MULTI30HP230V1EO
MULTI30HP230V1EO is in the certified data.
Its certified full-speed heating output at 5°F is 22,800 Btu/h6.68 kW, 76% of its 47°F rating (tests at different compressor speeds) in its certified pairing.
Gree · mini-split heat pump
MULTI30HP230V1EO is in the certified data as of Sep 19, 2026.
- 30,000 Btu (2.5-ton)
- Mini-split
- Variable speed
- Canada
Certified heating and cooling
Heating at 47°F
30,0008.79NR
No 47°F rating for this pairing.
27,2007.97NR at 17°F
22,8006.68NR at 5°F
Btu/hkW, certified
1.84NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 30,000 Btu/h8.79 kW of heat at 47°F, 27,200 Btu/h7.97 kW at 17°F, and 22,800 Btu/h6.68 kW at 5°F, 76% of its 47°F rating. It delivers 28,400 Btu/h8.32 kW of cooling at 95°F. At 5°F that is 2,200 Btu/h0.64 kW short of the example heating load of 25,000 Btu/h7.33 kW; at 95°F it is 15,900 Btu/h4.66 kW above the example cooling load of 12,500 Btu/h3.66 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 2.5-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 1,050 sq ft where winters reach 5°F: heating runs from 25,000 Btu/h7.33 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 12,500 Btu/h3.66 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 210278977 · listed by GREE · certified Jun 13, 2026 · 1 pairing carries these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 22,8006.68 kW | −9% | 1.84 | |
| 17°Ffull speed | 27,2007.97 kW | +6% | NR | |
| 47°Fnormal speed | 30,0008.79 kW | 0% | NR | |
| 95°Fcooling, full load | 28,4008.32 kW | — | NR |
EER2 12.5 in that test. SEER2 21.0 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 3.63kW
- Electrical input in the 95°F cooling test
- 2.27kW
- Seasonal average heating COP
- 2.93
These exclude backup resistance heat.
How it compares with other 30,000 Btu heat pumps
2.5-ton mini-split models
- This pairing at 5°F
- 22,800 Btu/h6.68 kWNR
- This unit at 5°F median across its pairings
- 22,800 Btu/h6.68 kW
- Median of 2.5-ton mini-split models at 5°F
- 25,000 Btu/h7.33 kW
- Models in this group
- 405
This unit is above 33% of them, at number 270 of 405 by heat at 5°F. The middle half of the group runs 20,000 to 27,000 Btu/h.
Closest models by heat at 5°F
- TUM-36HA2/I2I21-21ESTCL · 23,000 Btu/h
- TWH30AT19D6DOTosot · 23,000 Btu/h
- M4THM1930A14NAmeristar and RunTru · 22,800 Btu/h
- ASH3036TRDFGE · 21,800 Btu/h
- AO-30U3R25EHisense · 21,400 Btu/h
- GWH30ATEXH-D6DNA1G/OGree · 21,000 Btu/h
Every 30,000 Btu (2.5-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for MULTI30HP230V1EO
1 pairing · 1 AHRI certificate
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 30,000 Btu/h8.79 kWNR | 30,000 Btu/h8.79 kW |
| Heat output at 17°F full speed | 27,200 Btu/h7.97 kWNR | 27,200 Btu/h7.97 kW |
| Heat output at 5°F full speed | 22,800 Btu/h6.68 kWNR | 22,800 Btu/h6.68 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 76%NR | |
| COP at 5°F full speed | 1.84NR | 1.84 |
| HSPF2 Region IV | 10.0NR | 10.0 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 28,400 Btu/h8.32 kWNR | 28,400 Btu/h8.32 kW |
| EER2 at 95°F | 12.5NR | 12.5 |
| SEER2 cooling season | 21.0NR | 21.0 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-410A | |
| Compressor | Variable speed | |
| Indoor unit | None listed | None |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | NC | NC |
| ENERGY STAR Most Efficient EPA's designation, as published | No | On no pairings |
| Where it is sold | Canada | Canada |
| Model string as certified | MULTI30HP230V1EO | |
Pairings, by indoor-unit class
1 certified pairing
One row per indoor unit certified with this outdoor unit.
Ductless indoor
-
None listed (the pairing on screen) GREE 22,800 Btu/h6.68 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| None listed (the pairing on screen) | GREE | 22,8006.68 | 30,0008.79 | 28,4008.32 | 76% | 1.84 | NC | 1 |
Sold as, and units with identical certified values
Variants of the same model number
12 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
- 4TXM2130A14N0American Standard · Trane
- AWHD(30)ND3MOAC Pro
- BBM30HX4OWabban
- BMKH30MCBlueridge
- GXH30(8.8)FMK4DH-1AireForce · Airtemp · Gibson
- MBRS30HPJ1OEBoreal
- MPD30KCH21SB-OACD
- MZ-M30/OTosot
- MZUHW30KCH21S2-OWillis
- SC-30Z-HH-M4B1HVAC
- TM30HMOTosot
11 of 12 shown.
Other model numbers with identical certified values
10 units share this record. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
- AWHD(30)ND3MOidentical certified values
- BBM30HX4Oidentical certified values
- BMKH30MCidentical certified values
- MBRS30HPJ1OEidentical certified values
- MPD30KCH21SB-Oidentical certified values
- MZ-M30/Oidentical certified values
- MZUHW30KCH21S2-Oidentical certified values
- SC-30Z-HH-M4Bidentical certified values
- TM30HMOidentical certified values
9 of 10 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Jun 13, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read