NTXSKS12A112A
NTXSKS12A112A is in the certified data.
Its certified full-speed heating output at 5°F is 7,200–7,800 Btu/h2.11–2.29 kW, 52–55% of its 47°F rating (tests at different compressor speeds), depending on the pairing.
Mitsubishi Electric · mini-split heat pump
NTXSKS12A112A is in the certified data as of Sep 19, 2026. NTXSKS12A112A returned to the certified data between May 2025 and June 2025.
- 12,000 Btu (1-ton)
- Mini-split
- Variable speed
- United States
Certified heating and cooling
Heating at 47°F
13,0003.81NR
No 47°F rating for this pairing.
8,9002.61NR at 17°F
7,2002.11NR at 5°F
Btu/hkW, certified
2.00NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 13,000 Btu/h3.81 kW of heat at 47°F, 8,900 Btu/h2.61 kW at 17°F, and 7,200 Btu/h2.11 kW at 5°F, 55% of its 47°F rating. It delivers 12,000 Btu/h3.52 kW of cooling at 95°F. At 5°F that is 1,800 Btu/h0.53 kW short of the example heating load of 9,000 Btu/h2.64 kW; at 95°F it is 7,000 Btu/h2.05 kW above the example cooling load of 5,000 Btu/h1.47 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 1-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 400 sq ft where winters reach 5°F: heating runs from 9,000 Btu/h2.64 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 5,000 Btu/h1.47 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 204629287 · listed by Mitsubishi Electric · certified Jan 7, 2026 · 1 pairing carries these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 7,2002.11 kW | −22% | 2.00 | |
| 17°Ffull speed | 8,9002.61 kW | −9% | NR | |
| 47°Fnormal speed | 13,0003.81 kW | +8% | NR | |
| 95°Fcooling, full load | 12,0003.52 kW | — | NR |
EER2 13.3 in that test. SEER2 22.0 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 1.06kW
- Electrical input in the 95°F cooling test
- 0.90kW
- Seasonal average heating COP
- 2.84
These exclude backup resistance heat.
How it compares with other 12,000 Btu heat pumps
1-ton mini-split models
- This pairing at 5°F
- 7,200 Btu/h2.11 kWNR
- This unit at 5°F median across its pairings
- 7,200 Btu/h2.11 kW
- Median of 1-ton mini-split models at 5°F
- 9,200 Btu/h2.70 kW
- Models in this group
- 888
This unit is above 5% of them, at number 848 of 888 by heat at 5°F. The middle half of the group runs 8,400 to 11,300 Btu/h.
Closest models by heat at 5°F
- 4C25SCH12H11CanAir · 7,300 Btu/h
- ACIQ-12ZS-HP115C1HVAC and ACiQ · 7,300 Btu/h
- ASG24-12H1BApooDr and AproDr · 7,300 Btu/h
- SUZ-KA12NA2Mitsubishi Electric and Trane / Mitsubishi Electric · 7,200 Btu/h
- SUZ-KA12NAH2Mitsubishi Electric · 7,200 Btu/h
- MUFZ-KJ12NAHZMitsubishi Electric · 7,100 Btu/h
Every 12,000 Btu (1-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for NTXSKS12A112A
2 pairings · 2 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 13,000 Btu/h3.81 kWNR | 13,000–15,000 Btu/h3.81–4.40 kW |
| Heat output at 17°F full speed | 8,900 Btu/h2.61 kWNR | 8,900–9,900 Btu/h2.61–2.90 kW |
| Heat output at 5°F full speed | 7,200 Btu/h2.11 kWNR | 7,200–7,800 Btu/h2.11–2.29 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 55%NR | |
| COP at 5°F full speed | 2.00NR | 2.00–2.02 |
| HSPF2 Region IV | 9.7NR | 9.7–10.5 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 12,000 Btu/h3.52 kWNR | 12,000 Btu/h3.52 kW |
| EER2 at 95°F | 13.3NR | 12.7–13.3 |
| SEER2 cooling season | 22.0NR | 20.7–22.0 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-410A | |
| Compressor | Variable speed | |
| Indoor unit | SLZ-KF12NA.TH | 2 indoor units |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | NC | NC |
| ENERGY STAR Most Efficient EPA's designation, as published | No | On no pairings |
| Where it is sold | United States | United States |
| Model string as certified | NTXSKS12A112A* | |
Pairings, by indoor-unit class
2 indoor units · 2 certified pairings
One row per indoor unit certified with this outdoor unit.
Ductless indoor · 2 indoor units
-
SLZ-KF12NA.TH (the pairing on screen) Mitsubishi Electric 7,200 Btu/h2.11 kWat 5°F, full speed
-
SVZ-KP12NA (the pairing on screen) Mitsubishi Electric 7,800 Btu/h2.29 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| SLZ-KF12NA.TH (the pairing on screen) | Mitsubishi Electric | 7,2002.11 | 13,0003.81 | 12,0003.52 | 55% | 2.00 | NC | 1 |
| SVZ-KP12NA (the pairing on screen) | Mitsubishi Electric | 7,8002.29 | 15,0004.40 | 12,0003.52 | 52% | 2.02 | NC | 1 |
Sold as, and units with identical certified values
Brands listing this model number
Model number as listed
- NTXSKS12A112A* 2 pairings
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
Product history
- NTXSKS12A112A returned to the certified data between May 2025 and June 2025.
- NTXSKS12A112A was last in the certified data in records from March 2025; it was not in the list on May 20, 2025.
- NTXSKS12A112A was in the certified data by September 2024.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Jan 7, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read