MSH183G26MCAA
MSH183G26MCAA is in the certified data.
Its certified full-speed heating output at 5°F is 24,000 Btu/h7.03 kW, 120% of its 47°F rating (tests at different compressor speeds) in its certified pairing.
Goodman · mini-split heat pump
MSH183G26MCAA is in the certified data as of Sep 19, 2026. MSH183G26MCAA changed its certified HSPF2 on AHRI certificate 214438121 from 15.5 to 11.0 in the certified data between August 2025 and September 2026.
- 18,000 Btu (1.5-ton)
- Mini-split
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
20,0005.86NR
No 47°F rating for this pairing.
20,2005.92NR at 17°F
24,0007.03NR at 5°F
Btu/hkW, certified
2.89NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 20,000 Btu/h5.86 kW of heat at 47°F, 20,200 Btu/h5.92 kW at 17°F, and 24,000 Btu/h7.03 kW at 5°F, 120% of its 47°F rating. It delivers 18,000 Btu/h5.28 kW of cooling at 95°F. At 5°F that is 10,000 Btu/h2.93 kW above the example heating load of 14,000 Btu/h4.10 kW; at 95°F it is 11,000 Btu/h3.22 kW above the example cooling load of 7,000 Btu/h2.05 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 1.5-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 600 sq ft where winters reach 5°F: heating runs from 14,000 Btu/h4.10 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 7,000 Btu/h2.05 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 214438121 · listed by Goodman · certified Jun 13, 2026 · 1 pairing carries these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 24,0007.03 kW | +69% | 2.89 | |
| 17°Ffull speed | 20,2005.92 kW | +36% | NR | |
| 47°Fnormal speed | 20,0005.86 kW | +11% | NR | |
| 95°Fcooling, full load | 18,0005.28 kW | — | NR |
EER2 15.3 in that test. SEER2 26.3 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 2.43kW
- Electrical input in the 95°F cooling test
- 1.18kW
- Seasonal average heating COP
- 3.22
These exclude backup resistance heat.
How it compares with other 18,000 Btu heat pumps
1.5-ton mini-split models
- This pairing at 5°F
- 24,000 Btu/h7.03 kWNR
- This unit at 5°F median across its pairings
- 24,000 Btu/h7.03 kW
- Median of 1.5-ton mini-split models at 5°F
- 14,200 Btu/h4.16 kW
- Models in this group
- 1,110
This unit is above 99% of them, at number 10 of 1,110 by heat at 5°F. The middle half of the group runs 13,000 to 18,000 Btu/h.
Closest models by heat at 5°F
- MUZ-FX24NLHZMitsubishi Electric · 26,600 Btu/h
- AOUH18KZAH1Fujitsu · 24,800 Btu/h
- DLCPRBH18AAKAirquest, Arcoaire + 10 more · 24,000 Btu/h
- QO1-M3Z27-NC*NAQuilt · 24,000 Btu/h
- MUZ-FX18NLHZMitsubishi Electric · 23,600 Btu/h
- AOUH18KUAH1Fujitsu · 23,200 Btu/h
Every 18,000 Btu (1.5-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for MSH183G26MCAA
1 pairing · 1 AHRI certificate
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 20,000 Btu/h5.86 kWNR | 20,000 Btu/h5.86 kW |
| Heat output at 17°F full speed | 20,200 Btu/h5.92 kWNR | 20,200 Btu/h5.92 kW |
| Heat output at 5°F full speed | 24,000 Btu/h7.03 kWNR | 24,000 Btu/h7.03 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 120%NR | |
| COP at 5°F full speed | 2.89NR | 2.89 |
| HSPF2 Region IV | 11.0NR | 11.0 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 18,000 Btu/h5.28 kWNR | 18,000 Btu/h5.28 kW |
| EER2 at 95°F | 15.3NR | 15.3 |
| SEER2 cooling season | 26.3NR | 26.3 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-410A | |
| Compressor | Variable speed | |
| Indoor unit | MSH183G26AXAA | 1 indoor unit |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On every pairing |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | MSH183G26MCAA | |
Pairings, by indoor-unit class
1 indoor unit · 1 certified pairing
One row per indoor unit certified with this outdoor unit.
Ductless indoor · 1 indoor unit
-
MSH183G26AXAA (the pairing on screen) GOODMAN 24,000 Btu/h7.03 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| MSH183G26AXAA (the pairing on screen) | GOODMAN | 24,0007.03 | 20,0005.86 | 18,0005.28 | 120% | 2.89 | Yes | 1 |
Sold as, and units with identical certified values
Variants of the same model number
5 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
- 38MPRBQ18AA3Bryant · Carrier · Midea · Payne · WeatherMaker
- DMA18HOS42230E4MoovAir
- DMB18HOS42230E8BMoovAir
- MOD30-18HFN1-MZ20WMDV
4 of 5 shown.
Other model numbers with identical certified values
4 units share this record. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
- DMA18HOS42230E4identical certified values
- DMB18HOS42230E8Bidentical certified values
- MOD30-18HFN1-MZ20Widentical certified values
3 of 4 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
Product history
- MSH183G26MCAA changed its certified HSPF2 on AHRI certificate 214438121 from 15.5 to 11.0 in the certified data between August 2025 and September 2026.
- MSH183G26MCAA was in the certified data by September 2024.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Jun 13, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read