MPP15AY36AJ2N
Mainline · central heat pump
MPP15AY36AJ2N is in the certified data as of Sep 19, 2026.
- 36,000 Btu (3-ton)
- Central
- Two-stage
- United States
Certified heating and cooling
Heating at 47°F
34,20010.02NR
No 47°F rating for this pairing.
33,2009.73NR at 17°F
18,5005.42NR at 5°F
Btu/hkW, certified
2.00NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 34,200 Btu/h10.02 kW of heat at 47°F, 33,200 Btu/h9.73 kW at 17°F, and 18,500 Btu/h5.42 kW at 5°F, 54% of its 47°F rating. It delivers 34,200 Btu/h10.02 kW of cooling at 95°F. At 5°F that is 8,000 Btu/h2.34 kW short of the example heating load of 26,500 Btu/h7.77 kW; at 95°F it is 21,200 Btu/h6.21 kW above the example cooling load of 13,000 Btu/h3.81 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at high stage; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 3-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 1,100 sq ft where winters reach 5°F: heating runs from 26,500 Btu/h7.77 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 13,000 Btu/h3.81 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 216687697 · listed by MAINLINE · certified Oct 2, 2025 · 1 pairing carries these values
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 18,5005.42 kW | −30% | 2.00 | |
| 17°Ffull speed | 33,2009.73 kW | +27% | NR | |
| 47°Fhigh stage | 34,20010.02 kW | −3% | NR | |
| 95°Fcooling, full load | 34,20010.02 kW | — | NR |
EER2 11.7 in that test. SEER2 15.2 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 2.71kW
- Electrical input in the 95°F cooling test
- 2.92kW
- Seasonal average heating COP
- 2.29
These exclude backup resistance heat.
How it compares with other 36,000 Btu heat pumps
3-ton central models
- This pairing at 5°F
- 18,500 Btu/h5.42 kWNR
- This unit at 5°F median across its pairings
- 18,500 Btu/h5.42 kW
- Median of 3-ton central models at 5°F
- 26,400 Btu/h7.74 kW
- Models in this group
- 451
This unit is above 23% of them, at number 348 of 451 by heat at 5°F. The middle half of the group runs 18,650 to 32,000 Btu/h.
Closest models by heat at 5°F
- FOP1536TJAYNAFujitsu · 18,500 Btu/h
- FRP15AY36AJ2NFriedrich · 18,500 Btu/h
- FWP15AY36AJ2NFriedrich · 18,500 Btu/h
- 4SHP22LX136P-**AAirEase and Armstrong Air · 18,300 Btu/h
- NS22H36MA4-**AGE · 18,200 Btu/h
- ML16KP2-036-230ALennox · 18,000 Btu/h
Every 36,000 Btu (3-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for MPP15AY36AJ2N
1 pairing · 1 AHRI certificate
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F high stage | 34,200 Btu/h10.02 kWNR | 34,200 Btu/h10.02 kW |
| Heat output at 17°F full speed | 33,200 Btu/h9.73 kWNR | 33,200 Btu/h9.73 kW |
| Heat output at 5°F full speed | 18,500 Btu/h5.42 kWNR | 18,500 Btu/h5.42 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 54%NR | |
| COP at 5°F full speed | 2.00NR | 2.00 |
| HSPF2 Region IV | 7.8NR | 7.8 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 34,200 Btu/h10.02 kWNR | 34,200 Btu/h10.02 kW |
| EER2 at 95°F | 11.7NR | 11.7 |
| SEER2 cooling season | 15.2NR | 15.2 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-454B | |
| Compressor | Two-stage | |
| Indoor unit | TCFY3621STANM | 1 indoor unit |
| Furnace | MP951W1005A21UH | 1 furnace |
| Cold-climate designation EPA's designation, as published | NC | NC |
| ENERGY STAR Most Efficient EPA's designation, as published | No | On no pairings |
| Where it is sold | United States | United States |
| Model string as certified | MPP15AY36AJ2N | |
Pairings, by indoor-unit class
1 indoor unit · 1 certified pairing
One row per indoor unit certified with this outdoor unit.
Furnace paired · 1 indoor unit
-
TCFY3621STANM (the pairing on screen) brand not stated 18,500 Btu/h5.42 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · high stage | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| TCFY3621STANM (the pairing on screen) | — | 18,5005.42 | 34,20010.02 | 34,20010.02 | 54% | 2.00 | NC | 1 |
Sold as, and units with identical certified values
Variants of the same model number
3 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
2 of 3 shown.
Other model numbers with identical certified values
3 units share this record. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
2 of 3 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Oct 2, 2025
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read