MULTI18HP230V1EO
MULTI18HP230V1EO is in the certified data.
Its certified full-speed heating output at 5°F is 13,600 Btu/h3.99 kW, 76% of its 47°F rating (tests at different compressor speeds) in its certified pairing.
Gree · mini-split heat pump
MULTI18HP230V1EO is in the certified data as of Sep 19, 2026. MULTI18HP230V1EO changed its certified heat output at 17°F on AHRI certificate 210278973 from 14,700 Btu/h to 15,000 Btu/h in the certified data between March 2025 and May 2025.
- 18,000 Btu (1.5-ton)
- Mini-split
- Variable speed
- Canada
Certified heating and cooling
Heating at 47°F
18,0005.28NR
No 47°F rating for this pairing.
15,0004.40NR at 17°F
13,6003.99NR at 5°F
Btu/hkW, certified
2.22NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 18,000 Btu/h5.28 kW of heat at 47°F, 15,000 Btu/h4.40 kW at 17°F, and 13,600 Btu/h3.99 kW at 5°F, 76% of its 47°F rating. It delivers 17,000 Btu/h4.98 kW of cooling at 95°F. At 5°F that is 400 Btu/h0.12 kW short of the example heating load of 14,000 Btu/h4.10 kW; at 95°F it is 10,000 Btu/h2.93 kW above the example cooling load of 7,000 Btu/h2.05 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 1.5-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 600 sq ft where winters reach 5°F: heating runs from 14,000 Btu/h4.10 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 7,000 Btu/h2.05 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 210278973 · listed by GREE · certified Jun 13, 2026 · 1 pairing carries these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 13,6003.99 kW | −4% | 2.22 | |
| 17°Ffull speed | 15,0004.40 kW | +1% | NR | |
| 47°Fnormal speed | 18,0005.28 kW | 0% | NR | |
| 95°Fcooling, full load | 17,0004.98 kW | — | NR |
EER2 12.0 in that test. SEER2 21.0 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 1.80kW
- Electrical input in the 95°F cooling test
- 1.42kW
- Seasonal average heating COP
- 2.93
These exclude backup resistance heat.
How it compares with other 18,000 Btu heat pumps
1.5-ton mini-split models
- This pairing at 5°F
- 13,600 Btu/h3.99 kWNR
- This unit at 5°F median across its pairings
- 13,600 Btu/h3.99 kW
- Median of 1.5-ton mini-split models at 5°F
- 14,200 Btu/h4.16 kW
- Models in this group
- 1,110
This unit is above 35% of them, at number 717 of 1,110 by heat at 5°F. The middle half of the group runs 13,000 to 18,000 Btu/h.
Closest models by heat at 5°F
- 048-C-TP-18K2V-23S-OUTDella · 13,600 Btu/h
- GMS18 PROGarvee · 13,600 Btu/h
- M4THM1918A12NAmeristar and RunTru · 13,600 Btu/h
- TM18HPOTosot · 13,600 Btu/h
- WLWHD(18)ND3MOGree · 13,600 Btu/h
- 048-MS-18K2VR-22S-M-OUTDella · 13,500 Btu/h
Every 18,000 Btu (1.5-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for MULTI18HP230V1EO
1 pairing · 1 AHRI certificate
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 18,000 Btu/h5.28 kWNR | 18,000 Btu/h5.28 kW |
| Heat output at 17°F full speed | 15,000 Btu/h4.40 kWNR | 15,000 Btu/h4.40 kW |
| Heat output at 5°F full speed | 13,600 Btu/h3.99 kWNR | 13,600 Btu/h3.99 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 76%NR | |
| COP at 5°F full speed | 2.22NR | 2.22 |
| HSPF2 Region IV | 10.0NR | 10.0 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 17,000 Btu/h4.98 kWNR | 17,000 Btu/h4.98 kW |
| EER2 at 95°F | 12.0NR | 12.0 |
| SEER2 cooling season | 21.0NR | 21.0 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-410A | |
| Compressor | Variable speed | |
| Indoor unit | None listed | None |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On every pairing |
| Where it is sold | Canada | Canada |
| Model string as certified | MULTI18HP230V1EO | |
Pairings, by indoor-unit class
1 certified pairing
One row per indoor unit certified with this outdoor unit.
Ductless indoor
-
None listed (the pairing on screen) GREE 13,600 Btu/h3.99 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| None listed (the pairing on screen) | GREE | 13,6003.99 | 18,0005.28 | 17,0004.98 | 76% | 2.22 | Yes | 1 |
Sold as, and units with identical certified values
Variants of the same model number
13 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
- 4TXM2118A12N0American Standard · Trane
- A-VFH18DC-1Comfort-Aire
- AWHD(18)ND3MOAC Pro
- BBM18HX4OWabban
- BMKH18MCBlueridge
- GFMCX18-H2Comformatic
- GXH18(5.3)FMK4DH-1AireForce · Airtemp · Gibson
- MBRS18HPJ1OEBoreal
- MPD18KCH21SB-OACD
- MZ-M18/OTosot
- MZUHW18KCH21S2-OWillis
- TM18HMOTosot
12 of 13 shown.
Other model numbers with identical certified values
10 units share this record. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
- A-VFH18DC-1identical certified values
- BBM18HX4Oidentical certified values
- BMKH18MCidentical certified values
- GFMCX18-H2identical certified values
- MBRS18HPJ1OEidentical certified values
- MPD18KCH21SB-Oidentical certified values
- MZ-M18/Oidentical certified values
- MZUHW18KCH21S2-Oidentical certified values
- TM18HMOidentical certified values
9 of 10 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
Product history
- MULTI18HP230V1EO changed its certified heat output at 17°F on AHRI certificate 210278973 from 14,700 Btu/h to 15,000 Btu/h in the certified data between March 2025 and May 2025.
- MULTI18HP230V1EO was in the certified data by September 2024.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Jun 13, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read