MOVC-18HN10-M152L is in the certified data as of Sep 19, 2026.

14 certified pairings with 9 different figures. See all

Certified heating and cooling

Heating at 47°F

17,200

10,000 at 17°F

7,500 at 5°F

Btu/h, certified

1.88 COP at 5°F

Cooling at 95°F

18,000

Btu/h, certified

EER2 12.0 at 95°F

SEER2 15.2

Heating and cooling by outdoor temperature

Certified heating at 5, 17, and 47°F and cooling at 95°F for MOVC-18HN10-M152L, by outdoor temperature Heating: 7,500 Btu/h at 5°F, 10,000 Btu/h at 17°F, 17,200 Btu/h at 47°F. Cooling: 18,000 Btu/h at 95°F. The bars start at zero. Median of 1.5-ton central models: 11,200 Btu/h at 5°F, 12,600 Btu/h at 17°F, 18,000 Btu/h at 47°F, 18,000 Btu/h at 95°F. 0 5,000 10,000 15,000 20,000 Btu/h 7,500 5°F 10,000 17°F 17,200 47°F 18,000 95°F Outdoor temperature (°F)
  • Heating output
  • Cooling output
  • Median of 1.5-ton central models
  • Example heating load
  • Example cooling load
  • Frosting range, 17 to 45°F

This pairing delivers 17,200 Btu/h of heat at 47°F, 10,000 Btu/h at 17°F, and 7,500 Btu/h at 5°F, 44% of its 47°F rating. It delivers 18,000 Btu/h of cooling at 95°F. At 5°F that is 3,500 Btu/h short of the example heating load of 11,000 Btu/h; at 95°F it is 12,500 Btu/h above the example cooling load of 5,500 Btu/h.

Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at one speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 1.5-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.

The dashed lines are example loads for a typical area of about 450 sq ft where winters reach 5°F: heating runs from 11,000 Btu/h at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 5,500 Btu/h at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.

Calculate heating and cooling for your house

AHRI certificate 217508482 · listed by Midea · certified Jun 18, 2025 · 2 pairings share these values

Certified output and power use

Certified output for the selected pairingThe four bars share one scale. The comparison is with the median of 1.5-ton central models. Heating tests run at 70°F indoors. The cooling test runs at 80°F indoors.
Outdoor temperature Certified outputBtu/h One scale vs class median COPat 5°F
5°Fone compressor speed 7,5002.20 kW −33% 1.88
17°Fone compressor speed 10,0002.93 kW −21% NR
47°Fone compressor speed 17,2005.04 kW −4% NR
95°Fcooling, full load 18,0005.28 kW — NR

EER2 12.0 in that test. SEER2 15.2 over the modeled cooling season.

Power use at each temperature

Electrical input in the 5°F full-speed test
1.17kW
Electrical input in the 95°F cooling test
1.50kW
Seasonal average heating COP
2.29

These exclude backup resistance heat.

Updated Sep 19, 2026 · Methodology

How it compares with other 18,000 Btu heat pumps

1.5-ton central models

This pairing at 5°F
7,500 Btu/h
This unit at 5°F median across its pairings
7,500 Btu/h
Median of 1.5-ton central models at 5°F
11,200 Btu/h
Models in this group
243

This unit is above 0% of them, at number 242 of 243 by heat at 5°F. The middle half of the group runs 8,600 to 18,000 Btu/h.

This size class is defined by cooling capacity, so cooling is not compared here.

Closest models by heat at 5°F

Every 18,000 Btu (1.5-ton) unit, ranked by cooling efficiency, then heating efficiency

Certified values for MOVC-18HN10-M152L

14 pairings · 14 AHRI certificates

This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.

Certified values for MOVC-18HN10-M152L
This pairingAll pairings
Heating
Heat output at 47°F one speed 17,200 Btu/h 16,500–18,000 Btu/h
Heat output at 17°F full speed 10,000 Btu/h 10,000–10,100 Btu/h
Heat output at 5°F full speed 7,500 Btu/h 7,200–7,600 Btu/h
Heat output below 5°F NR NR
Cold output 5°F output as a % of the 47°F rating 44%
COP at 5°F full speed 1.88 1.88–1.94
HSPF2 Region IV 7.8 7.8
Cooling
Cooling capacity at 95°F full-load test 18,000 Btu/h 18,000 Btu/h
EER2 at 95°F 12.0 12.0
SEER2 cooling season 15.2 15.2
Cooling at other temperatures NR NR
Equipment and listing
Refrigerant R-454B
Compressor Single stage
Indoor unit MVME24A1MN10OA+TXV 14 indoor units
FurnaceNo furnace None
Cold-climate designation EPA's designation, as published NC NC
ENERGY STAR Most Efficient EPA's designation, as published No On no pairings
Where it is sold US and Canada US and Canada
Model string as certified MOVC-18HN10-M152L

Pairings, by indoor-unit class

14 indoor units · 14 certified pairings

One row per indoor unit certified with this outdoor unit.

Air handler · 14 indoor units

  1. MHVE18A1MN10TB brand not stated 7,200 Btu/hat 5°F, full speed

    1 pairing · 47°F 16,500 Btu/h · 95°F cooling 18,000 Btu/h · Cold output 44% · COP 1.88

  2. MHVE24A1MN10TB brand not stated 7,200 Btu/hat 5°F, full speed

    1 pairing · 47°F 17,300 Btu/h · 95°F cooling 18,000 Btu/h · Cold output 42% · COP 1.88

  3. MPCE30B1MN10TA brand not stated 7,300 Btu/hat 5°F, full speed

    1 pairing · 47°F 16,600 Btu/h · 95°F cooling 18,000 Btu/h · Cold output 44% · COP 1.90

  4. MPCE30B2MN10TA brand not stated 7,600 Btu/hat 5°F, full speed

    1 pairing · 47°F 16,600 Btu/h · 95°F cooling 18,000 Btu/h · Cold output 46% · COP 1.94

  5. MPCE36B1MN10TA brand not stated 7,300 Btu/hat 5°F, full speed

    1 pairing · 47°F 16,600 Btu/h · 95°F cooling 18,000 Btu/h · Cold output 44% · COP 1.88

  6. MPCE36B2MN10TA brand not stated 7,600 Btu/hat 5°F, full speed

    1 pairing · 47°F 16,600 Btu/h · 95°F cooling 18,000 Btu/h · Cold output 46% · COP 1.94

  7. MPUE30B1MN10TA brand not stated 7,300 Btu/hat 5°F, full speed

    1 pairing · 47°F 16,500 Btu/h · 95°F cooling 18,000 Btu/h · Cold output 44% · COP 1.90

  8. MPUE30B2MN10TA brand not stated 7,600 Btu/hat 5°F, full speed

    1 pairing · 47°F 16,600 Btu/h · 95°F cooling 18,000 Btu/h · Cold output 46% · COP 1.94

  9. MPUE36B1MN10TA brand not stated 7,300 Btu/hat 5°F, full speed

    1 pairing · 47°F 16,500 Btu/h · 95°F cooling 18,000 Btu/h · Cold output 44% · COP 1.88

  10. MPUE36B2MN10TA brand not stated 7,600 Btu/hat 5°F, full speed

    1 pairing · 47°F 16,600 Btu/h · 95°F cooling 18,000 Btu/h · Cold output 46% · COP 1.94

  11. MVME24A1MN10OA+TXV (the pairing on screen) brand not stated 7,500 Btu/hat 5°F, full speed

    1 pairing · 47°F 17,200 Btu/h · 95°F cooling 18,000 Btu/h · Cold output 44% · COP 1.88

  12. MVME24A1MN10TA brand not stated 7,500 Btu/hat 5°F, full speed

    1 pairing · 47°F 17,200 Btu/h · 95°F cooling 18,000 Btu/h · Cold output 44% · COP 1.88

  13. MVME36B1MN10OA+TXV brand not stated 7,500 Btu/hat 5°F, full speed

    1 pairing · 47°F 18,000 Btu/h · 95°F cooling 18,000 Btu/h · Cold output 42% · COP 1.90

  14. MVME36B1MN10TA brand not stated 7,500 Btu/hat 5°F, full speed

    1 pairing · 47°F 18,000 Btu/h · 95°F cooling 18,000 Btu/h · Cold output 42% · COP 1.90

Indoor units in the air handler class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · one speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
MHVE18A1MN10TB — 7,200 16,500 18,000 44% 1.88 NC 1
MHVE24A1MN10TB — 7,200 17,300 18,000 42% 1.88 NC 1
MPCE30B1MN10TA — 7,300 16,600 18,000 44% 1.90 NC 1
MPCE30B2MN10TA — 7,600 16,600 18,000 46% 1.94 NC 1
MPCE36B1MN10TA — 7,300 16,600 18,000 44% 1.88 NC 1
MPCE36B2MN10TA — 7,600 16,600 18,000 46% 1.94 NC 1
MPUE30B1MN10TA — 7,300 16,500 18,000 44% 1.90 NC 1
MPUE30B2MN10TA — 7,600 16,600 18,000 46% 1.94 NC 1
MPUE36B1MN10TA — 7,300 16,500 18,000 44% 1.88 NC 1
MPUE36B2MN10TA — 7,600 16,600 18,000 46% 1.94 NC 1
MVME24A1MN10OA+TXV (the pairing on screen) — 7,500 17,200 18,000 44% 1.88 NC 1
MVME24A1MN10TA — 7,500 17,200 18,000 44% 1.88 NC 1
MVME36B1MN10OA+TXV — 7,500 18,000 18,000 42% 1.90 NC 1
MVME36B1MN10TA — 7,500 18,000 18,000 42% 1.90 NC 1

The share is heat output at 5°F divided by the 47°F rating.

Showing 14 of 14 indoor units

Sold as, and units with identical certified values

Brands listing this model number

Model number as listed

Variants of the same model number

2 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.

1 of 2 shown.

Other model numbers with identical certified values

2 units share this record. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.

1 of 2 shown.

Product history

  • MOVC-18HN10-M152L first appeared in the certified data between May 2025 and June 2025.

History and definitions

History

First certified record
Most recent certified record
Measurements reported
Jun 18, 2025
Status
In the certified data

Field definitions

COP
Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
HSPF2
Heating efficiency over a typical season. Higher uses less electricity.
SEER2
Cooling efficiency over a typical season. Higher uses less electricity.
EER2
Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
Cold output
Heat output at 5°F as a percentage of the 47°F rating.
% of rating at 17°F
Heat output at 17°F as a percentage of the 47°F rating.

NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read

Cite or print this page

Heat Pump List, “MOVC-18HN10-M152L — certified heat output”. Certified figures dated , checked daily.
https://heatpumplist.com/model/mova-18hn10-m152l