MSH183G20MCAA
MSH183G20MCAA is in the certified data.
Its certified full-speed heating output at 5°F is 11,700 Btu/h3.43 kW, 62% of its 47°F rating (tests at different compressor speeds) in its certified pairing.
Goodman · mini-split heat pump
All 59 certified Goodman models
MSH183G20MCAA is in the certified data as of Sep 19, 2026.
- 18,000 Btu (1.5-ton)
- Mini-split
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
18,8005.51NR
No 47°F rating for this pairing.
11,4003.34NR at 17°F
11,7003.43NR at 5°F
Btu/hkW, certified
2.06NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 18,800 Btu/h5.51 kW of heat at 47°F, 11,400 Btu/h3.34 kW at 17°F, and 11,700 Btu/h3.43 kW at 5°F, 62% of its 47°F rating. It delivers 18,000 Btu/h5.28 kW of cooling at 95°F. At 5°F that is 2,300 Btu/h0.67 kW short of the example heating load of 14,000 Btu/h4.10 kW; at 95°F it is 11,000 Btu/h3.22 kW above the example cooling load of 7,000 Btu/h2.05 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 1.5-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 600 sq ft where winters reach 5°F: heating runs from 14,000 Btu/h4.10 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 7,000 Btu/h2.05 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 214442642 · listed by Goodman · certified Jun 13, 2026 · 1 pairing carries these values
Rebates where you live
Meets the recorded equipment thresholds of 34 programs in 23 states, provinces, or territories:Alabama (1), Arizona (1), California (2), Delaware (1), Idaho (2), Illinois (1), Kentucky (1), Maryland (3), Michigan (2), Minnesota (1), Mississippi (2), New Jersey (3), New York (4), Oregon (2), Pennsylvania (1), Tennessee (1), Texas (1), Utah (1), Vermont (3), Washington (1), Wisconsin (1), British Columbia (3), Newfoundland and Labrador (1).
All 34 programs by state and province
Alabama
Arizona
California
Delaware
Idaho
Illinois
Kentucky
Maryland
- BGE Smart Energy Savers Heating and Cooling
- Delmarva Power Maryland HVAC Efficiency Program
- Pepco Maryland HVAC Efficiency Program
Michigan
Minnesota
Mississippi
- EnergyRight Home Energy Rebates · TVA EnergyRight · EPB
- Entergy Mississippi Residential Heating and Cooling
New Jersey
- Atlantic City Electric Building Decarbonization
- PSE&G Residential Building Decarbonization
- Rockland Electric Clean Heat
New York
- EmPower+
- NYS Clean Heat: Central Hudson, NYSEG, RG&E, and O&R · Orange & Rockland
- NYS Clean Heat: Con Edison
- NYS Clean Heat: National Grid
Oregon
- Energy Trust of Oregon Heat Pump Incentives · Portland General Electric (PGE) · Pacific Power
- Idaho Power Heating and Cooling Efficiency Program
Pennsylvania
Tennessee
Texas
Utah
Vermont
- Burlington Electric Heat Pump Rebates · Burlington Electric Department
- Efficiency Vermont Heat Pump Discounts
- Green Mountain Power Income-Eligible Heat Pump Rebate
Washington
Wisconsin
British Columbia
- CleanBC Energy Savings Program · BC Hydro · FortisBC · municipal utilities
- Home Renovation Rebate: Heat Pump Replacing Electric Heat · BC Hydro · FortisBC · Grand Forks · Penticton · Summerland · Nelson Hydro
- Home Renovation Rebate: Northern Fuel Switch · BC Hydro · Pacific Northern Gas · FortisBC (gas)
Newfoundland and Labrador
Threshold comparisons use the unit’s median certified figures across its pairings, not the pairing selected above. Meeting these thresholds means the equipment may qualify; it does not guarantee approval. Service-area, installation, and product-list requirements also apply.
A utility program is for that utility's customers.
Choose location
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 11,7003.43 kW | −18% | 2.06 | |
| 17°Ffull speed | 11,4003.34 kW | −23% | NR | |
| 47°Fnormal speed | 18,8005.51 kW | +4% | NR | |
| 95°Fcooling, full load | 18,0005.28 kW | — | NR |
EER2 11.0 in that test. SEER2 19.5 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 1.66kW
- Electrical input in the 95°F cooling test
- 1.64kW
- Seasonal average heating COP
- 2.55
These exclude backup resistance heat.
How it compares with other 18,000 Btu heat pumps
1.5-ton mini-split models
- This pairing at 5°F
- 11,700 Btu/h3.43 kWNR
- This unit at 5°F median across its pairings
- 11,700 Btu/h3.43 kW
- Median of 1.5-ton mini-split models at 5°F
- 14,200 Btu/h4.16 kW
- Models in this group
- 1,110
This unit is above 6% of them, at number 1,044 of 1,110 by heat at 5°F. The middle half of the group runs 13,000 to 18,000 Btu/h.
Among 18,000 Btu mini-split models, each by its median certified pairing, highest first: 5°F output as a share of its 47°F rating, 1,032nd of 1,110 (tied); HSPF2, 1,030th of 1,114 (tied). Models without that figure are left out.
Similar ratings at 47°F
These mini-split models share the nominal cooling size. Comparisons use each model’s median certified figures across pairings.
- SUZ-KA18NAHZ: The same 18,800 Btu/h rating at 47°F; 9,000 Btu/h at 5°F (this model: 11,700).
- MUZ-FS18NA: 19,000 Btu/h at 47°F (this model: 18,800); 22,400 Btu/h at 5°F (this model: 11,700).
- H18FMHD3XPC: 19,000 Btu/h at 47°F (this model: 18,800); 19,300 Btu/h at 5°F (this model: 11,700).
Closest models by heat at 5°F
- 38MHRCQ18AA3Bryant, Carrier + 3 more · 11,700 Btu/h
- DIY-18-HP-C-230CMRCOOL · 11,700 Btu/h
- MOX430-18HFN1-MT2Q1WAlsetria, Eco Air + 1 more · 11,700 Btu/h
- PIAW1821080ABPremium Levella · 11,600 Btu/h
- RX18BXVJUDaikin · 11,600 Btu/h
- 37MHRAQ18AA3Bryant, Carrier + 3 more · 11,500 Btu/h
Every 18,000 Btu (1.5-ton) unit, ranked by cooling efficiency, then heating efficiency
Floor area at the cold test point
The median certified output of 11,700 Btu/h at 5°F matches the size calculator’s heating estimate for these floor areas, rounded to about 10 sq ft. Each range divides that output by the climate band’s heating rates.
| Climate band | House condition | Btu/h per sq ft | Approximate sq ft |
|---|---|---|---|
| Mild | Drafty, little insulation | 24–42 | 280–490 |
| Mild | Typical | 16–26 | 450–730 |
| Mild | Tight, well insulated | 10–18 | 650–1,170 |
| Cold | Drafty, little insulation | 28–52 | 230–420 |
| Cold | Typical | 18–30 | 390–650 |
| Cold | Tight, well insulated | 12–22 | 530–980 |
| Very cold | Drafty, little insulation | 32–58 | 200–370 |
| Very cold | Typical | 22–38 | 310–530 |
| Very cold | Tight, well insulated | 16–28 | 420–730 |
This is an estimate, not a house-specific load calculation. Output stays at the 5°F test point for every band; it does not predict output at the band’s winter design temperature.
Certified values for MSH183G20MCAA
1 pairing · 1 AHRI certificate
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 18,800 Btu/h5.51 kWNR | 18,800 Btu/h5.51 kW |
| Heat output at 17°F full speed | 11,400 Btu/h3.34 kWNR | 11,400 Btu/h3.34 kW |
| Heat output at 5°F full speed | 11,700 Btu/h3.43 kWNR | 11,700 Btu/h3.43 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 62%NR | |
| COP at 5°F full speed | 2.06NR | 2.06 |
| HSPF2 Region IV | 8.7NR | 8.7 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 18,000 Btu/h5.28 kWNR | 18,000 Btu/h5.28 kW |
| EER2 at 95°F | 11.0NR | 11.0 |
| SEER2 cooling season | 19.5NR | 19.5 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-410A | |
| Compressor | Variable speed | |
| Indoor unit | MSH183G20AXAA | 1 indoor unit |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | NC | NC |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On every pairing |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | MSH183G20MCAA | |
Pairings, by indoor-unit class
1 indoor unit · 1 certified pairing
One row per indoor unit certified with this outdoor unit.
Ductless indoor · 1 indoor unit
-
MSH183G20AXAA (the pairing on screen) GOODMAN 11,700 Btu/h3.43 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| MSH183G20AXAA (the pairing on screen) | GOODMAN | 11,7003.43 | 18,8005.51 | 18,0005.28 | 62% | 2.06 | NC | 1 |
Sold as, and units with identical certified values
Variants of the same model number
21 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
- 18H421ZOMISea Breeze
- 18MSZ-M-AMulti MFG
- AAG21-18H1BApooDr
- AO21-18N1-M1AI Air Conditioning
- BMY1820CBlueridge
- CARAT18CD(O)-HPComfortStar
- CGS18CD(O)ComfortStar
- CH-NY18MIA-230VOC&H · Cooper&Hunter
- CHI18CD(O)ComfortStar
- DLCERBH18AAKAirquest · Arcoaire · Comfortmaker · Day & Night · Heil · Keeprite · Kenmore · LPS Legacy · Midea · Smart Comfort · Tempstar · Viessmann
- GA-18HP230V/OGenie Aire
- LBH18DTOLBG Products
- LEA18SZ15SK-ONovair
- MASAG18-21HS2GBMidea
- ODUMOX330-18HFN1-MS0WKepler
- RO-SZ18-AB-QMitsutomo
- SHC18VC2AGSlimAir
- WSB-18HFMOWells
- ZMSB-18HV-US-OZero
- ZMSB-18HVD-USZero
20 of 21 shown.
Other model numbers with identical certified values
18 units share this record. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
- 18H421ZOMIidentical certified values
- 18MSZ-M-Aidentical certified values
- AAG21-18H1Bidentical certified values
- AO21-18N1-M1identical certified values
- BMY1820Cidentical certified values
- CARAT18CD(O)-HPidentical certified values
- CGS18CD(O)identical certified values
- CHI18CD(O)identical certified values
- GA-18HP230V/Oidentical certified values
- LBH18DTOidentical certified values
- LEA18SZ15SK-Oidentical certified values
- ODUMOX330-18HFN1-MS0Widentical certified values
- RO-SZ18-AB-Qidentical certified values
- SHC18VC2AGidentical certified values
- WSB-18HFMOidentical certified values
- ZMSB-18HV-US-Oidentical certified values
- ZMSB-18HVD-USidentical certified values
17 of 18 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
Product history
- MSH183G20MCAA first appeared in the certified data between March 2025 and May 2025.
History and definitions
Other MSH Series models by nominal cooling size: MSH093E23MCAA (9,000 Btu), MSH093G22MCAA (9,000 Btu), MSH093G26MCAA (9,000 Btu), MSH123E23MCAA (12,000 Btu), MSH123G22MCAA (12,000 Btu), MSH123G26MCAA (12,000 Btu), MSH123G32MCAA (12,000 Btu), MSH183E23MCAA (18,000 Btu); more models from this brand.
History
- First certified record
- Most recent certified record
- Measurements reported
- Jun 13, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read