N5HP5042A1
N5HP5042A1 is in the certified data.
Its certified full-speed heating output at 5°F is 19,100–19,900 Btu/h5.60–5.83 kW, 50–52% of its 47°F rating, depending on the pairing.
American Standard and Trane · central heat pump
N5HP5042A1 is in the certified data as of Sep 19, 2026.
- 42,000 Btu (3.5-ton)
- Central
- Single stage
- United States
Certified heating and cooling
Heating at 47°F
38,00011.14NR
No 47°F rating for this pairing.
25,8007.56NR at 17°F
19,4005.69NR at 5°F
Btu/hkW, certified
2.18NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 38,000 Btu/h11.14 kW of heat at 47°F, 25,800 Btu/h7.56 kW at 17°F, and 19,400 Btu/h5.69 kW at 5°F, 51% of its 47°F rating. It delivers 39,000 Btu/h11.43 kW of cooling at 95°F. At 5°F that is 13,600 Btu/h3.99 kW short of the example heating load of 33,000 Btu/h9.67 kW; at 95°F it is 22,000 Btu/h6.45 kW above the example cooling load of 17,000 Btu/h4.98 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at one speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 3.5-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 1,400 sq ft where winters reach 5°F: heating runs from 33,000 Btu/h9.67 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 17,000 Btu/h4.98 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 218469721 · listed by Trane · certified Jun 29, 2026 · 4 pairings share these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Fone compressor speed | 19,4005.69 kW | −41% | 2.18 | |
| 17°Fone compressor speed | 25,8007.56 kW | −17% | NR | |
| 47°Fone compressor speed | 38,00011.14 kW | −14% | NR | |
| 95°Fcooling, full load | 39,00011.43 kW | — | NR |
EER2 12.0 in that test. SEER2 15.5 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 2.61kW
- Electrical input in the 95°F cooling test
- 3.25kW
- Seasonal average heating COP
- 2.37
These exclude backup resistance heat.
How it compares with other 42,000 Btu heat pumps
3.5-ton central models
- This pairing at 5°F
- 19,400 Btu/h5.69 kWNR
- This unit at 5°F median across its pairings
- 19,400 Btu/h5.69 kW
- Median of 3.5-ton central models at 5°F
- 33,000 Btu/h9.67 kW
- Models in this group
- 222
This unit is above 9% of them, at number 203 of 222 by heat at 5°F. The middle half of the group runs 20,000 to 40,000 Btu/h.
Closest models by heat at 5°F
- GH5SAN542**AA*Bryant and Carrier · 19,800 Btu/h
- WLP15AY42AJ2NWhirlpool · 19,700 Btu/h
- DRHP14B42AJ2ANDuraSTAR · 19,400 Btu/h
- 5TWR5042A1Trane · 19,300 Btu/h
- 5TWX5042A1Trane · 19,300 Btu/h
- A5HP5042A1Ameristar and RunTru · 19,300 Btu/h
Every 42,000 Btu (3.5-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for N5HP5042A1
144 pairings · 144 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F one speed | 38,000 Btu/h11.14 kWNR | 37,600–39,000 Btu/h11.02–11.43 kW |
| Heat output at 17°F full speed | 25,800 Btu/h7.56 kWNR | 25,200–26,200 Btu/h7.39–7.68 kW |
| Heat output at 5°F full speed | 19,400 Btu/h5.69 kWNR | 19,100–19,900 Btu/h5.60–5.83 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 51%NR | |
| COP at 5°F full speed | 2.18NR | 2.11–2.28 |
| HSPF2 Region IV | 8.1NR | 7.8–8.1 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 39,000 Btu/h11.43 kWNR | 38,000–41,000 Btu/h11.14–12.02 kW |
| EER2 at 95°F | 12.0NR | 11.7–12.0 |
| SEER2 cooling season | 15.5NR | 15.2–16.0 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-454B | |
| Compressor | Single stage | |
| Indoor unit | 5PX*C007AS3+TSTAT | 33 indoor units |
| Furnace | A952V100CU5SB | 19 furnaces |
| Cold-climate designation EPA's designation, as published | NC | NC |
| ENERGY STAR Most Efficient EPA's designation, as published | No | On no pairings |
| Where it is sold | United States | United States |
| Model string as certified | N5HP5042A1 | |
Pairings, by indoor-unit class
33 indoor units · 144 certified pairings
One row per indoor unit certified with this outdoor unit.
Furnace paired · 8 indoor units
-
5PX*C009AS3+TSTAT (the pairing on screen) brand not stated 19,400 Btu/h5.69 kWat 5°F, full speed
-
5PX*C007AS3+TSTAT (the pairing on screen) brand not stated 19,450 Btu/h5.70 kWat 5°F, full speed
-
5TXCC007AS3+TSTAT (the pairing on screen) brand not stated 19,450 Btu/h5.70 kWat 5°F, full speed
-
5PX*B006AS3+TSTAT (the pairing on screen) brand not stated 19,500 Btu/h5.71 kWat 5°F, full speed
-
5TXCB006AS3+TSTAT (the pairing on screen) brand not stated 19,500 Btu/h5.71 kWat 5°F, full speed
-
5PX*CD09AS3+TSTAT (the pairing on screen) brand not stated 19,550 Btu/h5.73 kWat 5°F, full speed
-
5PX*D008AS3+TSTAT (the pairing on screen) brand not stated 19,400 Btu/h5.69 kWat 5°F, full speed
-
5PX*DD10AS3+TSTAT (the pairing on screen) brand not stated 19,300 Btu/h5.66 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · one speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| 5PX*C009AS3+TSTAT (the pairing on screen) | — | 19,4005.69 | 38,00011.14 | 40,00011.72 | 51% | 2.21 | NC | 14 |
| 5PX*C007AS3+TSTAT (the pairing on screen) | — | 19,4505.70 | 38,50011.28 | 39,50011.58 | 51% | 2.17 | NC | 12 |
| 5TXCC007AS3+TSTAT (the pairing on screen) | — | 19,4505.70 | 38,50011.28 | 39,50011.58 | 51% | 2.17 | NC | 12 |
| 5PX*B006AS3+TSTAT (the pairing on screen) | — | 19,5005.71 | 38,00011.14 | 38,50011.28 | 51% | 2.16 | NC | 10 |
| 5TXCB006AS3+TSTAT (the pairing on screen) | — | 19,5005.71 | 38,00011.14 | 38,50011.28 | 51% | 2.17 | NC | 10 |
| 5PX*CD09AS3+TSTAT (the pairing on screen) | — | 19,5505.73 | 38,00011.14 | 40,00011.72 | 51% | 2.15 | NC | 8 |
| 5PX*D008AS3+TSTAT (the pairing on screen) | — | 19,4005.69 | 38,50011.28 | 40,00011.72 | 51% | 2.18 | NC | 6 |
| 5PX*DD10AS3+TSTAT (the pairing on screen) | — | 19,3005.66 | 38,00011.14 | 39,50011.58 | 51% | 2.20 | NC | 6 |
Air handler · 2 indoor units
-
5PX*D010AS3+TSTAT (the pairing on screen) brand not stated 19,350 Btu/h5.67 kWat 5°F, full speed
-
5TXCD010AS3+TSTAT (the pairing on screen) brand not stated 19,350 Btu/h5.67 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · one speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| 5PX*D010AS3+TSTAT (the pairing on screen) | — | 19,3505.67 | 38,25011.21 | 40,50011.87 | 51% | 2.23 | NC | 8 |
| 5TXCD010AS3+TSTAT (the pairing on screen) | — | 19,3505.67 | 38,25011.21 | 40,50011.87 | 51% | 2.23 | NC | 8 |
Sold as, and units with identical certified values
Brands listing this model number
Other brands that list these model numbers
Model number as listed
- N5HP5042A1 144 pairings
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Jun 29, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read