat.
How it compares with other 24,000 Btu heat pumps
2-ton mini-split models
- This pairing at 5°F
- 25,000 Btu/h7.33 kWNR
- This unit at 5°F median across its pairings
- 25,000 Btu/h7.33 kW
- Median of 2-ton mini-split models at 5°F
- 19,000 Btu/h5.57 kW
- Models in this group
- 917
This unit is above 87% of them, at number 117 of 917 by heat at 5°F. The middle half of the group runs 18,000 to 23,000 Btu/h.
Closest models by heat at 5°F
- MHSZ124DAConforto and EMI · 25,000 Btu/h
- MLB024S4S-1PLennox · 25,000 Btu/h
- MMLD024S6M-1PLennox · 25,000 Btu/h
- MOD30-24HFN1-MU0W-LMDV · 25,000 Btu/h
- MSH243F25MCAAFranklin · 25,000 Btu/h
- MXZ-3C24NAHZ3Mitsubishi Electric · 25,000 Btu/h
Every 24,000 Btu (2-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for MOD30-24HFN1-MU0W
19 pairings · 19 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 29,000 Btu/h8.50 kWNR | 23,400–29,000 Btu/h6.86–8.50 kW |
| Heat output at 17°F full speed | 21,200 Btu/h6.21 kWNR | 16,500–22,000 Btu/h4.84–6.45 kW |
| Heat output at 5°F full speed | 25,000 Btu/h7.33 kWNR | 21,200–27,000 Btu/h6.21–7.91 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 86%NR | |
| COP at 5°F full speed | 2.21NR | 1.70–2.21 |
| HSPF2 Region IV | 11.4NR | 8.5–11.5 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 24,000 Btu/h7.03 kWNR | 21,600–24,000 Btu/h6.33–7.03 kW |
| EER2 at 95°F | 13.0NR | 11.0–13.0 |
| SEER2 cooling season | 21.5NR | 15.2–22.3 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-410A | |
| Compressor | Variable speed | |
| Indoor unit | MSEPD-24HRFN1-MU0W | 10 indoor units |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | Yes | On some pairings |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On some pairings |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | MOD30-24HFN1-MU0W | |
Pairings, by indoor-unit class
10 indoor units · 19 certified pairings
One row per indoor unit certified with this outdoor unit.
Air handler · 3 indoor units
-
MVC-23HWFN1-M (the pairing on screen) brand not stated 21,200 Btu/h6.21 kWat 5°F, full speed
-
MAC-24HWDN1-MN0-N (the pairing on screen) brand not stated 23,000 Btu/h6.74 kWat 5°F, full speed
-
MVB-24HWFN1-M (the pairing on screen) brand not stated 22,000 Btu/h6.45 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| MVC-23HWFN1-M (the pairing on screen) | — | 21,2006.21 | 26,0007.62 | 23,0006.74 | 82% | 1.90 | Yes | 3 |
| MAC-24HWDN1-MN0-N (the pairing on screen) | — | 23,0006.74 | 24,6007.21 | 23,0006.74 | 93% | 2.08 | Yes | 1 |
| MVB-24HWFN1-M (the pairing on screen) | — | 22,0006.45 | 27,0007.91 | 22,0006.45 | 81% | 1.70 | NC | 1 |
Ductless indoor · 7 indoor units
-
MCD1-24HRFN1-MT0W(GA) (the pairing on screen) Alsetria 25,800 Btu/h7.56 kWat 5°F, full speed
-
MSEPD-24HRFN1-MU0W (the pairing on screen) Alsetria 25,000 Btu/h7.33 kWat 5°F, full speed
-
MTIU-24HWFN1-M (the pairing on screen) Alsetria 27,000 Btu/h7.91 kWat 5°F, full speed
-
CS11M-23HRFN1-MT0W (the pairing on screen) DIRECT AIR 23,400 Btu/h6.86 kWat 5°F, full speed
-
MSAG11D-23HRFN1-MU0W (the pairing on screen) MDV 23,000 Btu/h6.74 kWat 5°F, full speed
-
MTI-24HWFN1-MSP5 (the pairing on screen) MDV 24,000 Btu/h7.03 kWat 5°F, full speed
-
MUEU-24HRFN1-M(C) (the pairing on screen) MDV 25,000 Btu/h7.33 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| MCD1-24HRFN1-MT0W(GA) (the pairing on screen) | Alsetria | 25,8007.56 | 25,0007.33 | 24,0007.03 | 103% | 2.00 | Yes | 3 |
| MSEPD-24HRFN1-MU0W (the pairing on screen) | Alsetria | 25,0007.33 | 29,0008.50 | 24,0007.03 | 86% | 2.21 | Yes | 3 |
| MTIU-24HWFN1-M (the pairing on screen) | Alsetria | 27,0007.91 | 25,0007.33 | 24,0007.03 | 108% | 2.00 | Yes | 3 |
| CS11M-23HRFN1-MT0W (the pairing on screen) | DIRECT AIR | 23,4006.86 | 23,4006.86 | 21,6006.33 | 100% | 1.89 | Yes | 2 |
| MSAG11D-23HRFN1-MU0W (the pairing on screen) | MDV | 23,0006.74 | 26,0007.62 | 23,0006.74 | 88% | 1.80 | Yes | 1 |
| MTI-24HWFN1-MSP5 (the pairing on screen) | MDV | 24,0007.03 | 25,0007.33 | 24,0007.03 | 96% | 2.00 | Yes | 1 |
| MUEU-24HRFN1-M(C) (the pairing on screen) | MDV | 25,0007.33 | 25,0007.33 | 24,0007.03 | 100% | 2.10 | Yes | 1 |
Sold as, and units with identical certified values
Brands listing this model number
Other brands that list these model numbers
- Are Alsetria and Eco Air heat pumps the same?33 shared model numbers
- Are Alsetria and MDV heat pumps the same?33 shared model numbers
- Are Eco Air and MDV heat pumps the same?36 shared model numbers
Model number as listed
- MOD30-24HFN1-MU0W 19 pairings
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Jun 13, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read