NS17H18SA4-**A
NS17H18SA4-**A is in the certified data.
Its certified full-speed heating output at 5°F is 7,500–9,700 Btu/h2.20–2.84 kW, 44–54% of its 47°F rating, depending on the pairing.
GE · central heat pump
NS17H18SA4-**A is in the certified data as of Sep 27, 2026.
- 18,000 Btu (1.5-ton)
- Central
- Single stage
- US and Canada
Certified heating and cooling
Heating at 47°F
17,4005.10NR
No 47°F rating for this pairing.
10,8003.17NR at 17°F
8,1002.37NR at 5°F
Btu/hkW, certified
1.94NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 17,400 Btu/h5.10 kW of heat at 47°F, 10,800 Btu/h3.17 kW at 17°F, and 8,100 Btu/h2.37 kW at 5°F, 47% of its 47°F rating. It delivers 18,000 Btu/h5.28 kW of cooling at 95°F. At 5°F that is 2,900 Btu/h0.85 kW short of the example heating load of 11,000 Btu/h3.22 kW; at 95°F it is 12,500 Btu/h3.66 kW above the example cooling load of 5,500 Btu/h1.61 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at one speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 1.5-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 450 sq ft where winters reach 5°F: heating runs from 11,000 Btu/h3.22 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 5,500 Btu/h1.61 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 210261923 · listed by GE · certified Oct 27, 2025 · 4 pairings share these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Fone compressor speed | 8,1002.37 kW | −28% | 1.94 | |
| 17°Fone compressor speed | 10,8003.17 kW | −14% | NR | |
| 47°Fone compressor speed | 17,4005.10 kW | −3% | NR | |
| 95°Fcooling, full load | 18,0005.28 kW | — | NR |
EER2 12.5 in that test. SEER2 15.2 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 1.22kW
- Electrical input in the 95°F cooling test
- 1.44kW
- Seasonal average heating COP
- 2.29
These exclude backup resistance heat.
How it compares with other 18,000 Btu heat pumps
1.5-ton central models
- This pairing at 5°F
- 8,100 Btu/h2.37 kWNR
- This unit at 5°F median across its pairings
- 8,100 Btu/h2.37 kW
- Median of 1.5-ton central models at 5°F
- 11,200 Btu/h3.28 kW
- Models in this group
- 243
This unit is above 5% of them, at number 231 of 243 by heat at 5°F. The middle half of the group runs 8,600 to 18,000 Btu/h.
Closest models by heat at 5°F
- BHP17L18P-**ABlueridge · 8,100 Btu/h
- MHP17018A-**AMRCOOL · 8,100 Btu/h
- ML17XP1-018-230ALennox · 8,100 Btu/h
- THF2B18S21Champion, Coleman + 3 more · 8,100 Btu/h
- HRG1**8S1R-**ACentury and Comfort-Aire · 8,000 Btu/h
- GLZS5BA1810AGoodman · 7,800 Btu/h
Every 18,000 Btu (1.5-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for NS17H18SA4-**A
248 pairings · 248 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F one speed | 17,400 Btu/h5.10 kWNR | 16,800–18,000 Btu/h4.92–5.28 kW |
| Heat output at 17°F full speed | 10,800 Btu/h3.17 kWNR | 10,200–12,100 Btu/h2.99–3.55 kW |
| Heat output at 5°F full speed | 8,100 Btu/h2.37 kWNR | 7,500–9,700 Btu/h2.20–2.84 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 47%NR | |
| COP at 5°F full speed | 1.94NR | 1.90–2.16 |
| HSPF2 Region IV | 7.8NR | 7.8–8.5 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 18,000 Btu/h5.28 kWNR | 18,000 Btu/h5.28 kW |
| EER2 at 95°F | 12.5NR | 12.2–14.0 |
| SEER2 cooling season | 15.2NR | 15.2–16.8 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-410A | |
| Compressor | Single stage | |
| Indoor unit | NCUU30BP4+TDR+TXV | 32 indoor units |
| Furnace | NF80U090S4B-* | 62 furnaces |
| Cold-climate designation EPA's designation, as published | NC | NC |
| ENERGY STAR Most Efficient EPA's designation, as published | No | On no pairings |
| Where it is sold | United States | US and Canada |
| Model string as certified | NS17H18SA4-**A | |
Pairings, by indoor-unit class
32 indoor units · 248 certified pairings
One row per indoor unit certified with this outdoor unit.
Furnace paired · 10 indoor units
-
NCHC30BT5D-**+TDR (the pairing on screen) brand not stated 7,800 Btu/h2.29 kWat 5°F, full speed
-
NCUC30BT5D-**+TDR (the pairing on screen) brand not stated 7,800 Btu/h2.29 kWat 5°F, full speed
-
NCHC24BT5D-**+TDR (the pairing on screen) brand not stated 8,400 Btu/h2.46 kWat 5°F, full speed
-
NCHC30BT4+TDR (the pairing on screen) brand not stated 7,800 Btu/h2.29 kWat 5°F, full speed
-
NCUC24BT5D-**+TDR (the pairing on screen) brand not stated 8,400 Btu/h2.46 kWat 5°F, full speed
-
NCUC30BT4+TDR (the pairing on screen) brand not stated 7,800 Btu/h2.29 kWat 5°F, full speed
-
NCUU30BP4+TDR+TXV (the pairing on screen) brand not stated 7,800 Btu/h2.29 kWat 5°F, full speed
-
NCHC24BT4+TDR (the pairing on screen) brand not stated 8,400 Btu/h2.46 kWat 5°F, full speed
-
NCUC24BT4+TDR (the pairing on screen) brand not stated 8,400 Btu/h2.46 kWat 5°F, full speed
-
NCUU24BP4+TDR+TXV (the pairing on screen) brand not stated 8,400 Btu/h2.46 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · one speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| NCHC30BT5D-**+TDR (the pairing on screen) | — | 7,8002.29 | 17,4005.10 | 18,0005.28 | 45% | 2.00 | NC | 18 |
| NCUC30BT5D-**+TDR (the pairing on screen) | — | 7,8002.29 | 17,4005.10 | 18,0005.28 | 45% | 1.98 | NC | 18 |
| NCHC24BT5D-**+TDR (the pairing on screen) | — | 8,4002.46 | 18,0005.28 | 18,0005.28 | 47% | 2.08 | NC | 15 |
| NCHC30BT4+TDR (the pairing on screen) | — | 7,8002.29 | 17,4005.10 | 18,0005.28 | 45% | 2.00 | NC | 15 |
| NCUC24BT5D-**+TDR (the pairing on screen) | — | 8,4002.46 | 17,4005.10 | 18,0005.28 | 48% | 2.06 | NC | 15 |
| NCUC30BT4+TDR (the pairing on screen) | — | 7,8002.29 | 17,4005.10 | 18,0005.28 | 45% | 1.98 | NC | 15 |
| NCUU30BP4+TDR+TXV (the pairing on screen) | — | 7,8002.29 | 17,4005.10 | 18,0005.28 | 45% | 1.98 | NC | 15 |
| NCHC24BT4+TDR (the pairing on screen) | — | 8,4002.46 | 18,0005.28 | 18,0005.28 | 47% | 2.08 | NC | 13 |
| NCUC24BT4+TDR (the pairing on screen) | — | 8,4002.46 | 17,4005.10 | 18,0005.28 | 48% | 2.06 | NC | 13 |
| NCUU24BP4+TDR+TXV (the pairing on screen) | — | 8,4002.46 | 17,4005.10 | 18,0005.28 | 48% | 2.06 | NC | 13 |
Sold as, and units with identical certified values
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Oct 27, 2025
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read