Heat Pump List

Tools

MOVB-24HDN10-M16G

Midea · central heat pump

All 359 certified Midea models

MOVB-24HDN10-M16G is in the certified data as of Sep 19, 2026.

24 certified pairings with 8 different figures. See all

Certified heating and cooling

Heating at 47°F

24,000

17,600 at 17°F

16,800 at 5°F

Btu/h, certified

1.80 COP at 5°F

Cooling at 95°F

23,600

Btu/h, certified

EER2 10.6 at 95°F

SEER2 16.0

Heating and cooling by outdoor temperature

Certified heating at 5, 17, and 47°F and cooling at 95°F for MOVB-24HDN10-M16G, by outdoor temperature Heating: 16,800 Btu/h at 5°F, 17,600 Btu/h at 17°F, 24,000 Btu/h at 47°F. Cooling: 23,600 Btu/h at 95°F. The bars start at zero. Median of 2-ton central models: 19,000 Btu/h at 5°F, 19,200 Btu/h at 17°F, 24,000 Btu/h at 47°F, 24,000 Btu/h at 95°F. 0 5,000 10,000 15,000 20,000 25,000 Btu/h 16,800 5°F 17,600 17°F 24,000 47°F 23,600 95°F Outdoor temperature (°F)
  • Heating output
  • Cooling output
  • Median of 2-ton central models
  • Example heating load
  • Example cooling load
  • Frosting range, 17 to 45°F

This pairing delivers 24,000 Btu/h of heat at 47°F, 17,600 Btu/h at 17°F, and 16,800 Btu/h at 5°F, 70% of its 47°F rating. It delivers 23,600 Btu/h of cooling at 95°F. At 5°F that is 2,200 Btu/h short of the example heating load of 19,000 Btu/h; at 95°F it is 14,100 Btu/h above the example cooling load of 9,500 Btu/h.

Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 2-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.

The dashed lines are example loads for a typical area of about 800 sq ft where winters reach 5°F: heating runs from 19,000 Btu/h at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 9,500 Btu/h at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.

Calculate heating and cooling for your house

AHRI certificate 215218936 · listed by Midea · certified Apr 22, 2026 · 9 pairings share these values

Certified output and power use

Certified output for the selected pairingThe four bars share one scale. The comparison is with the median of 2-ton central models. Heating tests run at 70°F indoors. The cooling test runs at 80°F indoors.
Outdoor temperature Certified outputBtu/h One scale vs class median COPat 5°F
5°Ffull speed 16,8004.92 kW −12% 1.80
17°Ffull speed 17,6005.16 kW −8% NR
47°Fnormal speed 24,0007.03 kW 0% NR
95°Fcooling, full load 23,6006.92 kW — NR

EER2 10.6 in that test. SEER2 16.0 over the modeled cooling season.

Power use at each temperature

Electrical input in the 5°F full-speed test
2.74kW
Electrical input in the 95°F cooling test
2.23kW
Seasonal average heating COP
2.49

These exclude backup resistance heat.

Updated Sep 19, 2026 · Methodology

How it compares with other 24,000 Btu heat pumps

2-ton central models

This pairing at 5°F
16,800 Btu/h
This unit at 5°F median across its pairings
16,800 Btu/h
Median of 2-ton central models at 5°F
19,000 Btu/h
Models in this group
565

This unit is above 28% of them, at number 407 of 565 by heat at 5°F. The middle half of the group runs 16,000 to 21,600 Btu/h.

This size class is defined by cooling capacity, so cooling is not compared here.

Among 24,000 Btu central models, each by its median certified pairing, highest first: 5°F output as a share of its 47°F rating, 407th of 565 (tied); HSPF2, 350th of 578 (tied). Models without that figure are left out.

Similar ratings at 47°F

These central models share the nominal cooling size. Comparisons use each model’s median certified figures across pairings.

  • MDPH18024D: The same 24,000 Btu/h rating at 47°F; 29,000 Btu/h at 5°F (this model: 16,800).
  • AC024BXUPCH: The same 24,000 Btu/h rating at 47°F; 26,000 Btu/h at 5°F (this model: 16,800).
  • FRP18AZ24AJVC: The same 24,000 Btu/h rating at 47°F; 24,800 Btu/h at 5°F (this model: 16,800).

Closest models by heat at 5°F

Every 24,000 Btu (2-ton) unit, ranked by cooling efficiency, then heating efficiency

Floor area at the cold test point

The median certified output of 16,800 Btu/h at 5°F matches the size calculator’s heating estimate for these floor areas, rounded to about 10 sq ft. Each range divides that output by the climate band’s heating rates.

Floor area by climate band and house condition
Climate bandHouse conditionBtu/h per sq ftApproximate sq ft
MildDrafty, little insulation24–42400–700
MildTypical16–26650–1,050
MildTight, well insulated10–18930–1,680
ColdDrafty, little insulation28–52320–600
ColdTypical18–30560–930
ColdTight, well insulated12–22760–1,400
Very coldDrafty, little insulation32–58290–530
Very coldTypical22–38440–760
Very coldTight, well insulated16–28600–1,050

This is an estimate, not a house-specific load calculation. Output stays at the 5°F test point for every band; it does not predict output at the band’s winter design temperature.

Certified values for MOVB-24HDN10-M16G

24 pairings · 24 AHRI certificates

This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.

Certified values for MOVB-24HDN10-M16G
This pairingAll pairings
Heating
Heat output at 47°F normal speed 24,000 Btu/h 18,000–24,000 Btu/h
Heat output at 17°F full speed 17,600 Btu/h 14,800–20,200 Btu/h
Heat output at 5°F full speed 16,800 Btu/h 12,800–17,200 Btu/h
Heat output below 5°F NR NR
Cold output 5°F output as a % of the 47°F rating 70%
COP at 5°F full speed 1.80 1.80–1.84
HSPF2 Region IV 8.5 8.5–9.0
Cooling
Cooling capacity at 95°F full-load test 23,600 Btu/h 18,000–24,000 Btu/h
EER2 at 95°F 10.6 10.5–11.7
SEER2 cooling season 16.0 15.2–18.0
Cooling at other temperatures NR NR
Equipment and listing
Refrigerant R-454B
Compressor Variable speed
Indoor unit MC**2430AN10TH 15 indoor units
FurnaceMGV96U060B3C 4 furnaces
Cold-climate designation EPA's designation, as published Yes On every pairing
ENERGY STAR Most Efficient EPA's designation, as published Yes On some pairings
Where it is sold US and Canada US and Canada
Model string as certified MOVB-24HDN10-M16G

Across 24 certified pairings with 15 indoor models: heat at 5°F 12,800 Btu/h with MHVE18A1MN10TB to 17,200 Btu/h with MVME24B2MN10TB; HSPF2 8.5 with MC**2430AN10TH to 9.0 with MHVE18A1MN10TB; SEER2 15.2 with MHVE24A1MN10TB to 18.0 with MVME24B2MN10TB. Endpoints name one indoor model where recorded; the furnace pairing can also change the figures.

Pairings, by indoor-unit class

15 indoor units · 24 certified pairings

One row per indoor unit certified with this outdoor unit.

Furnace paired · 3 indoor units

  1. MC**2430AN10TH (the pairing on screen) brand not stated 16,800 Btu/hat 5°F, full speed

    4 pairings, 4 with a furnace · 47°F 24,000 Btu/h · 95°F cooling 23,600 Btu/h · Cold output 70% · COP 1.80

  2. MC**2430BN10TH brand not stated 16,800 Btu/hat 5°F, full speed

    4 pairings, 4 with a furnace · 47°F 24,000 Btu/h · 95°F cooling 23,800 Btu/h · Cold output 70% · COP 1.80

  3. MC**3036BN10TH brand not stated 16,800 Btu/hat 5°F, full speed

    4 pairings, 4 with a furnace · 47°F 24,000 Btu/h · 95°F cooling 23,800 Btu/h · Cold output 70% · COP 1.80

Indoor units in the furnace paired class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · normal speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
MC**2430AN10TH (the pairing on screen) — 16,800 24,000 23,600 70% 1.80 Yes 4
MC**2430BN10TH — 16,800 24,000 23,800 70% 1.80 Yes 4
MC**3036BN10TH — 16,800 24,000 23,800 70% 1.80 Yes 4

Air handler · 12 indoor units

  1. MC**2430AN10TH+MEME05A3B brand not stated 16,800 Btu/hat 5°F, full speed

    1 pairing · 47°F 24,000 Btu/h · 95°F cooling 23,600 Btu/h · Cold output 70% · COP 1.80

  2. MC**2430BN10TH+MEME05B4B brand not stated 16,800 Btu/hat 5°F, full speed

    1 pairing · 47°F 24,000 Btu/h · 95°F cooling 24,000 Btu/h · Cold output 70% · COP 1.80

  3. MC**3036BN10TH+MEME05B4B brand not stated 16,800 Btu/hat 5°F, full speed

    1 pairing · 47°F 24,000 Btu/h · 95°F cooling 24,000 Btu/h · Cold output 70% · COP 1.80

  4. MHVE18A1MN10TB brand not stated 12,800 Btu/hat 5°F, full speed

    1 pairing · 47°F 18,000 Btu/h · 95°F cooling 18,000 Btu/h · Cold output 71% · COP 1.81

  5. MHVE24A1MN10TB brand not stated 16,800 Btu/hat 5°F, full speed

    1 pairing · 47°F 23,800 Btu/h · 95°F cooling 23,800 Btu/h · Cold output 71% · COP 1.80

  6. MPCE18A1MN10TA brand not stated 12,900 Btu/hat 5°F, full speed

    1 pairing · 47°F 18,000 Btu/h · 95°F cooling 18,000 Btu/h · Cold output 72% · COP 1.81

  7. MPCE24A1MN10TA brand not stated 16,700 Btu/hat 5°F, full speed

    1 pairing · 47°F 23,600 Btu/h · 95°F cooling 23,400 Btu/h · Cold output 71% · COP 1.81

  8. MPUE18A1MN10TA brand not stated 12,900 Btu/hat 5°F, full speed

    1 pairing · 47°F 18,000 Btu/h · 95°F cooling 18,000 Btu/h · Cold output 72% · COP 1.81

  9. MPUE24A1MN10TA brand not stated 16,700 Btu/hat 5°F, full speed

    1 pairing · 47°F 23,600 Btu/h · 95°F cooling 23,400 Btu/h · Cold output 71% · COP 1.81

  10. MVME24B2MN10TB brand not stated 17,200 Btu/hat 5°F, full speed

    1 pairing · 47°F 24,000 Btu/h · 95°F cooling 24,000 Btu/h · Cold output 72% · COP 1.84

  11. MVME24B2MN10TD brand not stated 17,200 Btu/hat 5°F, full speed

    1 pairing · 47°F 24,000 Btu/h · 95°F cooling 24,000 Btu/h · Cold output 72% · COP 1.84

  12. MVMP24B2MN10TA brand not stated 17,000 Btu/hat 5°F, full speed

    1 pairing · 47°F 24,000 Btu/h · 95°F cooling 24,000 Btu/h · Cold output 71% · COP 1.80

Indoor units in the air handler class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · normal speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
MC**2430AN10TH+MEME05A3B — 16,800 24,000 23,600 70% 1.80 Yes 1
MC**2430BN10TH+MEME05B4B — 16,800 24,000 24,000 70% 1.80 Yes 1
MC**3036BN10TH+MEME05B4B — 16,800 24,000 24,000 70% 1.80 Yes 1
MHVE18A1MN10TB — 12,800 18,000 18,000 71% 1.81 Yes 1
MHVE24A1MN10TB — 16,800 23,800 23,800 71% 1.80 Yes 1
MPCE18A1MN10TA — 12,900 18,000 18,000 72% 1.81 Yes 1
MPCE24A1MN10TA — 16,700 23,600 23,400 71% 1.81 Yes 1
MPUE18A1MN10TA — 12,900 18,000 18,000 72% 1.81 Yes 1
MPUE24A1MN10TA — 16,700 23,600 23,400 71% 1.81 Yes 1
MVME24B2MN10TB — 17,200 24,000 24,000 72% 1.84 Yes 1
MVME24B2MN10TD — 17,200 24,000 24,000 72% 1.84 Yes 1
MVMP24B2MN10TA — 17,000 24,000 24,000 71% 1.80 Yes 1

The share is heat output at 5°F divided by the 47°F rating.

Showing 15 of 15 indoor units

Sold as, and units with identical certified values

Brands listing this model number

Model number as listed

Variants of the same model number

4 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.

3 of 4 shown.

History and definitions

Other XD16H-LGWP models by nominal cooling size: MOVB-36HDN10-M16G (24,000 Btu), MOVC-24HDN10-M16G (24,000 Btu), MOVB-60HDN10-M16G (42,000 Btu), MOVC-60HDN10-M16G (42,000 Btu).

History

First certified record
Most recent certified record
Measurements reported
Apr 22, 2026
Status
In the certified data

Field definitions

COP
Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
HSPF2
Heating efficiency over a typical season. Higher uses less electricity.
SEER2
Cooling efficiency over a typical season. Higher uses less electricity.
EER2
Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
Cold output
Heat output at 5°F as a percentage of the 47°F rating.
% of rating at 17°F
Heat output at 17°F as a percentage of the 47°F rating.

NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read

Cite or print this page

Heat Pump List, “MOVB-24HDN10-M16G — certified heat output”. Certified figures dated , checked daily.