NS21H60MA5-**A

NS21H60MA5-**A is in the certified data.

Its certified full-speed heating output at 5°F is 31,200–38,500 Btu/h, 58–73% of its 47°F rating (tests at different compressor speeds), depending on the pairing.

GE · central heat pump

NS21H60MA5-**A is in the certified data as of Sep 19, 2026.

51 certified pairings with 45 different figures. See all

Certified heating and cooling

Heating at 47°F

53,500

44,000 at 17°F

35,000 at 5°F

Btu/h, certified

2.14 COP at 5°F

Cooling at 95°F

56,000

Btu/h, certified

EER2 11.5 at 95°F

SEER2 19.0

Heating and cooling by outdoor temperature

Certified heating at 5, 17, and 47°F and cooling at 95°F for NS21H60MA5-**A, by outdoor temperature Heating: 35,000 Btu/h at 5°F, 44,000 Btu/h at 17°F, 53,500 Btu/h at 47°F. Cooling: 56,000 Btu/h at 95°F. The bars start at zero. Median of 4.5-ton central models: 40,000 Btu/h at 5°F, 37,800 Btu/h at 17°F, 56,000 Btu/h at 47°F, 55,000 Btu/h at 95°F. 0 20,000 40,000 60,000 Btu/h 35,000 5°F 44,000 17°F 53,500 47°F 56,000 95°F Outdoor temperature (°F)
  • Heating output
  • Cooling output
  • Median of 4.5-ton central models
  • Example heating load
  • Example cooling load
  • Frosting range, 17 to 45°F

This pairing delivers 53,500 Btu/h of heat at 47°F, 44,000 Btu/h at 17°F, and 35,000 Btu/h at 5°F, 65% of its 47°F rating. It delivers 56,000 Btu/h of cooling at 95°F. At 5°F that is 5,000 Btu/h short of the example heating load of 40,000 Btu/h; at 95°F it is 36,000 Btu/h above the example cooling load of 20,000 Btu/h.

Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 4.5-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.

The dashed lines are example loads for a typical area of about 1,650 sq ft where winters reach 5°F: heating runs from 40,000 Btu/h at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 20,000 Btu/h at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.

Calculate heating and cooling for your house

AHRI certificate 217642502 · listed by GE · certified Oct 27, 2025 · 1 pairing carries these values

All rebate programs and their published thresholds

Certified output and power use

Certified output for the selected pairingThe four bars share one scale. The comparison is with the median of 4.5-ton central models. Heating tests run at 70°F indoors. The cooling test runs at 80°F indoors.
Outdoor temperature Certified outputBtu/h One scale vs class median COPat 5°F
5°Ffull speed 35,00010.26 kW −13% 2.14
17°Ffull speed 44,00012.90 kW +16% NR
47°Fnormal speed 53,50015.68 kW −4% NR
95°Fcooling, full load 56,00016.41 kW — NR

EER2 11.5 in that test. SEER2 19.0 over the modeled cooling season.

Power use at each temperature

Electrical input in the 5°F full-speed test
4.79kW
Electrical input in the 95°F cooling test
4.87kW
Seasonal average heating COP
2.49

These exclude backup resistance heat.

Updated Sep 19, 2026 · Methodology

How it compares with other 54,000 Btu heat pumps

4.5-ton central models

This pairing at 5°F
35,000 Btu/h
This unit at 5°F median across its pairings
35,000 Btu/h
Median of 4.5-ton central models at 5°F
40,000 Btu/h
Models in this group
343

This unit is above 29% of them, at number 245 of 343 by heat at 5°F. The middle half of the group runs 32,000 to 45,000 Btu/h.

This size class is defined by cooling capacity, so cooling is not compared here.

Closest models by heat at 5°F

Every 54,000 Btu (4.5-ton) unit, ranked by cooling efficiency, then heating efficiency

Certified values for NS21H60MA5-**A

51 pairings · 51 AHRI certificates

This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.

Certified values for NS21H60MA5-**A
This pairingAll pairings
Heating
Heat output at 47°F normal speed 53,500 Btu/h 52,500–54,500 Btu/h
Heat output at 17°F full speed 44,000 Btu/h 40,000–46,000 Btu/h
Heat output at 5°F full speed 35,000 Btu/h 31,200–38,500 Btu/h
Heat output below 5°F NR NR
Cold output 5°F output as a % of the 47°F rating 65%
COP at 5°F full speed 2.14 2.06–2.16
HSPF2 Region IV 8.5 8.2–8.5
Cooling
Cooling capacity at 95°F full-load test 56,000 Btu/h 52,500–56,000 Btu/h
EER2 at 95°F 11.5 11.0–12.0
SEER2 cooling season 19.0 16.0–20.5
Cooling at other temperatures NR NR
Equipment and listing
Refrigerant R-454B
Compressor Variable speed
Indoor unit NCU[C,U]60CT5*-**+TDR 8 indoor units
FurnaceNF96U110S5C* 19 furnaces
Cold-climate designation EPA's designation, as published NC On some pairings
ENERGY STAR Most Efficient EPA's designation, as published Yes On some pairings
Where it is sold US and Canada US and Canada
Model string as certified NS21H60MA5-**A

Pairings, by indoor-unit class

8 indoor units · 51 certified pairings

One row per indoor unit certified with this outdoor unit.

Furnace paired · 4 indoor units

  1. NCHC60DT5*-**+TDR brand not stated 35,600 Btu/hat 5°F, full speed

    11 pairings, 11 with a furnace · 47°F 53,000 Btu/h · 95°F cooling 54,500 Btu/h · Cold output 67% · COP 2.08

  2. NCU[C,U]49CT5*-**+TDR brand not stated 35,700 Btu/hat 5°F, full speed

    10 pairings, 10 with a furnace · 47°F 54,500 Btu/h · 95°F cooling 55,250 Btu/h · Cold output 66% · COP 2.10

  3. NCHC48CT5*-**+TDR brand not stated 32,700 Btu/hat 5°F, full speed

    4 pairings, 4 with a furnace · 47°F 54,500 Btu/h · 95°F cooling 52,750 Btu/h · Cold output 60% · COP 2.16

  4. NCHC51CT5*-**+TDR brand not stated 31,600 Btu/hat 5°F, full speed

    2 pairings, 2 with a furnace · 47°F 54,000 Btu/h · 95°F cooling 52,500 Btu/h · Cold output 59% · COP 2.06

Indoor units in the furnace paired class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · normal speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
NCHC60DT5*-**+TDR — 35,600 53,000 54,500 67% 2.08 NC 11
NCU[C,U]49CT5*-**+TDR — 35,700 54,500 55,250 66% 2.10 NC 10
NCHC48CT5*-**+TDR — 32,700 54,500 52,750 60% 2.16 NC 4
NCHC51CT5*-**+TDR — 31,600 54,000 52,500 59% 2.06 NC 2

Air handler · 4 indoor units

  1. NCU[C,U]60CT5*-**+TDR (the pairing on screen) brand not stated 34,800 Btu/hat 5°F, full speed

    16 pairings, 15 with a furnace · 47°F 53,000 Btu/h · 95°F cooling 55,000 Btu/h · Cold output 65% · COP 2.16

  2. NCU[C,U]60DT5*-**+TDR brand not stated 34,500 Btu/hat 5°F, full speed

    6 pairings, 5 with a furnace · 47°F 53,000 Btu/h · 95°F cooling 53,000 Btu/h · Cold output 65% · COP 2.14

  3. NAM60E1TA5*-** brand not stated 38,500 Btu/hat 5°F, full speed

    1 pairing · 47°F 52,500 Btu/h · 95°F cooling 54,000 Btu/h · Cold output 73% · COP 2.16

  4. NAM60V1TA5*-** brand not stated 38,500 Btu/hat 5°F, full speed

    1 pairing · 47°F 52,500 Btu/h · 95°F cooling 54,000 Btu/h · Cold output 73% · COP 2.16

Indoor units in the air handler class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · normal speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
NCU[C,U]60CT5*-**+TDR (the pairing on screen) — 34,800 53,000 55,000 65% 2.16 NC 16
NCU[C,U]60DT5*-**+TDR — 34,500 53,000 53,000 65% 2.14 NC 6
NAM60E1TA5*-** — 38,500 52,500 54,000 73% 2.16 Yes 1
NAM60V1TA5*-** — 38,500 52,500 54,000 73% 2.16 Yes 1

The share is heat output at 5°F divided by the 47°F rating.

Showing 8 of 8 indoor units All 51 certified pairings

Sold as, and units with identical certified values

Brands listing this model number

Model number as listed

History and definitions

History

First certified record
Most recent certified record
Measurements reported
Oct 27, 2025
Status
In the certified data

Field definitions

COP
Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
HSPF2
Heating efficiency over a typical season. Higher uses less electricity.
SEER2
Cooling efficiency over a typical season. Higher uses less electricity.
EER2
Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
Cold output
Heat output at 5°F as a percentage of the 47°F rating.
% of rating at 17°F
Heat output at 17°F as a percentage of the 47°F rating.

NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read

Cite or print this page

Heat Pump List, “NS21H60MA5-**A — certified heat output”. Certified figures dated , checked daily.