MOE31U-36HFN1-M
MOE31U-36HFN1-M is in the certified data.
Its certified full-speed heating output at 5°F is 31,600–36,000 Btu/h9.26–10.55 kW, 82–100% of its 47°F rating (tests at different compressor speeds), depending on the pairing.
Alsetria, CanAir + 4 more · central heat pump
MOE31U-36HFN1-M is in the certified data as of Sep 19, 2026.
- 36,000 Btu (3-ton)
- Central
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
39,00011.43NR
No 47°F rating for this pairing.
33,0009.67NR at 17°F
32,0009.38NR at 5°F
Btu/hkW, certified
2.00NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 39,000 Btu/h11.43 kW of heat at 47°F, 33,000 Btu/h9.67 kW at 17°F, and 32,000 Btu/h9.38 kW at 5°F, 82% of its 47°F rating. It delivers 35,000 Btu/h10.26 kW of cooling at 95°F. At 5°F that is 5,500 Btu/h1.61 kW above the example heating load of 26,500 Btu/h7.77 kW; at 95°F it is 22,000 Btu/h6.45 kW above the example cooling load of 13,000 Btu/h3.81 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 3-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 1,100 sq ft where winters reach 5°F: heating runs from 26,500 Btu/h7.77 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 13,000 Btu/h3.81 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 208101914 · listed by MDV · certified Jun 9, 2026 · 6 pairings share these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 32,0009.38 kW | +21% | 2.00 | |
| 17°Ffull speed | 33,0009.67 kW | +26% | NR | |
| 47°Fnormal speed | 39,00011.43 kW | +11% | NR | |
| 95°Fcooling, full load | 35,00010.26 kW | — | NR |
EER2 10.0 in that test. SEER2 15.2 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 4.69kW
- Electrical input in the 95°F cooling test
- 3.50kW
- Seasonal average heating COP
- 2.93
These exclude backup resistance heat.
How it compares with other 36,000 Btu heat pumps
3-ton central models
- This pairing at 5°F
- 32,000 Btu/h9.38 kWNR
- This unit at 5°F median across its pairings
- 32,000 Btu/h9.38 kW
- Median of 3-ton central models at 5°F
- 26,400 Btu/h7.74 kW
- Models in this group
- 451
This unit is above 70% of them, at number 135 of 451 by heat at 5°F. The middle half of the group runs 18,650 to 32,000 Btu/h.
Closest models by heat at 5°F
- ECUO-33HEco Air · 32,000 Btu/h
- MHSD136DACFCConforto and EMI · 32,000 Btu/h
- MO1HE-H36B-2AMidea · 32,000 Btu/h
- AC036BXUDCHSamsung · 31,600 Btu/h
- AZPN/36WACKepler · 31,600 Btu/h
- RP17AY36AJVCRheem and Ruud · 31,000 Btu/h
Every 36,000 Btu (3-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for MOE31U-36HFN1-M
19 pairings · 19 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 39,000 Btu/h11.43 kWNR | 36,000–40,000 Btu/h10.55–11.72 kW |
| Heat output at 17°F full speed | 33,000 Btu/h9.67 kWNR | 27,400–33,000 Btu/h8.03–9.67 kW |
| Heat output at 5°F full speed | 32,000 Btu/h9.38 kWNR | 31,600–36,000 Btu/h9.26–10.55 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 82%NR | |
| COP at 5°F full speed | 2.00NR | 1.81–2.00 |
| HSPF2 Region IV | 10.0NR | 8.6–10.0 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 35,000 Btu/h10.26 kWNR | 35,000–36,000 Btu/h10.26–10.55 kW |
| EER2 at 95°F | 10.0NR | 10.0–10.2 |
| SEER2 cooling season | 15.2NR | 15.2–17.6 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-410A | |
| Compressor | Variable speed | |
| Indoor unit | MAC-36HWDN1-MN0 | 6 indoor units |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | No | On some pairings |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | MOE31U-36HFN1-M | |
Pairings, by indoor-unit class
6 indoor units · 19 certified pairings
One row per indoor unit certified with this outdoor unit.
Air handler · 6 indoor units
-
MVB-36B23T4N1 (the pairing on screen) brand not stated 31,600 Btu/h9.26 kWat 5°F, full speed
-
MVC-36HWFN1-M (the pairing on screen) brand not stated 34,400 Btu/h10.08 kWat 5°F, full speed
-
MAC-36HWDN1-MN0 (the pairing on screen) brand not stated 32,000 Btu/h9.38 kWat 5°F, full speed
-
MAC-36HWFN1-M (the pairing on screen) brand not stated 32,000 Btu/h9.38 kWat 5°F, full speed
-
MVBE-36HWFN1-ML3E (the pairing on screen) brand not stated 33,400 Btu/h9.79 kWat 5°F, full speed
-
MVBL-36HWFN1-MK3 (the pairing on screen) brand not stated 36,000 Btu/h10.55 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| MVB-36B23T4N1 (the pairing on screen) | — | 31,6009.26 | 38,00011.14 | 35,00010.26 | 83% | 1.85 | Yes | 4 |
| MVC-36HWFN1-M (the pairing on screen) | — | 34,40010.08 | 40,00011.72 | 36,00010.55 | 86% | 1.97 | Yes | 4 |
| MAC-36HWDN1-MN0 (the pairing on screen) | — | 32,0009.38 | 39,00011.43 | 35,00010.26 | 82% | 2.00 | Yes | 3 |
| MAC-36HWFN1-M (the pairing on screen) | — | 32,0009.38 | 39,00011.43 | 35,00010.26 | 82% | 2.00 | Yes | 3 |
| MVBE-36HWFN1-ML3E (the pairing on screen) | — | 33,4009.79 | 38,00011.14 | 36,00010.55 | 88% | 1.81 | Yes | 3 |
| MVBL-36HWFN1-MK3 (the pairing on screen) | — | 36,00010.55 | 36,00010.55 | 36,00010.55 | 100% | 1.90 | Yes | 2 |
Sold as, and units with identical certified values
Brands listing this model number
- Alsetria3 pairings
- CanAir1 pairing
- Eco Air5 pairings
- MDV5 pairings
- Midea1 pairing
- Mits Air4 pairings
Other brands that list these model numbers
- Are Alsetria and Eco Air heat pumps the same?33 shared model numbers
- Are Alsetria and MDV heat pumps the same?33 shared model numbers
- Are Alsetria and Midea heat pumps the same?15 shared model numbers
- Are Eco Air and MDV heat pumps the same?36 shared model numbers
- Are Eco Air and Midea heat pumps the same?15 shared model numbers
- Are MDV and Midea heat pumps the same?26 shared model numbers
Model number as listed
- MOE31U-36HFN1-M 19 pairings
Variants of the same model number
3 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
2 of 3 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Jun 9, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read