Heat Pump List

Tools

NS17H36SA4-**A

NS17H36SA4-**A is in the certified data.

Its certified full-speed heating output at 5°F is 16,800–19,300 Btu/h, 49–56% of its 47°F rating, depending on the pairing.

GE · central heat pump

NS17H36SA4-**A is in the certified data as of Sep 27, 2026.

305 certified pairings with 116 different figures. See all

Certified heating and cooling

Heating at 47°F

34,200

22,200 at 17°F

17,400 at 5°F

Btu/h, certified

2.12 COP at 5°F

Cooling at 95°F

36,000

Btu/h, certified

EER2 12.5 at 95°F

SEER2 15.8

Heating and cooling by outdoor temperature

Certified heating at 5, 17, and 47°F and cooling at 95°F for NS17H36SA4-**A, by outdoor temperature Heating: 17,400 Btu/h at 5°F, 22,200 Btu/h at 17°F, 34,200 Btu/h at 47°F. Cooling: 36,000 Btu/h at 95°F. The bars start at zero. Median of 3-ton central models: 26,400 Btu/h at 5°F, 26,200 Btu/h at 17°F, 35,200 Btu/h at 47°F, 35,000 Btu/h at 95°F. 0 10,000 20,000 30,000 40,000 Btu/h 17,400 5°F 22,200 17°F 34,200 47°F 36,000 95°F Outdoor temperature (°F)
  • Heating output
  • Cooling output
  • Median of 3-ton central models
  • Example heating load
  • Example cooling load
  • Frosting range, 17 to 45°F

This pairing delivers 34,200 Btu/h of heat at 47°F, 22,200 Btu/h at 17°F, and 17,400 Btu/h at 5°F, 51% of its 47°F rating. It delivers 36,000 Btu/h of cooling at 95°F. At 5°F that is 9,100 Btu/h short of the example heating load of 26,500 Btu/h; at 95°F it is 23,000 Btu/h above the example cooling load of 13,000 Btu/h.

Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at one speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 3-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.

The dashed lines are example loads for a typical area of about 1,100 sq ft where winters reach 5°F: heating runs from 26,500 Btu/h at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 13,000 Btu/h at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.

Calculate heating and cooling for your house

AHRI certificate 210262370 · listed by GE · certified Oct 27, 2025 · 15 pairings share these values

All rebate programs and their published thresholds

Certified output and power use

Certified output for the selected pairingThe four bars share one scale. The comparison is with the median of 3-ton central models. Heating tests run at 70°F indoors. The cooling test runs at 80°F indoors.
Outdoor temperature Certified outputBtu/h One scale vs class median COPat 5°F
5°Fone compressor speed 17,4005.10 kW −34% 2.12
17°Fone compressor speed 22,2006.51 kW −15% NR
47°Fone compressor speed 34,20010.02 kW −3% NR
95°Fcooling, full load 36,00010.55 kW — NR

EER2 12.5 in that test. SEER2 15.8 over the modeled cooling season.

Power use at each temperature

Electrical input in the 5°F full-speed test
2.41kW
Electrical input in the 95°F cooling test
2.88kW
Seasonal average heating COP
2.29

These exclude backup resistance heat.

Updated Sep 27, 2026 · Methodology

How it compares with other 36,000 Btu heat pumps

3-ton central models

This pairing at 5°F
17,400 Btu/h
This unit at 5°F median across its pairings
17,400 Btu/h
Median of 3-ton central models at 5°F
26,400 Btu/h
Models in this group
451

This unit is above 11% of them, at number 402 of 451 by heat at 5°F. The middle half of the group runs 18,650 to 32,000 Btu/h.

This size class is defined by cooling capacity, so cooling is not compared here.

Closest models by heat at 5°F

Every 36,000 Btu (3-ton) unit, ranked by cooling efficiency, then heating efficiency

Certified values for NS17H36SA4-**A

305 pairings · 305 AHRI certificates

This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.

Certified values for NS17H36SA4-**A
This pairingAll pairings
Heating
Heat output at 47°F one speed 34,200 Btu/h 32,400–36,000 Btu/h
Heat output at 17°F full speed 22,200 Btu/h 21,400–24,000 Btu/h
Heat output at 5°F full speed 17,400 Btu/h 16,800–19,300 Btu/h
Heat output below 5°F NR NR
Cold output 5°F output as a % of the 47°F rating 51%
COP at 5°F full speed 2.12 2.08–2.34
HSPF2 Region IV 7.8 7.8–8.7
Cooling
Cooling capacity at 95°F full-load test 36,000 Btu/h 35,200–36,000 Btu/h
EER2 at 95°F 12.5 12.2–14.0
SEER2 cooling season 15.8 15.2–16.8
Cooling at other temperatures NR NR
Equipment and listing
Refrigerant R-410A
Compressor Single stage
Indoor unit NCUU36BP4+TDR+TXV 33 indoor units
FurnaceNF97X040V3B-* 111 furnaces
Cold-climate designation EPA's designation, as published NC NC
ENERGY STAR Most Efficient EPA's designation, as published No On no pairings
Where it is sold US and Canada US and Canada
Model string as certified NS17H36SA4-**A

Pairings, by indoor-unit class

33 indoor units · 305 certified pairings

One row per indoor unit certified with this outdoor unit.

Furnace paired · 10 indoor units

  1. NCHC42CT5D-**+TDR brand not stated 18,200 Btu/hat 5°F, full speed

    23 pairings, 23 with a furnace · 47°F 33,400 Btu/h · 95°F cooling 36,000 Btu/h · Cold output 54% · COP 2.20

  2. NCHC51CT4+TDR brand not stated 17,600 Btu/hat 5°F, full speed

    23 pairings, 23 with a furnace · 47°F 33,600 Btu/h · 95°F cooling 36,000 Btu/h · Cold output 53% · COP 2.18

  3. NCHC51CT5D-**+TDR brand not stated 17,600 Btu/hat 5°F, full speed

    23 pairings, 23 with a furnace · 47°F 33,600 Btu/h · 95°F cooling 36,000 Btu/h · Cold output 53% · COP 2.18

  4. NCUC50CT5D-**+TDR brand not stated 17,300 Btu/hat 5°F, full speed

    23 pairings, 23 with a furnace · 47°F 33,000 Btu/h · 95°F cooling 35,800 Btu/h · Cold output 52% · COP 2.12

  5. NCHC48BT5D-**+TDR brand not stated 17,450 Btu/hat 5°F, full speed

    18 pairings, 18 with a furnace · 47°F 33,600 Btu/h · 95°F cooling 35,800 Btu/h · Cold output 52% · COP 2.20

  6. NCUC36BT5D-**+TDR brand not stated 17,200 Btu/hat 5°F, full speed

    18 pairings, 18 with a furnace · 47°F 33,800 Btu/h · 95°F cooling 36,000 Btu/h · Cold output 51% · COP 2.12

  7. NCHC42BT5D-**+TDR brand not stated 18,600 Btu/hat 5°F, full speed

    17 pairings, 17 with a furnace · 47°F 33,600 Btu/h · 95°F cooling 36,000 Btu/h · Cold output 55% · COP 2.24

  8. NCUC48CT5D-**+TDR brand not stated 17,000 Btu/hat 5°F, full speed

    16 pairings, 16 with a furnace · 47°F 33,800 Btu/h · 95°F cooling 36,000 Btu/h · Cold output 50% · COP 2.13

  9. NCUC50/60CT4+TDR brand not stated 17,300 Btu/hat 5°F, full speed

    16 pairings, 16 with a furnace · 47°F 33,000 Btu/h · 95°F cooling 35,800 Btu/h · Cold output 52% · COP 2.12

  10. NCHC48BT4+TDR brand not stated 17,500 Btu/hat 5°F, full speed

    15 pairings, 15 with a furnace · 47°F 33,600 Btu/h · 95°F cooling 35,800 Btu/h · Cold output 52% · COP 2.20

Indoor units in the furnace paired class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · one speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
NCHC42CT5D-**+TDR — 18,200 33,400 36,000 54% 2.20 NC 23
NCHC51CT4+TDR — 17,600 33,600 36,000 53% 2.18 NC 23
NCHC51CT5D-**+TDR — 17,600 33,600 36,000 53% 2.18 NC 23
NCUC50CT5D-**+TDR — 17,300 33,000 35,800 52% 2.12 NC 23
NCHC48BT5D-**+TDR — 17,450 33,600 35,800 52% 2.20 NC 18
NCUC36BT5D-**+TDR — 17,200 33,800 36,000 51% 2.12 NC 18
NCHC42BT5D-**+TDR — 18,600 33,600 36,000 55% 2.24 NC 17
NCUC48CT5D-**+TDR — 17,000 33,800 36,000 50% 2.13 NC 16
NCUC50/60CT4+TDR — 17,300 33,000 35,800 52% 2.12 NC 16
NCHC48BT4+TDR — 17,500 33,600 35,800 52% 2.20 NC 15

The share is heat output at 5°F divided by the 47°F rating.

Showing 10 of 33 indoor units All 305 certified pairings

Sold as, and units with identical certified values

Brands listing this model number

Model number as listed

History and definitions

History

First certified record
Most recent certified record
Measurements reported
Oct 27, 2025
Status
In the certified data

Field definitions

COP
Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
HSPF2
Heating efficiency over a typical season. Higher uses less electricity.
SEER2
Cooling efficiency over a typical season. Higher uses less electricity.
EER2
Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
Cold output
Heat output at 5°F as a percentage of the 47°F rating.
% of rating at 17°F
Heat output at 17°F as a percentage of the 47°F rating.

NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read

Cite or print this page

Heat Pump List, “NS17H36SA4-**A — certified heat output”. Certified figures dated , checked daily.