Heat Pump List

Tools

MSH183G26MCAA

MSH183G26MCAA is in the certified data.

Its certified full-speed heating output at 5°F is 24,000 Btu/h, 120% of its 47°F rating (tests at different compressor speeds) in its certified pairing.

Goodman · mini-split heat pump

MSH183G26MCAA is in the certified data as of Sep 19, 2026. MSH183G26MCAA changed its certified HSPF2 on AHRI certificate 214438121 from 15.5 to 11.0 in the certified data between August 2025 and September 2026.

Certified heating and cooling

Heating at 47°F

20,000

20,200 at 17°F

24,000 at 5°F

Btu/h, certified

2.89 COP at 5°F

Cooling at 95°F

18,000

Btu/h, certified

EER2 15.3 at 95°F

SEER2 26.3

Heating and cooling by outdoor temperature

Certified heating at 5, 17, and 47°F and cooling at 95°F for MSH183G26MCAA, by outdoor temperature Heating: 24,000 Btu/h at 5°F, 20,200 Btu/h at 17°F, 20,000 Btu/h at 47°F. Cooling: 18,000 Btu/h at 95°F. The bars start at zero. Median of 1.5-ton mini-split models: 14,200 Btu/h at 5°F, 14,800 Btu/h at 17°F, 18,000 Btu/h at 47°F, 18,000 Btu/h at 95°F. 0 5,000 10,000 15,000 20,000 25,000 Btu/h 24,000 5°F 20,200 17°F 20,000 47°F 18,000 95°F Outdoor temperature (°F)
  • Heating output
  • Cooling output
  • Median of 1.5-ton mini-split models
  • Example heating load
  • Example cooling load
  • Frosting range, 17 to 45°F

This pairing delivers 20,000 Btu/h of heat at 47°F, 20,200 Btu/h at 17°F, and 24,000 Btu/h at 5°F, 120% of its 47°F rating. It delivers 18,000 Btu/h of cooling at 95°F. At 5°F that is 10,000 Btu/h above the example heating load of 14,000 Btu/h; at 95°F it is 11,000 Btu/h above the example cooling load of 7,000 Btu/h.

Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 1.5-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.

The dashed lines are example loads for a typical area of about 600 sq ft where winters reach 5°F: heating runs from 14,000 Btu/h at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 7,000 Btu/h at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.

Calculate heating and cooling for your house

AHRI certificate 214438121 · listed by Goodman · certified Jun 13, 2026 · 1 pairing carries these values

All rebate programs and their published thresholds

Certified output and power use

Certified output for the selected pairingThe four bars share one scale. The comparison is with the median of 1.5-ton mini-split models. Heating tests run at 70°F indoors. The cooling test runs at 80°F indoors.
Outdoor temperature Certified outputBtu/h One scale vs class median COPat 5°F
5°Ffull speed 24,0007.03 kW +69% 2.89
17°Ffull speed 20,2005.92 kW +36% NR
47°Fnormal speed 20,0005.86 kW +11% NR
95°Fcooling, full load 18,0005.28 kW — NR

EER2 15.3 in that test. SEER2 26.3 over the modeled cooling season.

Power use at each temperature

Electrical input in the 5°F full-speed test
2.43kW
Electrical input in the 95°F cooling test
1.18kW
Seasonal average heating COP
3.22

These exclude backup resistance heat.

Updated Sep 19, 2026 · Methodology

How it compares with other 18,000 Btu heat pumps

1.5-ton mini-split models

This pairing at 5°F
24,000 Btu/h
This unit at 5°F median across its pairings
24,000 Btu/h
Median of 1.5-ton mini-split models at 5°F
14,200 Btu/h
Models in this group
1,110

This unit is above 99% of them, at number 10 of 1,110 by heat at 5°F. The middle half of the group runs 13,000 to 18,000 Btu/h.

This size class is defined by cooling capacity, so cooling is not compared here.

Closest models by heat at 5°F

Every 18,000 Btu (1.5-ton) unit, ranked by cooling efficiency, then heating efficiency

Certified values for MSH183G26MCAA

1 pairing · 1 AHRI certificate

This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.

Certified values for MSH183G26MCAA
This pairingAll pairings
Heating
Heat output at 47°F normal speed 20,000 Btu/h 20,000 Btu/h
Heat output at 17°F full speed 20,200 Btu/h 20,200 Btu/h
Heat output at 5°F full speed 24,000 Btu/h 24,000 Btu/h
Heat output below 5°F NR NR
Cold output 5°F output as a % of the 47°F rating 120%
COP at 5°F full speed 2.89 2.89
HSPF2 Region IV 11.0 11.0
Cooling
Cooling capacity at 95°F full-load test 18,000 Btu/h 18,000 Btu/h
EER2 at 95°F 15.3 15.3
SEER2 cooling season 26.3 26.3
Cooling at other temperatures NR NR
Equipment and listing
Refrigerant R-410A
Compressor Variable speed
Indoor unit MSH183G26AXAA 1 indoor unit
FurnaceNo furnace None
Cold-climate designation EPA's designation, as published Yes On every pairing
ENERGY STAR Most Efficient EPA's designation, as published Yes On every pairing
Where it is sold US and Canada US and Canada
Model string as certified MSH183G26MCAA

Pairings, by indoor-unit class

1 indoor unit · 1 certified pairing

One row per indoor unit certified with this outdoor unit.

Ductless indoor · 1 indoor unit

  1. MSH183G26AXAA (the pairing on screen) GOODMAN 24,000 Btu/hat 5°F, full speed

    1 pairing · 47°F 20,000 Btu/h · 95°F cooling 18,000 Btu/h · Cold output 120% · COP 2.89

Indoor units in the ductless indoor class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · normal speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
MSH183G26AXAA (the pairing on screen) GOODMAN 24,000 20,000 18,000 120% 2.89 Yes 1

The share is heat output at 5°F divided by the 47°F rating.

Showing 1 of 1 indoor unit

Sold as, and units with identical certified values

Brands listing this model number

Model number as listed

Variants of the same model number

5 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.

4 of 5 shown.

Other model numbers with identical certified values

4 units share this record. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.

3 of 4 shown.

Product history

  • MSH183G26MCAA changed its certified HSPF2 on AHRI certificate 214438121 from 15.5 to 11.0 in the certified data between August 2025 and September 2026.
  • MSH183G26MCAA was in the certified data by September 2024.

History and definitions

History

First certified record
Most recent certified record
Measurements reported
Jun 13, 2026
Status
In the certified data

Field definitions

COP
Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
HSPF2
Heating efficiency over a typical season. Higher uses less electricity.
SEER2
Cooling efficiency over a typical season. Higher uses less electricity.
EER2
Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
Cold output
Heat output at 5°F as a percentage of the 47°F rating.
% of rating at 17°F
Heat output at 17°F as a percentage of the 47°F rating.

NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read

Cite or print this page

Heat Pump List, “MSH183G26MCAA — certified heat output”. Certified figures dated , checked daily.