MOVB-24HDN10-M16G
Midea · central heat pump
All 359 certified Midea models
MOVB-24HDN10-M16G is in the certified data as of Sep 19, 2026.
- 24,000 Btu (2-ton)
- Central
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
24,0007.03NR
No 47°F rating for this pairing.
17,6005.16NR at 17°F
16,8004.92NR at 5°F
Btu/hkW, certified
1.80NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 24,000 Btu/h7.03 kW of heat at 47°F, 17,600 Btu/h5.16 kW at 17°F, and 16,800 Btu/h4.92 kW at 5°F, 70% of its 47°F rating. It delivers 23,600 Btu/h6.92 kW of cooling at 95°F. At 5°F that is 2,200 Btu/h0.64 kW short of the example heating load of 19,000 Btu/h5.57 kW; at 95°F it is 14,100 Btu/h4.13 kW above the example cooling load of 9,500 Btu/h2.78 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 2-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 800 sq ft where winters reach 5°F: heating runs from 19,000 Btu/h5.57 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 9,500 Btu/h2.78 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 215218936 · listed by Midea · certified Apr 22, 2026 · 9 pairings share these values
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 16,8004.92 kW | −12% | 1.80 | |
| 17°Ffull speed | 17,6005.16 kW | −8% | NR | |
| 47°Fnormal speed | 24,0007.03 kW | 0% | NR | |
| 95°Fcooling, full load | 23,6006.92 kW | — | NR |
EER2 10.6 in that test. SEER2 16.0 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 2.74kW
- Electrical input in the 95°F cooling test
- 2.23kW
- Seasonal average heating COP
- 2.49
These exclude backup resistance heat.
How it compares with other 24,000 Btu heat pumps
2-ton central models
- This pairing at 5°F
- 16,800 Btu/h4.92 kWNR
- This unit at 5°F median across its pairings
- 16,800 Btu/h4.92 kW
- Median of 2-ton central models at 5°F
- 19,000 Btu/h5.57 kW
- Models in this group
- 565
This unit is above 28% of them, at number 407 of 565 by heat at 5°F. The middle half of the group runs 16,000 to 21,600 Btu/h.
Among 24,000 Btu central models, each by its median certified pairing, highest first: 5°F output as a share of its 47°F rating, 407th of 565 (tied); HSPF2, 350th of 578 (tied). Models without that figure are left out.
Similar ratings at 47°F
These central models share the nominal cooling size. Comparisons use each model’s median certified figures across pairings.
- MDPH18024D: The same 24,000 Btu/h rating at 47°F; 29,000 Btu/h at 5°F (this model: 16,800).
- AC024BXUPCH: The same 24,000 Btu/h rating at 47°F; 26,000 Btu/h at 5°F (this model: 16,800).
- FRP18AZ24AJVC: The same 24,000 Btu/h rating at 47°F; 24,800 Btu/h at 5°F (this model: 16,800).
Closest models by heat at 5°F
- RD17AZ24AJ3NFriedrich, Rheem + 3 more · 16,900 Btu/h
- YH1824GHFD18R2Pioneer · 16,900 Btu/h
- MOVA-36HDN1-M16GMidea · 16,800 Btu/h
- YD524E2D11York · 16,800 Btu/h
- 27VNA024A*030*Carrier · 16,600 Btu/h
- B5H0V24*K*AAA*ACiQ, Airquest + 7 more · 16,400 Btu/h
Every 24,000 Btu (2-ton) unit, ranked by cooling efficiency, then heating efficiency
Floor area at the cold test point
The median certified output of 16,800 Btu/h at 5°F matches the size calculator’s heating estimate for these floor areas, rounded to about 10 sq ft. Each range divides that output by the climate band’s heating rates.
| Climate band | House condition | Btu/h per sq ft | Approximate sq ft |
|---|---|---|---|
| Mild | Drafty, little insulation | 24–42 | 400–700 |
| Mild | Typical | 16–26 | 650–1,050 |
| Mild | Tight, well insulated | 10–18 | 930–1,680 |
| Cold | Drafty, little insulation | 28–52 | 320–600 |
| Cold | Typical | 18–30 | 560–930 |
| Cold | Tight, well insulated | 12–22 | 760–1,400 |
| Very cold | Drafty, little insulation | 32–58 | 290–530 |
| Very cold | Typical | 22–38 | 440–760 |
| Very cold | Tight, well insulated | 16–28 | 600–1,050 |
This is an estimate, not a house-specific load calculation. Output stays at the 5°F test point for every band; it does not predict output at the band’s winter design temperature.
Certified values for MOVB-24HDN10-M16G
24 pairings · 24 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 24,000 Btu/h7.03 kWNR | 18,000–24,000 Btu/h5.28–7.03 kW |
| Heat output at 17°F full speed | 17,600 Btu/h5.16 kWNR | 14,800–20,200 Btu/h4.34–5.92 kW |
| Heat output at 5°F full speed | 16,800 Btu/h4.92 kWNR | 12,800–17,200 Btu/h3.75–5.04 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 70%NR | |
| COP at 5°F full speed | 1.80NR | 1.80–1.84 |
| HSPF2 Region IV | 8.5NR | 8.5–9.0 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 23,600 Btu/h6.92 kWNR | 18,000–24,000 Btu/h5.28–7.03 kW |
| EER2 at 95°F | 10.6NR | 10.5–11.7 |
| SEER2 cooling season | 16.0NR | 15.2–18.0 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-454B | |
| Compressor | Variable speed | |
| Indoor unit | MC**2430AN10TH | 15 indoor units |
| Furnace | MGV96U060B3C | 4 furnaces |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On some pairings |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | MOVB-24HDN10-M16G | |
Across 24 certified pairings with 15 indoor models: heat at 5°F 12,800 Btu/h with MHVE18A1MN10TB to 17,200 Btu/h with MVME24B2MN10TB; HSPF2 8.5 with MC**2430AN10TH to 9.0 with MHVE18A1MN10TB; SEER2 15.2 with MHVE24A1MN10TB to 18.0 with MVME24B2MN10TB. Endpoints name one indoor model where recorded; the furnace pairing can also change the figures.
Pairings, by indoor-unit class
15 indoor units · 24 certified pairings
One row per indoor unit certified with this outdoor unit.
Furnace paired · 3 indoor units
-
MC**2430AN10TH (the pairing on screen) brand not stated 16,800 Btu/h4.92 kWat 5°F, full speed
-
MC**2430BN10TH (the pairing on screen) brand not stated 16,800 Btu/h4.92 kWat 5°F, full speed
-
MC**3036BN10TH (the pairing on screen) brand not stated 16,800 Btu/h4.92 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| MC**2430AN10TH (the pairing on screen) | — | 16,8004.92 | 24,0007.03 | 23,6006.92 | 70% | 1.80 | Yes | 4 |
| MC**2430BN10TH (the pairing on screen) | — | 16,8004.92 | 24,0007.03 | 23,8006.98 | 70% | 1.80 | Yes | 4 |
| MC**3036BN10TH (the pairing on screen) | — | 16,8004.92 | 24,0007.03 | 23,8006.98 | 70% | 1.80 | Yes | 4 |
Air handler · 12 indoor units
-
MC**2430AN10TH+MEME05A3B (the pairing on screen) brand not stated 16,800 Btu/h4.92 kWat 5°F, full speed
-
MC**2430BN10TH+MEME05B4B (the pairing on screen) brand not stated 16,800 Btu/h4.92 kWat 5°F, full speed
-
MC**3036BN10TH+MEME05B4B (the pairing on screen) brand not stated 16,800 Btu/h4.92 kWat 5°F, full speed
-
MHVE18A1MN10TB (the pairing on screen) brand not stated 12,800 Btu/h3.75 kWat 5°F, full speed
-
MHVE24A1MN10TB (the pairing on screen) brand not stated 16,800 Btu/h4.92 kWat 5°F, full speed
-
MPCE18A1MN10TA (the pairing on screen) brand not stated 12,900 Btu/h3.78 kWat 5°F, full speed
-
MPCE24A1MN10TA (the pairing on screen) brand not stated 16,700 Btu/h4.89 kWat 5°F, full speed
-
MPUE18A1MN10TA (the pairing on screen) brand not stated 12,900 Btu/h3.78 kWat 5°F, full speed
-
MPUE24A1MN10TA (the pairing on screen) brand not stated 16,700 Btu/h4.89 kWat 5°F, full speed
-
MVME24B2MN10TB (the pairing on screen) brand not stated 17,200 Btu/h5.04 kWat 5°F, full speed
-
MVME24B2MN10TD (the pairing on screen) brand not stated 17,200 Btu/h5.04 kWat 5°F, full speed
-
MVMP24B2MN10TA (the pairing on screen) brand not stated 17,000 Btu/h4.98 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| MC**2430AN10TH+MEME05A3B (the pairing on screen) | — | 16,8004.92 | 24,0007.03 | 23,6006.92 | 70% | 1.80 | Yes | 1 |
| MC**2430BN10TH+MEME05B4B (the pairing on screen) | — | 16,8004.92 | 24,0007.03 | 24,0007.03 | 70% | 1.80 | Yes | 1 |
| MC**3036BN10TH+MEME05B4B (the pairing on screen) | — | 16,8004.92 | 24,0007.03 | 24,0007.03 | 70% | 1.80 | Yes | 1 |
| MHVE18A1MN10TB (the pairing on screen) | — | 12,8003.75 | 18,0005.28 | 18,0005.28 | 71% | 1.81 | Yes | 1 |
| MHVE24A1MN10TB (the pairing on screen) | — | 16,8004.92 | 23,8006.98 | 23,8006.98 | 71% | 1.80 | Yes | 1 |
| MPCE18A1MN10TA (the pairing on screen) | — | 12,9003.78 | 18,0005.28 | 18,0005.28 | 72% | 1.81 | Yes | 1 |
| MPCE24A1MN10TA (the pairing on screen) | — | 16,7004.89 | 23,6006.92 | 23,4006.86 | 71% | 1.81 | Yes | 1 |
| MPUE18A1MN10TA (the pairing on screen) | — | 12,9003.78 | 18,0005.28 | 18,0005.28 | 72% | 1.81 | Yes | 1 |
| MPUE24A1MN10TA (the pairing on screen) | — | 16,7004.89 | 23,6006.92 | 23,4006.86 | 71% | 1.81 | Yes | 1 |
| MVME24B2MN10TB (the pairing on screen) | — | 17,2005.04 | 24,0007.03 | 24,0007.03 | 72% | 1.84 | Yes | 1 |
| MVME24B2MN10TD (the pairing on screen) | — | 17,2005.04 | 24,0007.03 | 24,0007.03 | 72% | 1.84 | Yes | 1 |
| MVMP24B2MN10TA (the pairing on screen) | — | 17,0004.98 | 24,0007.03 | 24,0007.03 | 71% | 1.80 | Yes | 1 |
Sold as, and units with identical certified values
Brands listing this model number
Model number as listed
- MOVB-24HDN10-M16G 24 pairings
Variants of the same model number
4 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
3 of 4 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
History and definitions
Other XD16H-LGWP models by nominal cooling size: MOVB-36HDN10-M16G (24,000 Btu), MOVC-24HDN10-M16G (24,000 Btu), MOVB-60HDN10-M16G (42,000 Btu), MOVC-60HDN10-M16G (42,000 Btu).
History
- First certified record
- Most recent certified record
- Measurements reported
- Apr 22, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read