Heat Pump List

Tools

PUZ-HA30NKA1

PUZ-HA30NKA1 is in the certified data.

Its certified full-speed heating output at 5°F is 18,100–32,000 Btu/h, 51–94% of its 47°F rating (tests at different compressor speeds), depending on the pairing.

Mitsubishi Electric · mini-split heat pump

PUZ-HA30NKA1 is in the certified data as of Sep 19, 2026.

6 certified pairings with 5 different figures. See all

Certified heating and cooling

Heating at 47°F

34,000

20,600 at 17°F

32,000 at 5°F

Btu/h, certified

2.00 COP at 5°F

Cooling at 95°F

30,000

Btu/h, certified

EER2 14.1 at 95°F

SEER2 20.2

Heating and cooling by outdoor temperature

Certified heating at 5, 17, and 47°F and cooling at 95°F for PUZ-HA30NKA1, by outdoor temperature Heating: 32,000 Btu/h at 5°F, 20,600 Btu/h at 17°F, 34,000 Btu/h at 47°F. Cooling: 30,000 Btu/h at 95°F. The bars start at zero. Median of 2.5-ton mini-split models: 25,000 Btu/h at 5°F, 25,600 Btu/h at 17°F, 30,000 Btu/h at 47°F, 30,000 Btu/h at 95°F. 0 10,000 20,000 30,000 40,000 Btu/h 32,000 5°F 20,600 17°F 34,000 47°F 30,000 95°F Outdoor temperature (°F)
  • Heating output
  • Cooling output
  • Median of 2.5-ton mini-split models
  • Example heating load
  • Example cooling load
  • Frosting range, 17 to 45°F

This pairing delivers 34,000 Btu/h of heat at 47°F, 20,600 Btu/h at 17°F, and 32,000 Btu/h at 5°F, 94% of its 47°F rating. It delivers 30,000 Btu/h of cooling at 95°F. At 5°F that is 7,000 Btu/h above the example heating load of 25,000 Btu/h; at 95°F it is 17,500 Btu/h above the example cooling load of 12,500 Btu/h.

Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 2.5-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.

The dashed lines are example loads for a typical area of about 1,050 sq ft where winters reach 5°F: heating runs from 25,000 Btu/h at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 12,500 Btu/h at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.

Calculate heating and cooling for your house

AHRI certificate 213617703 · listed by Mitsubishi Electric · certified Mar 31, 2025 · 1 pairing carries these values

All rebate programs and their published thresholds

Certified output and power use

Certified output for the selected pairingThe four bars share one scale. The comparison is with the median of 2.5-ton mini-split models. Heating tests run at 70°F indoors. The cooling test runs at 80°F indoors.
Outdoor temperature Certified outputBtu/h One scale vs class median COPat 5°F
5°Ffull speed 32,0009.38 kW +28% 2.00
17°Ffull speed 20,6006.04 kW −20% NR
47°Fnormal speed 34,0009.96 kW +13% NR
95°Fcooling, full load 30,0008.79 kW — NR

EER2 14.1 in that test. SEER2 20.2 over the modeled cooling season.

Power use at each temperature

Electrical input in the 5°F full-speed test
4.69kW
Electrical input in the 95°F cooling test
2.13kW
Seasonal average heating COP
2.58

These exclude backup resistance heat.

Updated Sep 19, 2026 · Methodology

How it compares with other 30,000 Btu heat pumps

2.5-ton mini-split models

This pairing at 5°F
32,000 Btu/h
This unit at 5°F median across its pairings
32,000 Btu/h
Median of 2.5-ton mini-split models at 5°F
25,000 Btu/h
Models in this group
405

This unit is above 81% of them, at number 76 of 405 by heat at 5°F. The middle half of the group runs 20,000 to 27,000 Btu/h.

This size class is defined by cooling capacity, so cooling is not compared here.

Closest models by heat at 5°F

Every 30,000 Btu (2.5-ton) unit, ranked by cooling efficiency, then heating efficiency

Certified values for PUZ-HA30NKA1

6 pairings · 6 AHRI certificates

This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.

Certified values for PUZ-HA30NKA1
This pairingAll pairings
Heating
Heat output at 47°F normal speed 34,000 Btu/h 34,000–35,800 Btu/h
Heat output at 17°F full speed 20,600 Btu/h 20,600–23,200 Btu/h
Heat output at 5°F full speed 32,000 Btu/h 18,100–32,000 Btu/h
Heat output below 5°F NR NR
Cold output 5°F output as a % of the 47°F rating 94%
COP at 5°F full speed 2.00 1.68–2.10
HSPF2 Region IV 8.8 8.5–8.8
Cooling
Cooling capacity at 95°F full-load test 30,000 Btu/h 30,000 Btu/h
EER2 at 95°F 14.1 12.0–14.1
SEER2 cooling season 20.2 15.2–20.2
Cooling at other temperatures NR NR
Equipment and listing
Refrigerant R-410A
Compressor Variable speed
Indoor unit PLA-A30EA* 6 indoor units
FurnaceNo furnace None
Cold-climate designation EPA's designation, as published Yes On some pairings
ENERGY STAR Most Efficient EPA's designation, as published Yes On some pairings
Where it is sold US and Canada US and Canada
Model string as certified PUZ-HA30NKA1***

Pairings, by indoor-unit class

6 indoor units · 6 certified pairings

One row per indoor unit certified with this outdoor unit.

Ductless indoor · 6 indoor units

  1. PAA-A30AA* Mitsubishi Electric 18,100 Btu/hat 5°F, full speed

    1 pairing · 47°F 35,800 Btu/h · 95°F cooling 30,000 Btu/h · Cold output 51% · COP 1.68

  2. PAA-A30BA* Mitsubishi Electric 18,100 Btu/hat 5°F, full speed

    1 pairing · 47°F 35,800 Btu/h · 95°F cooling 30,000 Btu/h · Cold output 51% · COP 1.68

  3. PCA-A30KA* Mitsubishi Electric 32,000 Btu/hat 5°F, full speed

    1 pairing · 47°F 35,000 Btu/h · 95°F cooling 30,000 Btu/h · Cold output 91% · COP 1.80

  4. PKA-A30KA* Mitsubishi Electric 32,000 Btu/hat 5°F, full speed

    1 pairing · 47°F 34,000 Btu/h · 95°F cooling 30,000 Btu/h · Cold output 94% · COP 1.80

  5. PLA-A30EA* (the pairing on screen) Mitsubishi Electric 32,000 Btu/hat 5°F, full speed

    1 pairing · 47°F 34,000 Btu/h · 95°F cooling 30,000 Btu/h · Cold output 94% · COP 2.00

  6. PVA-A30AA* Mitsubishi Electric 32,000 Btu/hat 5°F, full speed

    1 pairing · 47°F 34,000 Btu/h · 95°F cooling 30,000 Btu/h · Cold output 94% · COP 2.10

Indoor units in the ductless indoor class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · normal speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
PAA-A30AA* Mitsubishi Electric 18,100 35,800 30,000 51% 1.68 NC 1
PAA-A30BA* Mitsubishi Electric 18,100 35,800 30,000 51% 1.68 NC 1
PCA-A30KA* Mitsubishi Electric 32,000 35,000 30,000 91% 1.80 Yes 1
PKA-A30KA* Mitsubishi Electric 32,000 34,000 30,000 94% 1.80 Yes 1
PLA-A30EA* (the pairing on screen) Mitsubishi Electric 32,000 34,000 30,000 94% 2.00 Yes 1
PVA-A30AA* Mitsubishi Electric 32,000 34,000 30,000 94% 2.10 Yes 1

The share is heat output at 5°F divided by the 47°F rating.

Showing 6 of 6 indoor units

Sold as, and units with identical certified values

Brands listing this model number

Model number as listed

History and definitions

History

First certified record
Most recent certified record
Measurements reported
Mar 31, 2025
Status
In the certified data

Field definitions

COP
Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
HSPF2
Heating efficiency over a typical season. Higher uses less electricity.
SEER2
Cooling efficiency over a typical season. Higher uses less electricity.
EER2
Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
Cold output
Heat output at 5°F as a percentage of the 47°F rating.
% of rating at 17°F
Heat output at 17°F as a percentage of the 47°F rating.

NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read

Cite or print this page

Heat Pump List, “PUZ-HA30NKA1 — certified heat output”. Certified figures dated , checked daily.
https://heatpumplist.com/model/puz-ha30nka1