MPP15AZ18AJ2N

MPP15AZ18AJ2N is in the certified data.

Its certified full-speed heating output at 5°F is 9,200–9,500 Btu/h, 54–56% of its 47°F rating, depending on the pairing.

Mainline · central heat pump

All 82 certified Mainline models

MPP15AZ18AJ2N is in the certified data as of Sep 19, 2026.

7 certified pairings with 5 different figures. See all

Certified heating and cooling

Heating at 47°F

17,100

12,000 at 17°F

9,300 at 5°F

Btu/h, certified

2.10 COP at 5°F

Cooling at 95°F

17,100

Btu/h, certified

EER2 11.7 at 95°F

SEER2 15.2

Heating and cooling by outdoor temperature

Certified heating at 5, 17, and 47°F and cooling at 95°F for MPP15AZ18AJ2N, by outdoor temperature Heating: 9,300 Btu/h at 5°F, 12,000 Btu/h at 17°F, 17,100 Btu/h at 47°F. Cooling: 17,100 Btu/h at 95°F. The bars start at zero. Median of 1.5-ton central models: 11,200 Btu/h at 5°F, 12,600 Btu/h at 17°F, 18,000 Btu/h at 47°F, 18,000 Btu/h at 95°F. 0 5,000 10,000 15,000 20,000 Btu/h 9,300 5°F 12,000 17°F 17,100 47°F 17,100 95°F Outdoor temperature (°F)
  • Heating output
  • Cooling output
  • Median of 1.5-ton central models
  • Example heating load
  • Example cooling load
  • Frosting range, 17 to 45°F

This pairing delivers 17,100 Btu/h of heat at 47°F, 12,000 Btu/h at 17°F, and 9,300 Btu/h at 5°F, 54% of its 47°F rating. It delivers 17,100 Btu/h of cooling at 95°F. At 5°F that is 1,700 Btu/h short of the example heating load of 11,000 Btu/h; at 95°F it is 11,600 Btu/h above the example cooling load of 5,500 Btu/h.

Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at high stage; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 1.5-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.

The dashed lines are example loads for a typical area of about 450 sq ft where winters reach 5°F: heating runs from 11,000 Btu/h at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 5,500 Btu/h at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.

Calculate heating and cooling for your house

AHRI certificate 212507914 · listed by MAINLINE · certified Jul 7, 2026 · 2 pairings share these values

Rebates where you live

Meets the recorded equipment thresholds of 27 programs in 16 states, provinces, or territories:Colorado (1), Idaho (1), Kansas (1), Maryland (3), Michigan (2), Minnesota (3), Mississippi (1), Nevada (1), New Jersey (4), North Carolina (1), Oregon (2), Pennsylvania (3), South Carolina (1), Texas (3), Utah (1), Newfoundland and Labrador (1).

All 27 programs by state and province

Colorado

Idaho

Kansas

Maryland

Michigan

Minnesota

Mississippi

Nevada

New Jersey

North Carolina

Oregon

Pennsylvania

South Carolina

Texas

Utah

Newfoundland and Labrador

Threshold comparisons use the unit’s median certified figures across its pairings, not the pairing selected above. Meeting these thresholds means the equipment may qualify; it does not guarantee approval. Service-area, installation, and product-list requirements also apply.

All rebate programs and their published thresholds

Certified output and power use

Certified output for the selected pairingThe four bars share one scale. The comparison is with the median of 1.5-ton central models. Heating tests run at 70°F indoors. The cooling test runs at 80°F indoors.
Outdoor temperature Certified outputBtu/h One scale vs class median COPat 5°F
5°Fone compressor speed 9,3002.73 kW −17% 2.10
17°Fone compressor speed 12,0003.52 kW −5% NR
47°Fone compressor speed 17,1005.01 kW −5% NR
95°Fcooling, full load 17,1005.01 kW — NR

EER2 11.7 in that test. SEER2 15.2 over the modeled cooling season.

Power use at each temperature

Electrical input in the 5°F full-speed test
1.30kW
Electrical input in the 95°F cooling test
1.46kW
Seasonal average heating COP
2.29

These exclude backup resistance heat.

Updated Sep 19, 2026 · Methodology

How it compares with other 18,000 Btu heat pumps

1.5-ton central models

This pairing at 5°F
9,300 Btu/h
This unit at 5°F median across its pairings
9,300 Btu/h
Median of 1.5-ton central models at 5°F
11,200 Btu/h
Models in this group
243

This unit is above 35% of them, at number 159 of 243 by heat at 5°F. The middle half of the group runs 8,600 to 18,000 Btu/h.

This size class is defined by cooling capacity, so cooling is not compared here.

Among 18,000 Btu central models, each by its median certified pairing, highest first: 5°F output as a share of its 47°F rating, 151st of 243 (tied); HSPF2, 191st of 254 (tied). Models without that figure are left out.

Similar ratings at 47°F

These central models share the nominal cooling size. Comparisons use each model’s median certified figures across pairings.

  • FOP1518TJAYNA: The same 17,100 Btu/h rating at 47°F; 8,200 Btu/h at 5°F (this model: 9,300).
  • FXU12HP230V1R32AO: 17,000 Btu/h at 47°F (this model: 17,100); 17,000 Btu/h at 5°F (this model: 9,300).
  • GZV6SA181MA: 17,200 Btu/h at 47°F (this model: 17,100); 13,000 Btu/h at 5°F (this model: 9,300).

Closest models by heat at 5°F

Every 18,000 Btu (1.5-ton) unit, ranked by cooling efficiency, then heating efficiency

Floor area at the cold test point

The median certified output of 9,300 Btu/h at 5°F matches the size calculator’s heating estimate for these floor areas, rounded to about 10 sq ft. Each range divides that output by the climate band’s heating rates.

Floor area by climate band and house condition
Climate bandHouse conditionBtu/h per sq ftApproximate sq ft
MildDrafty, little insulation24–42220–390
MildTypical16–26360–580
MildTight, well insulated10–18520–930
ColdDrafty, little insulation28–52180–330
ColdTypical18–30310–520
ColdTight, well insulated12–22420–780
Very coldDrafty, little insulation32–58160–290
Very coldTypical22–38240–420
Very coldTight, well insulated16–28330–580

This is an estimate, not a house-specific load calculation. Output stays at the 5°F test point for every band; it does not predict output at the band’s winter design temperature.

Certified values for MPP15AZ18AJ2N

7 pairings · 7 AHRI certificates

This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.

Certified values for MPP15AZ18AJ2N
This pairingAll pairings
Heating
Heat output at 47°F high stage 17,100 Btu/h 17,100 Btu/h
Heat output at 17°F full speed 12,000 Btu/h 11,600–12,100 Btu/h
Heat output at 5°F full speed 9,300 Btu/h 9,200–9,500 Btu/h
Heat output below 5°F NR NR
Cold output 5°F output as a % of the 47°F rating 54%
COP at 5°F full speed 2.10 2.10
HSPF2 Region IV 7.8 7.8–8.1
Cooling
Cooling capacity at 95°F full-load test 17,100 Btu/h 17,100 Btu/h
EER2 at 95°F 11.7 11.7
SEER2 cooling season 15.2 15.2
Cooling at other temperatures NR NR
Equipment and listing
Refrigerant R-410A
Compressor Two-stage
Indoor unit TCFZ2417STANM 2 indoor units
FurnaceMP951W0403A17M4S 6 furnaces
Cold-climate designation EPA's designation, as published NC On some pairings
ENERGY STAR Most Efficient EPA's designation, as published No On no pairings
Where it is sold US and Canada US and Canada
Model string as certified MPP15AZ18AJ2N

Across 7 certified pairings with 2 indoor models: heat at 5°F 9,200 Btu/h with MPH2CZ2417STANN to 9,500 Btu/h with TCFZ2417STANM; HSPF2 7.8 with MPH2CZ2417STANN to 8.1 with TCFZ2417STANM; SEER2 15.2 throughout. Endpoints name one indoor model where recorded; the furnace pairing can also change the figures.

Pairings, by indoor-unit class

2 indoor units · 7 certified pairings

One row per indoor unit certified with this outdoor unit.

Furnace paired · 1 indoor unit

  1. TCFZ2417STANM (the pairing on screen) brand not stated 9,350 Btu/hat 5°F, full speed

    6 pairings, 6 with a furnace · 47°F 17,100 Btu/h · 95°F cooling 17,100 Btu/h · Cold output 55% · COP 2.10

Indoor units in the furnace paired class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · high stage At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
TCFZ2417STANM (the pairing on screen) — 9,350 17,100 17,100 55% 2.10 Yes 6

Air handler · 1 indoor unit

  1. MPH2CZ2417STANN brand not stated 9,200 Btu/hat 5°F, full speed

    1 pairing · 47°F 17,100 Btu/h · 95°F cooling 17,100 Btu/h · Cold output 54% · COP 2.10

Indoor units in the air handler class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · high stage At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
MPH2CZ2417STANN — 9,200 17,100 17,100 54% 2.10 NC 1

The share is heat output at 5°F divided by the 47°F rating.

Showing 2 of 2 indoor units

Sold as, and units with identical certified values

Brands listing this model number

Model number as listed

History and definitions

Other Performance models by nominal cooling size: MPP15AZ24AJ2N (24,000 Btu), MPP15AZ36AJ2N (36,000 Btu), MPP15AZ60AJ2N (54,000 Btu).

History

First certified record
Most recent certified record
Measurements reported
Jul 7, 2026
Status
In the certified data

Field definitions

COP
Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
HSPF2
Heating efficiency over a typical season. Higher uses less electricity.
SEER2
Cooling efficiency over a typical season. Higher uses less electricity.
EER2
Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
Cold output
Heat output at 5°F as a percentage of the 47°F rating.
% of rating at 17°F
Heat output at 17°F as a percentage of the 47°F rating.

NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read