PUZ-A42NKA7
PUZ-A42NKA7 is in the certified data.
Its certified full-speed heating output at 5°F is 20,000 Btu/h5.86 kW, 42% of its 47°F rating (tests at different compressor speeds) across its certified pairings.
Mitsubishi Electric and Trane / Mitsubishi Electric · mini-split heat pump
PUZ-A42NKA7 is in the certified data as of Sep 19, 2026.
- 42,000 Btu (3.5-ton)
- Mini-split
- Variable speed
- United States
Certified heating and cooling
Heating at 47°F
48,00014.07NR
No 47°F rating for this pairing.
28,0008.21NR at 17°F
20,0005.86NR at 5°F
Btu/hkW, certified
2.05NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 48,000 Btu/h14.07 kW of heat at 47°F, 28,000 Btu/h8.21 kW at 17°F, and 20,000 Btu/h5.86 kW at 5°F, 42% of its 47°F rating. It delivers 42,000 Btu/h12.31 kW of cooling at 95°F. At 5°F that is 16,000 Btu/h4.69 kW short of the example heating load of 36,000 Btu/h10.55 kW; at 95°F it is 24,000 Btu/h7.03 kW above the example cooling load of 18,000 Btu/h5.28 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 3.5-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 1,500 sq ft where winters reach 5°F: heating runs from 36,000 Btu/h10.55 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 18,000 Btu/h5.28 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 201754482 · listed by Mitsubishi Electric · certified Oct 17, 2025 · 2 pairings on 2 certificates share these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 20,0005.86 kW | −44% | 2.05 | |
| 17°Ffull speed | 28,0008.21 kW | −13% | NR | |
| 47°Fnormal speed | 48,00014.07 kW | +9% | NR | |
| 95°Fcooling, full load | 42,00012.31 kW | — | NR |
EER2 11.6 in that test. SEER2 21.5 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 2.86kW
- Electrical input in the 95°F cooling test
- 3.62kW
- Seasonal average heating COP
- 2.75
These exclude backup resistance heat.
How it compares with other 42,000 Btu heat pumps
3.5-ton mini-split models
- This pairing at 5°F
- 20,000 Btu/h5.86 kWNR
- This unit at 5°F median across its pairings
- 20,000 Btu/h5.86 kW
- Median of 3.5-ton mini-split models at 5°F
- 36,000 Btu/h10.55 kW
- Models in this group
- 161
This unit is above 0% of them, at number 161 of 161 by heat at 5°F. The middle half of the group runs 33,000 to 37,000 Btu/h.
Closest models by heat at 5°F
- AOODU-1D5SAokol · 30,000 Btu/h
- YN050GLSI24M5GPioneer · 30,000 Btu/h
- MUE42HP230V1R32AOGree · 29,400 Btu/h
- YRAMG42N5HAAYork · 29,400 Btu/h
- PUZ-AK42NLMitsubishi Electric · 25,400 Btu/h
- PUZ-AK42NL2Mitsubishi Electric · 25,400 Btu/h
Every 42,000 Btu (3.5-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for PUZ-A42NKA7
2 pairings · 2 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 48,000 Btu/h14.07 kWNR | 48,000 Btu/h14.07 kW |
| Heat output at 17°F full speed | 28,000 Btu/h8.21 kWNR | 28,000 Btu/h8.21 kW |
| Heat output at 5°F full speed | 20,000 Btu/h5.86 kWNR | 20,000 Btu/h5.86 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 42%NR | |
| COP at 5°F full speed | 2.05NR | 2.05 |
| HSPF2 Region IV | 9.4NR | 9.4 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 42,000 Btu/h12.31 kWNR | 42,000 Btu/h12.31 kW |
| EER2 at 95°F | 11.6NR | 11.6 |
| SEER2 cooling season | 21.5NR | 21.5 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-410A | |
| Compressor | Variable speed | |
| Indoor unit | PLA-A42EA* | 2 indoor units |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | NC | NC |
| ENERGY STAR Most Efficient EPA's designation, as published | No | On no pairings |
| Where it is sold | United States | United States |
| Model string as certified | PUZ-A42NKA7*** | |
Pairings, by indoor-unit class
2 indoor units · 2 certified pairings
One row per indoor unit certified with this outdoor unit.
Ductless indoor · 2 indoor units
-
PLA-A42EA* (the pairing on screen) Mitsubishi Electric 20,000 Btu/h5.86 kWat 5°F, full speed
-
TPLA0A0421EA70* (the pairing on screen) Trane / Mitsubishi Electric 20,000 Btu/h5.86 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| PLA-A42EA* (the pairing on screen) | Mitsubishi Electric | 20,0005.86 | 48,00014.07 | 42,00012.31 | 42% | 2.05 | NC | 1 |
| TPLA0A0421EA70* (the pairing on screen) | Trane / Mitsubishi Electric | 20,0005.86 | 48,00014.07 | 42,00012.31 | 42% | 2.05 | NC | 1 |
Sold as, and units with identical certified values
Brands listing this model number
Other brands that list these model numbers
Model number as listed
- PUZ-A42NKA7*** 2 pairings
Variants of the same model number
2 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
1 of 2 shown.
Other model numbers with identical certified values
2 units share this record. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
1 of 2 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Oct 17, 2025
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read