MUZ-FH12NAH
MUZ-FH12NAH is in the certified data.
Its certified ratings are 10.4 HSPF2 and 26.3 SEER2.
Mitsubishi Electric · mini-split heat pump
MUZ-FH12NAH is in the certified data as of Sep 19, 2026.
- 12,000 Btu (1-ton)
- Mini-split
- Variable speed
- United States
Certified heating and cooling
Heating at 47°F
13,6003.99NR
No 47°F rating for this pairing.
8,1002.37NR at 17°F
——NRNR at 5°F
Btu/hkW, certified
—NRNR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 13,600 Btu/h3.99 kW of heat at 47°F and 8,100 Btu/h2.37 kW at 17°F. It delivers 12,000 Btu/h3.52 kW of cooling at 95°F. At 95°F that is 7,000 Btu/h2.05 kW above the example cooling load of 5,000 Btu/h1.47 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 1-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 400 sq ft where winters reach 5°F: heating runs from 9,000 Btu/h2.64 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 5,000 Btu/h1.47 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 201754299 · listed by Mitsubishi Electric · certified Dec 2, 2025 · 1 pairing carries these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | NR— kW | NR | NR | |
| 17°Ffull speed | 8,1002.37 kW | −17% | NR | |
| 47°Fnormal speed | 13,6003.99 kW | +13% | NR | |
| 95°Fcooling, full load | 12,0003.52 kW | — | NR |
EER2 13.8 in that test. SEER2 26.3 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- NRkW
- Electrical input in the 95°F cooling test
- 0.87kW
- Seasonal average heating COP
- 3.05
These exclude backup resistance heat.
How it compares with other 12,000 Btu heat pumps
1-ton mini-split models
- This pairing at 5°F
- — Btu/h— kWNRNR
- This unit at 5°F median across its pairings
- NR
- Median of 1-ton mini-split models at 5°F
- 9,200 Btu/h2.70 kW
- Models in this group
- 888
Every 12,000 Btu (1-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for MUZ-FH12NAH
1 pairing · 1 AHRI certificate
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 13,600 Btu/h3.99 kWNR | 13,600 Btu/h3.99 kW |
| Heat output at 17°F full speed | 8,100 Btu/h2.37 kWNR | 8,100 Btu/h2.37 kW |
| Heat output at 5°F full speed | — Btu/h— kWNRNR | NR |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | —%NRNR | NR |
| COP at 5°F full speed | —NRNR | — |
| HSPF2 Region IV | 10.4NR | 10.4 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 12,000 Btu/h3.52 kWNR | 12,000 Btu/h3.52 kW |
| EER2 at 95°F | 13.8NR | 13.8 |
| SEER2 cooling season | 26.3NR | 26.3 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-410A | |
| Compressor | Variable speed | |
| Indoor unit | MSZ-FH12NA** | 1 indoor unit |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | NC | NC |
| ENERGY STAR Most Efficient EPA's designation, as published | No | On no pairings |
| Where it is sold | United States | United States |
| Model string as certified | MUZ-FH12NAH | |
Pairings, by indoor-unit class
1 indoor unit · 1 certified pairing
One row per indoor unit certified with this outdoor unit.
Ductless indoor · 1 indoor unit
-
MSZ-FH12NA** (the pairing on screen) Mitsubishi Electric NRat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| MSZ-FH12NA** (the pairing on screen) | Mitsubishi Electric | NR | 13,6003.99 | 12,0003.52 | NR | — | NC | 1 |
Sold as, and units with identical certified values
Brands listing this model number
Model number as listed
- MUZ-FH12NAH 1 pairing
New York program projects, 2017–2019
The MUZ-FH12NAH is the outdoor unit in 61 projects of a New York State heat pump program, approved between Nov 17, 2017 and Dec 13, 2019.
| Projects | Median | Middle half | |
|---|---|---|---|
| Whole-project cost | 61 | $5,000 | $4,401–$5,619 |
| Cost after reported incentive | 61 | $4,500 | $3,901–$5,119 |
Each cost covers the whole project, installation included. A project can include several indoor units, or more than one outdoor unit of this model.
The median is the middle project's cost. The middle half runs from the 25th to the 75th percentile.
Cost after reported incentive is the project cost minus the incentive the program reported. It is a comparison figure, not a homeowner's bill: the incentive could have gone to the installer or to the property owner.
Dollars are as recorded at approval, 2017–2019, and are not adjusted for inflation. The projects name this outdoor unit. Their indoor units may differ from the pairings certified above.
Project records as of Oct 17, 2026.
What affects the price
We don't have current prices or quotes. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Dec 2, 2025
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read