Heat Pump List

Tools

PH5SAN524**AA*

Brock, Bryant + 2 more · central heat pump

PH5SAN524**AA* is in the certified data as of Sep 19, 2026. PH5SAN524**AA* changed its certified COP at 5°F on 6 pairings in the certified data between August 2025 and September 2026. The new figure is higher on 2 and lower on 4.

551 certified pairings with 130 different figures. See all

Certified heating and cooling

Heating at 47°F

23,800

14,700 at 17°F

11,400 at 5°F

Btu/h, certified

1.98 COP at 5°F

Cooling at 95°F

24,200

Btu/h, certified

EER2 12.0 at 95°F

SEER2 15.5

Heating and cooling by outdoor temperature

Certified heating at 5, 17, and 47°F and cooling at 95°F for PH5SAN524**AA*, by outdoor temperature Heating: 11,400 Btu/h at 5°F, 14,700 Btu/h at 17°F, 23,800 Btu/h at 47°F. Cooling: 24,200 Btu/h at 95°F. The bars start at zero. Median of 2-ton central models: 19,000 Btu/h at 5°F, 19,200 Btu/h at 17°F, 24,000 Btu/h at 47°F, 24,000 Btu/h at 95°F. 0 5,000 10,000 15,000 20,000 25,000 Btu/h 11,400 5°F 14,700 17°F 23,800 47°F 24,200 95°F Outdoor temperature (°F)
  • Heating output
  • Cooling output
  • Median of 2-ton central models
  • Example heating load
  • Example cooling load
  • Frosting range, 17 to 45°F

This pairing delivers 23,800 Btu/h of heat at 47°F, 14,700 Btu/h at 17°F, and 11,400 Btu/h at 5°F, 48% of its 47°F rating. It delivers 24,200 Btu/h of cooling at 95°F. At 5°F that is 7,600 Btu/h short of the example heating load of 19,000 Btu/h; at 95°F it is 14,700 Btu/h above the example cooling load of 9,500 Btu/h.

Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at one speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 2-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.

The dashed lines are example loads for a typical area of about 800 sq ft where winters reach 5°F: heating runs from 19,000 Btu/h at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 9,500 Btu/h at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.

Calculate heating and cooling for your house

AHRI certificate 214204678 · listed by BRYANT HEATING AND COOLING SYSTEMS · certified Feb 10, 2026 · 18 pairings share these values

Certified output and power use

Certified output for the selected pairingThe four bars share one scale. The comparison is with the median of 2-ton central models. Heating tests run at 70°F indoors. The cooling test runs at 80°F indoors.
Outdoor temperature Certified outputBtu/h One scale vs class median COPat 5°F
5°Fone compressor speed 11,4003.34 kW −40% 1.98
17°Fone compressor speed 14,7004.31 kW −23% NR
47°Fone compressor speed 23,8006.98 kW −1% NR
95°Fcooling, full load 24,2007.09 kW — NR

EER2 12.0 in that test. SEER2 15.5 over the modeled cooling season.

Power use at each temperature

Electrical input in the 5°F full-speed test
1.69kW
Electrical input in the 95°F cooling test
2.02kW
Seasonal average heating COP
2.29

These exclude backup resistance heat.

Updated Sep 19, 2026 · Methodology

How it compares with other 24,000 Btu heat pumps

2-ton central models

This pairing at 5°F
11,400 Btu/h
This unit at 5°F median across its pairings
11,400 Btu/h
Median of 2-ton central models at 5°F
19,000 Btu/h
Models in this group
565

This unit is above 15% of them, at number 483 of 565 by heat at 5°F. The middle half of the group runs 16,000 to 21,600 Btu/h.

This size class is defined by cooling capacity, so cooling is not compared here.

Closest models by heat at 5°F

Every 24,000 Btu (2-ton) unit, ranked by cooling efficiency, then heating efficiency

Certified values for PH5SAN524**AA*

551 pairings · 551 AHRI certificates

This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.

Certified values for PH5SAN524**AA*
This pairingAll pairings
Heating
Heat output at 47°F one speed 23,800 Btu/h 21,600–24,000 Btu/h
Heat output at 17°F full speed 14,700 Btu/h 14,200–15,200 Btu/h
Heat output at 5°F full speed 11,400 Btu/h 10,800–11,900 Btu/h
Heat output below 5°F NR NR
Cold output 5°F output as a % of the 47°F rating 48%
COP at 5°F full speed 1.98 1.96–2.26
HSPF2 Region IV 7.8 7.8–8.5
Cooling
Cooling capacity at 95°F full-load test 24,200 Btu/h 22,200–24,400 Btu/h
EER2 at 95°F 12.0 11.7–13.0
SEER2 cooling season 15.5 15.2–16.5
Cooling at other temperatures NR NR
Equipment and listing
Refrigerant R-454B
Compressor Single stage
Indoor unit CVAMA3217XMA* 29 indoor units
Furnace926SB48060V17*** 117 furnaces
Cold-climate designation EPA's designation, as published NC NC
ENERGY STAR Most Efficient EPA's designation, as published No On no pairings
Where it is sold US and Canada US and Canada
Model string as certified PH5SAN524**AA*

Pairings, by indoor-unit class

29 indoor units · 551 certified pairings

One row per indoor unit certified with this outdoor unit.

Furnace paired · 9 indoor units

  1. CAA**3721AM* brand not stated 11,600 Btu/hat 5°F, full speed

    129 pairings, 83 with a furnace · 47°F 21,800 Btu/h · 95°F cooling 24,000 Btu/h · Cold output 53% · COP 2.14

  2. CAA**2517AM* brand not stated 11,400 Btu/hat 5°F, full speed

    112 pairings, 64 with a furnace · 47°F 22,200 Btu/h · 95°F cooling 23,600 Btu/h · Cold output 51% · COP 2.10

  3. CAA**3717AM* brand not stated 11,300 Btu/hat 5°F, full speed

    107 pairings, 61 with a furnace · 47°F 22,600 Btu/h · 95°F cooling 23,400 Btu/h · Cold output 50% · COP 2.08

  4. CVAVA3817XMA* brand not stated 11,400 Btu/hat 5°F, full speed

    48 pairings, 26 with a furnace · 47°F 23,800 Btu/h · 95°F cooling 24,200 Btu/h · Cold output 48% · COP 2.00

  5. CVAMA3217XMA* (the pairing on screen) brand not stated 11,400 Btu/hat 5°F, full speed

    44 pairings, 24 with a furnace · 47°F 23,800 Btu/h · 95°F cooling 24,200 Btu/h · Cold output 48% · COP 1.98

  6. CVAVA3117XMA* brand not stated 11,300 Btu/hat 5°F, full speed

    25 pairings, 13 with a furnace · 47°F 23,800 Btu/h · 95°F cooling 24,000 Btu/h · Cold output 47% · COP 1.98

  7. CVAMA3117XMA* brand not stated 11,300 Btu/hat 5°F, full speed

    12 pairings, 6 with a furnace · 47°F 23,800 Btu/h · 95°F cooling 24,000 Btu/h · Cold output 47% · COP 1.98

  8. CAA**3617AM* brand not stated 11,000 Btu/hat 5°F, full speed

    4 pairings, 2 with a furnace · 47°F 23,000 Btu/h · 95°F cooling 22,800 Btu/h · Cold output 48% · COP 2.02

  9. CVAVA3721XMA* brand not stated 11,200 Btu/hat 5°F, full speed

    4 pairings, 2 with a furnace · 47°F 23,800 Btu/h · 95°F cooling 24,000 Btu/h · Cold output 47% · COP 1.98

Indoor units in the furnace paired class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · one speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
CAA**3721AM* — 11,600 21,800 24,000 53% 2.14 NC 129
CAA**2517AM* — 11,400 22,200 23,600 51% 2.10 NC 112
CAA**3717AM* — 11,300 22,600 23,400 50% 2.08 NC 107
CVAVA3817XMA* — 11,400 23,800 24,200 48% 2.00 NC 48
CVAMA3217XMA* (the pairing on screen) — 11,400 23,800 24,200 48% 1.98 NC 44
CVAVA3117XMA* — 11,300 23,800 24,000 47% 1.98 NC 25
CVAMA3117XMA* — 11,300 23,800 24,000 47% 1.98 NC 12
CAA**3617AM* — 11,000 23,000 22,800 48% 2.02 NC 4
CVAVA3721XMA* — 11,200 23,800 24,000 47% 1.98 NC 4

Air handler · 1 indoor unit

  1. FEVA0036**+NAVA53601CK brand not stated 11,300 Btu/hat 5°F, full speed

    4 pairings · 47°F 23,200 Btu/h · 95°F cooling 23,600 Btu/h · Cold output 49% · COP 2.04

Indoor units in the air handler class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · one speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
FEVA0036**+NAVA53601CK — 11,300 23,200 23,600 49% 2.04 NC 4

The share is heat output at 5°F divided by the 47°F rating.

Showing 10 of 29 indoor units All 551 certified pairings

Sold as, and units with identical certified values

Product history

  • PH5SAN524**AA* changed its certified COP at 5°F on 6 pairings in the certified data between August 2025 and September 2026. The new figure is higher on 2 and lower on 4.
  • PH5SAN524**AA* changed its certified heat output at 5°F on 10 pairings in the certified data between August 2025 and September 2026. The new figure is higher on 2 and lower on 8.
  • PH5SAN524**AA* changed its certified heat output at 17°F on 34 pairings in the certified data between August 2025 and September 2026. The new figure is higher on 26 and lower on 8.
  • PH5SAN524**AA* was in the certified data by September 2024.

History and definitions

History

First certified record
Most recent certified record
Measurements reported
Feb 10, 2026
Status
In the certified data

Field definitions

COP
Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
HSPF2
Heating efficiency over a typical season. Higher uses less electricity.
SEER2
Cooling efficiency over a typical season. Higher uses less electricity.
EER2
Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
Cold output
Heat output at 5°F as a percentage of the 47°F rating.
% of rating at 17°F
Heat output at 17°F as a percentage of the 47°F rating.

NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read

Cite or print this page

Heat Pump List, “PH5SAN524**AA* — certified heat output”. Certified figures dated , checked daily.
https://heatpumplist.com/model/gh5san524_st_staa_st