NS18H36MA4: every certified pairing

The 35 certified pairings of NS18H36MA4, with the AHRI certificate number, the indoor unit, and the certified figures.

Back to NS18H36MA4

Every certified pairing

Each certified record is an outdoor unit together with a named indoor unit, and a furnace where one is in the pairing. Change the indoor unit and the certified figures change.

Certified pairings of NS18H36MA4
AHRI reference Indoor unit Furnace 5°FBtu/h 17°FBtu/h 47°FBtu/h 95°FBtu/h · cooling COPat 5°F Cold output% of 47°F rating
209941210 NCUU24BP4+TXV NF96U045S3B-* 15,600 16,300 23,600 23,600 1.93 66%
209941211 NCUU30BP4+TXV NF96U045S3B-* 15,200 15,900 23,800 23,800 1.96 64%
209941212 NCUC24BT4 NF96U045S3B-* 15,600 16,300 23,600 23,600 1.93 66%
209941214 NCHC30BT4 NF96U045S3B-* 15,300 15,900 24,000 24,000 2.03 64%
209941221 NCUU30BP4+TXV NF96U070S3B-* 15,200 15,900 23,800 23,800 1.96 64%
209941222 NCUC30BT4 NF96U070S3B-* 15,200 15,900 23,800 23,800 1.96 64%
209941223 NCHC30BT4 NF96U070S3B-* 15,300 15,900 24,000 24,000 2.03 64%
209941241 NCUU24BP4+TXV NF96U045V3B-* 15,300 16,000 23,200 23,200 1.93 66%
209941242 NCUC24BT4 NF96U045V3B-* 15,300 16,000 23,200 23,200 1.93 66%
209941249 NCUU24BP4+TXV NF96U070V3B-* 15,200 15,900 23,200 23,200 1.93 66%
209941250 NCUU30BP4+TXV NF96U070V3B-* 14,800 15,500 23,400 23,400 1.97 63%
209941251 NCUC24BT4 NF96U070V3B-* 15,200 15,900 23,200 23,200 1.93 66%
209941252 NCUC30BT4 NF96U070V3B-* 14,800 15,500 23,400 23,400 1.97 63%
209941275 NAM36V1TA4-** — 18,100 22,000 34,000 34,000 2.16 53%
209941279 NAM42V1TA4-** — 18,200 22,200 34,400 34,400 2.18 53%
209941280 NAM18P1TA4 — 14,700 15,400 22,000 22,000 1.94 67%
209941282 NAM24E1TA4-** — 14,900 15,000 23,000 23,000 1.85 65%
209941283 NAM30E1TA4-** — 15,300 15,900 24,000 24,000 2.00 64%
209941284 NAM18V1TA4-** — 15,200 15,900 23,400 23,400 2.04 65%
209941285 NAM24V1TA4-** — 15,400 16,100 23,400 23,400 1.88 66%
209941310 NCUU24BP4+TXV NF96U070S3B-* 15,600 16,300 23,600 23,600 1.94 66%
209941311 NCUC24BT4 NF96U070S3B-* 15,600 16,300 23,600 23,600 1.94 66%
209941312 NCUU30BP4+TXV NF96U045V3B-* 14,900 15,600 23,400 23,400 1.96 64%
209941313 NCUC30BT4 NF96U045V3B-* 14,900 15,600 23,400 23,400 1.96 64%
209941314 NCHC30BT4 NF96U045V3B-* 15,000 15,600 23,600 23,600 2.03 64%
209941315 NCHC30BT4 NF96U070V3B-* 14,900 15,500 23,800 23,800 2.04 63%
209941316 NAM30V1TA4-** — 15,200 15,900 23,600 23,600 1.98 64%
213255776 NAM24V2TA4 — 14,500 15,200 23,000 23,000 1.94 63%
213255777 NAM30V2TA4 — 15,300 16,000 23,200 23,200 2.14 66%
213255778 NAM36V2TA4 — 18,400 22,600 33,600 33,600 2.12 55%
215835864 NCHC30BT4+TDR NF98U070M3B 14,900 15,500 23,600 23,600 2.04 63%
215835871 NCHC30BT5D-**+TDR NF98U070M3B 14,900 15,500 23,600 23,600 2.04 63%
215835896 NCUC30BT4+TDR NF98U070M3B 14,800 15,500 23,400 23,400 1.97 63%
215835899 NCUC30BT5D-**+TDR NF98U070M3B 14,800 15,500 23,400 23,400 1.97 63%
215835963 NCUU30BP4+TDR+TXV NF98U070M3B 14,800 15,500 23,400 23,400 1.97 63%

The share is heat output at 5°F divided by the 47°F rating. Tests use different compressor speeds.

35 of 35 certified pairings