RP15AZ30AJ2N
RP15AZ30AJ2N is in the certified data.
Its certified full-speed heating output at 5°F is 14,100–24,200 Btu/h4.13–7.09 kW, 50–57% of its 47°F rating (tests at different compressor speeds), depending on the pairing.
Rheem and Ruud · central heat pump
RP15AZ30AJ2N is in the certified data as of Sep 19, 2026.
- 30,000 Btu (2.5-ton)
- Central
- Two-stage
- US and Canada
Certified heating and cooling
Heating at 47°F
28,4008.32NR
No 47°F rating for this pairing.
20,0005.86NR at 17°F
15,9004.66NR at 5°F
Btu/hkW, certified
2.10NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 28,400 Btu/h8.32 kW of heat at 47°F, 20,000 Btu/h5.86 kW at 17°F, and 15,900 Btu/h4.66 kW at 5°F, 56% of its 47°F rating. It delivers 28,400 Btu/h8.32 kW of cooling at 95°F. At 5°F that is 6,600 Btu/h1.93 kW short of the example heating load of 22,500 Btu/h6.59 kW; at 95°F it is 16,900 Btu/h4.95 kW above the example cooling load of 11,500 Btu/h3.37 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at high stage; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 2.5-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 950 sq ft where winters reach 5°F: heating runs from 22,500 Btu/h6.59 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 11,500 Btu/h3.37 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 212387089 · listed by Ruud · certified Jun 3, 2026 · 8 pairings share these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Fone compressor speed | 15,9004.66 kW | −29% | 2.10 | |
| 17°Fone compressor speed | 20,0005.86 kW | −3% | NR | |
| 47°Fone compressor speed | 28,4008.32 kW | −5% | NR | |
| 95°Fcooling, full load | 28,4008.32 kW | — | NR |
EER2 11.7 in that test. SEER2 15.2 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 2.22kW
- Electrical input in the 95°F cooling test
- 2.43kW
- Seasonal average heating COP
- 2.37
These exclude backup resistance heat.
How it compares with other 30,000 Btu heat pumps
2.5-ton central models
- This pairing at 5°F
- 15,900 Btu/h4.66 kWNR
- This unit at 5°F median across its pairings
- 15,900 Btu/h4.66 kW
- Median of 2.5-ton central models at 5°F
- 22,400 Btu/h6.56 kW
- Models in this group
- 288
This unit is above 32% of them, at number 197 of 288 by heat at 5°F. The middle half of the group runs 14,250 to 30,000 Btu/h.
Closest models by heat at 5°F
- FOP1530TJAZNAFujitsu · 15,900 Btu/h
- FWP15AZ30AJ2NFriedrich · 15,900 Btu/h
- MLP15AZ30AJ2NMainline · 15,900 Btu/h
- SP15AZ30AJ2NRussell and Sure · 15,900 Btu/h
- RHP15030B21Evcon and Guardian · 15,800 Btu/h
- YH630E2S11York · 15,600 Btu/h
Every 30,000 Btu (2.5-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for RP15AZ30AJ2N
52 pairings · 52 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F high stage | 28,400 Btu/h8.32 kWNR | 27,800–45,000 Btu/h8.15–13.19 kW |
| Heat output at 17°F full speed | 20,000 Btu/h5.86 kWNR | 18,500–30,200 Btu/h5.42–8.85 kW |
| Heat output at 5°F full speed | 15,900 Btu/h4.66 kWNR | 14,100–24,200 Btu/h4.13–7.09 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 56%NR | |
| COP at 5°F full speed | 2.10NR | 1.90–2.20 |
| HSPF2 Region IV | 8.1NR | 7.8–8.1 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 28,400 Btu/h8.32 kWNR | 27,800–45,500 Btu/h8.15–13.33 kW |
| EER2 at 95°F | 11.7NR | 11.7 |
| SEER2 cooling season | 15.2NR | 15.2–16.0 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-410A | |
| Compressor | Two-stage | |
| Indoor unit | RCFZ3617STANM | 6 indoor units |
| Furnace | R951V0703A17M4S | 19 furnaces |
| Cold-climate designation EPA's designation, as published | Yes | On some pairings |
| ENERGY STAR Most Efficient EPA's designation, as published | No | On no pairings |
| Where it is sold | United States | US and Canada |
| Model string as certified | RP15AZ30AJ2N | |
Pairings, by indoor-unit class
6 indoor units · 52 certified pairings
One row per indoor unit certified with this outdoor unit.
Furnace paired · 2 indoor units
-
RCFZ3621STANM (the pairing on screen) brand not stated 15,900 Btu/h4.66 kWat 5°F, full speed
-
RCFZ3617STANM (the pairing on screen) brand not stated 15,900 Btu/h4.66 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · high stage | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| RCFZ3621STANM (the pairing on screen) | — | 15,9004.66 | 28,4008.32 | 28,4008.32 | 56% | 2.10 | Yes | 23 |
| RCFZ3617STANM (the pairing on screen) | — | 15,9004.66 | 28,4008.32 | 28,4008.32 | 56% | 2.10 | Yes | 21 |
Air handler · 4 indoor units
-
RF2TZ3624STANS (the pairing on screen) brand not stated 14,600 Btu/h4.28 kWat 5°F, full speed
-
RH2TZ3617STANN (the pairing on screen) brand not stated 14,850 Btu/h4.35 kWat 5°F, full speed
-
RH2VZ3617STANN (the pairing on screen) brand not stated 15,600 Btu/h4.57 kWat 5°F, full speed
-
WH2TZ3617STANN (the pairing on screen) brand not stated 24,200 Btu/h7.09 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · high stage | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| RF2TZ3624STANS (the pairing on screen) | — | 14,6004.28 | 27,8008.15 | 27,8008.15 | 53% | 2.00 | NC | 2 |
| RH2TZ3617STANN (the pairing on screen) | — | 14,8504.35 | 28,4008.32 | 28,4008.32 | 52% | 2.10 | NC | 2 |
| RH2VZ3617STANN (the pairing on screen) | — | 15,6004.57 | 28,4008.32 | 28,4008.32 | 55% | 2.20 | Yes | 2 |
| WH2TZ3617STANN (the pairing on screen) | — | 24,2007.09 | 45,00013.19 | 45,50013.33 | 54% | 2.20 | Yes | 2 |
Sold as, and units with identical certified values
Brands listing this model number
Other brands that list these model numbers
Model number as listed
- RP15AZ30AJ2N 52 pairings
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Jun 3, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read