The source reports COP 0.00. This is not a usable efficiency rating; efficiency and electrical-input estimates are unavailable. See our methodology.
PH5SAN430**AA*
PH5SAN430**AA* is in the certified data.
Its certified full-speed heating output at 5°F is 10,000–12,900 Btu/h2.93–3.78 kW, 36–46% of its 47°F rating, depending on the pairing.
Brock, Bryant + 2 more · central heat pump
PH5SAN430**AA* is in the certified data as of Sep 19, 2026.
- 30,000 Btu (2.5-ton)
- Central
- Single stage
- US and Canada
Certified heating and cooling
Heating at 47°F
28,0008.21NR
No 47°F rating for this pairing.
16,9004.95NR at 17°F
10,0002.93NR at 5°F
Btu/hkW, certified
0.00NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 28,000 Btu/h8.21 kW of heat at 47°F, 16,900 Btu/h4.95 kW at 17°F, and 10,000 Btu/h2.93 kW at 5°F, 36% of its 47°F rating. It delivers 27,800 Btu/h8.15 kW of cooling at 95°F. At 5°F that is 12,500 Btu/h3.66 kW short of the example heating load of 22,500 Btu/h6.59 kW; at 95°F it is 16,300 Btu/h4.78 kW above the example cooling load of 11,500 Btu/h3.37 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at one speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 2.5-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 950 sq ft where winters reach 5°F: heating runs from 22,500 Btu/h6.59 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 11,500 Btu/h3.37 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 211276150 · listed by BROCK · certified Feb 17, 2025 · 2 pairings share these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Fone compressor speed | 10,0002.93 kW | −55% | NR | |
| 17°Fone compressor speed | 16,9004.95 kW | −18% | NR | |
| 47°Fone compressor speed | 28,0008.21 kW | −7% | NR | |
| 95°Fcooling, full load | 27,8008.15 kW | — | NR |
EER2 12.5 in that test. SEER2 15.2 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- NRkW
- Electrical input in the 95°F cooling test
- 2.22kW
- Seasonal average heating COP
- 2.29
These exclude backup resistance heat.
How it compares with other 30,000 Btu heat pumps
2.5-ton central models
- This pairing at 5°F
- 10,000 Btu/h2.93 kWNR
- This unit at 5°F median across its pairings
- 10,000 Btu/h2.93 kW
- Median of 2.5-ton central models at 5°F
- 22,400 Btu/h6.56 kW
- Models in this group
- 288
This unit is above 0% of them, at number 288 of 288 by heat at 5°F. The middle half of the group runs 14,250 to 30,000 Btu/h.
Closest models by heat at 5°F
- 5TWR5030A1Trane · 13,400 Btu/h
- 5TWR6030A1Trane · 13,400 Btu/h
- GH5SAN430**AA*Bryant and Carrier · 12,900 Btu/h
- MOVA-30HN10-M152LMidea · 11,800 Btu/h
- SPHP-M-1030BBAC Pro · 11,700 Btu/h
- (C,H,T)4H5S30*K*AAA*Kenmore · 10,000 Btu/h
Every 30,000 Btu (2.5-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for PH5SAN430**AA*
4 pairings · 4 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F one speed | 28,000 Btu/h8.21 kWNR | 28,000 Btu/h8.21 kW |
| Heat output at 17°F full speed | 16,900 Btu/h4.95 kWNR | 16,900 Btu/h4.95 kW |
| Heat output at 5°F full speed | 10,000 Btu/h2.93 kWNR | 10,000–12,900 Btu/h2.93–3.78 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 36%NR | |
| COP at 5°F full speed | 0.00NR | 0.00–2.10 |
| HSPF2 Region IV | 7.8NR | 7.8 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 27,800 Btu/h8.15 kWNR | 27,800 Btu/h8.15 kW |
| EER2 at 95°F | 12.5NR | 12.5 |
| SEER2 cooling season | 15.2NR | 15.2 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-410A | |
| Compressor | Single stage | |
| Indoor unit | CAP**3721AL* | 1 indoor unit |
| Furnace | PG80ES(A,L)A60090C** | 2 furnaces |
| Cold-climate designation EPA's designation, as published | NC | NC |
| ENERGY STAR Most Efficient EPA's designation, as published | No | On no pairings |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | PH5SAN430**AA* | |
Pairings, by indoor-unit class
1 indoor unit · 4 certified pairings
One row per indoor unit certified with this outdoor unit.
Furnace paired · 1 indoor unit
-
CAP**3721AL* (the pairing on screen) brand not stated 11,450 Btu/h3.36 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · one speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| CAP**3721AL* (the pairing on screen) | — | 11,4503.36 | 28,0008.21 | 27,8008.15 | 41% | 1.05 | NC | 4 |
Sold as, and units with identical certified values
Brands listing this model number
Other brands that list these model numbers
- Are Brock and Bryant heat pumps the same?14 shared model numbers
- Are Brock and Payne heat pumps the same?14 shared model numbers
- Are Brock and WeatherMaker heat pumps the same?14 shared model numbers
- Are Bryant and WeatherMaker heat pumps the same?108 shared model numbers
- Are Bryant and Payne heat pumps the same?107 shared model numbers
Model number as listed
- PH5SAN430**AA* 4 pairings
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Feb 17, 2025
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read