MOVA-18HN10-M152L
MOVA-18HN10-M152L is in the certified data.
Its certified full-speed heating output at 5°F is 7,200–7,600 Btu/h2.11–2.23 kW, 42–46% of its 47°F rating, depending on the pairing.
Midea · central heat pump
MOVA-18HN10-M152L is in the certified data as of Sep 19, 2026.
- 18,000 Btu (1.5-ton)
- Central
- Single stage
- US and Canada
Certified heating and cooling
Heating at 47°F
17,2005.04NR
No 47°F rating for this pairing.
10,0002.93NR at 17°F
7,5002.20NR at 5°F
Btu/hkW, certified
1.88NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 17,200 Btu/h5.04 kW of heat at 47°F, 10,000 Btu/h2.93 kW at 17°F, and 7,500 Btu/h2.20 kW at 5°F, 44% of its 47°F rating. It delivers 18,000 Btu/h5.28 kW of cooling at 95°F. At 5°F that is 3,500 Btu/h1.03 kW short of the example heating load of 11,000 Btu/h3.22 kW; at 95°F it is 12,500 Btu/h3.66 kW above the example cooling load of 5,500 Btu/h1.61 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at one speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 1.5-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 450 sq ft where winters reach 5°F: heating runs from 11,000 Btu/h3.22 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 5,500 Btu/h1.61 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 215493872 · listed by Midea · certified Mar 31, 2025 · 2 pairings share these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Fone compressor speed | 7,5002.20 kW | −33% | 1.88 | |
| 17°Fone compressor speed | 10,0002.93 kW | −21% | NR | |
| 47°Fone compressor speed | 17,2005.04 kW | −4% | NR | |
| 95°Fcooling, full load | 18,0005.28 kW | — | NR |
EER2 12.0 in that test. SEER2 15.2 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 1.17kW
- Electrical input in the 95°F cooling test
- 1.50kW
- Seasonal average heating COP
- 2.29
These exclude backup resistance heat.
How it compares with other 18,000 Btu heat pumps
1.5-ton central models
- This pairing at 5°F
- 7,500 Btu/h2.20 kWNR
- This unit at 5°F median across its pairings
- 7,500 Btu/h2.20 kW
- Median of 1.5-ton central models at 5°F
- 11,200 Btu/h3.28 kW
- Models in this group
- 243
This unit is above 0% of them, at number 242 of 243 by heat at 5°F. The middle half of the group runs 8,600 to 18,000 Btu/h.
Closest models by heat at 5°F
- THF2B18S21Champion, Coleman + 3 more · 8,100 Btu/h
- HRG1**8S1R-**ACentury and Comfort-Aire · 8,000 Btu/h
- GLZS5BA1810AGoodman · 7,800 Btu/h
- GSZH501810AGoodman · 7,800 Btu/h
- J5HP5018A1000AAOXBOX · 7,500 Btu/h
- SPHP-M-1018BBAC Pro · 7,300 Btu/h
Every 18,000 Btu (1.5-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for MOVA-18HN10-M152L
14 pairings · 14 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F one speed | 17,200 Btu/h5.04 kWNR | 16,500–18,000 Btu/h4.84–5.28 kW |
| Heat output at 17°F full speed | 10,000 Btu/h2.93 kWNR | 10,000–10,100 Btu/h2.93–2.96 kW |
| Heat output at 5°F full speed | 7,500 Btu/h2.20 kWNR | 7,200–7,600 Btu/h2.11–2.23 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 44%NR | |
| COP at 5°F full speed | 1.88NR | 1.88–1.94 |
| HSPF2 Region IV | 7.8NR | 7.8 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 18,000 Btu/h5.28 kWNR | 18,000 Btu/h5.28 kW |
| EER2 at 95°F | 12.0NR | 12.0 |
| SEER2 cooling season | 15.2NR | 15.2 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-454B | |
| Compressor | Single stage | |
| Indoor unit | MVME24A1MN10OA+TXV | 14 indoor units |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | NC | NC |
| ENERGY STAR Most Efficient EPA's designation, as published | No | On no pairings |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | MOVA-18HN10-M152L | |
Pairings, by indoor-unit class
14 indoor units · 14 certified pairings
One row per indoor unit certified with this outdoor unit.
Air handler · 14 indoor units
-
MHVE18A1MN10TB (the pairing on screen) brand not stated 7,200 Btu/h2.11 kWat 5°F, full speed
-
MHVE24A1MN10TB (the pairing on screen) brand not stated 7,200 Btu/h2.11 kWat 5°F, full speed
-
MPCE30B1MN10TA (the pairing on screen) brand not stated 7,300 Btu/h2.14 kWat 5°F, full speed
-
MPCE30B2MN10TA (the pairing on screen) brand not stated 7,600 Btu/h2.23 kWat 5°F, full speed
-
MPCE36B1MN10TA (the pairing on screen) brand not stated 7,300 Btu/h2.14 kWat 5°F, full speed
-
MPCE36B2MN10TA (the pairing on screen) brand not stated 7,600 Btu/h2.23 kWat 5°F, full speed
-
MPUE30B1MN10TA (the pairing on screen) brand not stated 7,300 Btu/h2.14 kWat 5°F, full speed
-
MPUE30B2MN10TA (the pairing on screen) brand not stated 7,600 Btu/h2.23 kWat 5°F, full speed
-
MPUE36B1MN10TA (the pairing on screen) brand not stated 7,300 Btu/h2.14 kWat 5°F, full speed
-
MPUE36B2MN10TA (the pairing on screen) brand not stated 7,600 Btu/h2.23 kWat 5°F, full speed
-
MVME24A1MN10OA+TXV (the pairing on screen) brand not stated 7,500 Btu/h2.20 kWat 5°F, full speed
-
MVME24A1MN10TA (the pairing on screen) brand not stated 7,500 Btu/h2.20 kWat 5°F, full speed
-
MVME36B1MN10OA+TXV (the pairing on screen) brand not stated 7,500 Btu/h2.20 kWat 5°F, full speed
-
MVME36B1MN10TA (the pairing on screen) brand not stated 7,500 Btu/h2.20 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · one speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| MHVE18A1MN10TB (the pairing on screen) | — | 7,2002.11 | 16,5004.84 | 18,0005.28 | 44% | 1.88 | NC | 1 |
| MHVE24A1MN10TB (the pairing on screen) | — | 7,2002.11 | 17,3005.07 | 18,0005.28 | 42% | 1.88 | NC | 1 |
| MPCE30B1MN10TA (the pairing on screen) | — | 7,3002.14 | 16,6004.86 | 18,0005.28 | 44% | 1.90 | NC | 1 |
| MPCE30B2MN10TA (the pairing on screen) | — | 7,6002.23 | 16,6004.86 | 18,0005.28 | 46% | 1.94 | NC | 1 |
| MPCE36B1MN10TA (the pairing on screen) | — | 7,3002.14 | 16,6004.86 | 18,0005.28 | 44% | 1.88 | NC | 1 |
| MPCE36B2MN10TA (the pairing on screen) | — | 7,6002.23 | 16,6004.86 | 18,0005.28 | 46% | 1.94 | NC | 1 |
| MPUE30B1MN10TA (the pairing on screen) | — | 7,3002.14 | 16,5004.84 | 18,0005.28 | 44% | 1.90 | NC | 1 |
| MPUE30B2MN10TA (the pairing on screen) | — | 7,6002.23 | 16,6004.86 | 18,0005.28 | 46% | 1.94 | NC | 1 |
| MPUE36B1MN10TA (the pairing on screen) | — | 7,3002.14 | 16,5004.84 | 18,0005.28 | 44% | 1.88 | NC | 1 |
| MPUE36B2MN10TA (the pairing on screen) | — | 7,6002.23 | 16,6004.86 | 18,0005.28 | 46% | 1.94 | NC | 1 |
| MVME24A1MN10OA+TXV (the pairing on screen) | — | 7,5002.20 | 17,2005.04 | 18,0005.28 | 44% | 1.88 | NC | 1 |
| MVME24A1MN10TA (the pairing on screen) | — | 7,5002.20 | 17,2005.04 | 18,0005.28 | 44% | 1.88 | NC | 1 |
| MVME36B1MN10OA+TXV (the pairing on screen) | — | 7,5002.20 | 18,0005.28 | 18,0005.28 | 42% | 1.90 | NC | 1 |
| MVME36B1MN10TA (the pairing on screen) | — | 7,5002.20 | 18,0005.28 | 18,0005.28 | 42% | 1.90 | NC | 1 |
Sold as, and units with identical certified values
Brands listing this model number
Model number as listed
- MOVA-18HN10-M152L 14 pairings
Variants of the same model number
2 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
1 of 2 shown.
Other model numbers with identical certified values
2 units share this record. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
1 of 2 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Mar 31, 2025
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read