PHG6B481002X4
Champion, Coleman + 4 more · central heat pump
PHG6B481002X4 is in the certified data as of Sep 19, 2026.
- 48,000 Btu (4-ton)
- Central
- Two-stage
- US and Canada
Certified heating and cooling
Heating at 47°F
45,50013.33NR
No 47°F rating for this pairing.
30,2008.85NR at 17°F
24,0007.03NR at 5°F
Btu/hkW, certified
2.20NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 45,500 Btu/h13.33 kW of heat at 47°F, 30,200 Btu/h8.85 kW at 17°F, and 24,000 Btu/h7.03 kW at 5°F, 53% of its 47°F rating. It delivers 46,500 Btu/h13.63 kW of cooling at 95°F. At 5°F that is 12,500 Btu/h3.66 kW short of the example heating load of 36,500 Btu/h10.70 kW; at 95°F it is 28,500 Btu/h8.35 kW above the example cooling load of 18,000 Btu/h5.28 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at high stage; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 4-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 1,500 sq ft where winters reach 5°F: heating runs from 36,500 Btu/h10.70 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 18,000 Btu/h5.28 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 208106597 · listed by Luxaire · certified Jul 7, 2026 · 6 pairings on 6 certificates share these values
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Fone compressor speed | 24,0007.03 kW | −34% | 2.20 | |
| 17°Fone compressor speed | 30,2008.85 kW | −14% | NR | |
| 47°Fone compressor speed | 45,50013.33 kW | −5% | NR | |
| 95°Fcooling, full load | 46,50013.63 kW | — | NR |
EER2 12.0 in that test. SEER2 15.2 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 3.20kW
- Electrical input in the 95°F cooling test
- 3.88kW
- Seasonal average heating COP
- 2.11
These exclude backup resistance heat.
How it compares with other 48,000 Btu heat pumps
4-ton central models
- This pairing at 5°F
- 24,000 Btu/h7.03 kWNR
- This unit at 5°F median across its pairings
- 24,000 Btu/h7.03 kW
- Median of 4-ton central models at 5°F
- 36,400 Btu/h10.67 kW
- Models in this group
- 408
This unit is above 11% of them, at number 364 of 408 by heat at 5°F. The middle half of the group runs 25,350 to 46,000 Btu/h.
Closest models by heat at 5°F
- EL16KP1-048-230ALennox · 24,000 Btu/h
- HSA1448S1-**ACentury and Comfort-Aire · 24,000 Btu/h
- NS16H48SA5-**AGE · 24,000 Btu/h
- 7HP19V60P-**AAllied, Breeze33 + 2 more · 23,800 Btu/h
- BH719M60P-**AAC Pro, Blueridge + 1 more · 23,800 Btu/h
- EL19KPV-048-230ALennox · 23,800 Btu/h
Every 48,000 Btu (4-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for PHG6B481002X4
6 pairings · 6 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F high stage | 45,500 Btu/h13.33 kWNR | 45,500 Btu/h13.33 kW |
| Heat output at 17°F full speed | 30,200 Btu/h8.85 kWNR | 30,200 Btu/h8.85 kW |
| Heat output at 5°F full speed | 24,000 Btu/h7.03 kWNR | 24,000 Btu/h7.03 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 53%NR | |
| COP at 5°F full speed | 2.20NR | 2.20 |
| HSPF2 Region IV | 7.2NR | 7.2 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 46,500 Btu/h13.63 kWNR | 46,500 Btu/h13.63 kW |
| EER2 at 95°F | 12.0NR | 12.0 |
| SEER2 cooling season | 15.2NR | 15.2 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-410A | |
| Compressor | Two-stage | |
| Indoor unit | None listed | None |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | NC | NC |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On every pairing |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | PHG6B481002X4 | |
Pairings, by indoor-unit class
6 certified pairings
One row per indoor unit certified with this outdoor unit.
Unspecified
-
None listed (the pairing on screen) brand not stated 24,000 Btu/h7.03 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · high stage | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| None listed (the pairing on screen) | — | 24,0007.03 | 45,50013.33 | 46,50013.63 | 53% | 2.20 | NC | 6 |
Sold as, and units with identical certified values
Brands listing this model number
- Champion1 pairing
- Coleman1 pairing
- Fraser-Johnston1 pairing
- Johnson Controls1 pairing
- Luxaire1 pairing
- York1 pairing
Other brands that list these model numbers
- Are Champion and Luxaire heat pumps the same?48 shared model numbers
- Are Champion and Fraser-Johnston heat pumps the same?47 shared model numbers
- Are Champion and Coleman heat pumps the same?44 shared model numbers
- Are Champion and Johnson Controls heat pumps the same?34 shared model numbers
- Are Champion and York heat pumps the same?17 shared model numbers
- Are Coleman and Luxaire heat pumps the same?60 shared model numbers
- Are Coleman and Fraser-Johnston heat pumps the same?43 shared model numbers
Model number as listed
- PHG6B481002X4 6 pairings
Variants of the same model number
2 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
1 of 2 shown.
Other model numbers with identical certified values
2 units share this record. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
1 of 2 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
Product history
- PHG6B481002X4 first appeared in the certified data between September 2024 and November 2024.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Jul 7, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read