RP17AY60AJVC

RP17AY60AJVC is in the certified data.

Its certified full-speed heating output at 5°F is 39,500–45,500 Btu/h, 71–81% of its 47°F rating (tests at different compressor speeds), depending on the pairing.

Rheem and Ruud · central heat pump

RP17AY60AJVC is in the certified data as of Sep 19, 2026.

98 certified pairings with 11 different figures. See all

Certified heating and cooling

Heating at 47°F

56,000

49,500 at 17°F

45,500 at 5°F

Btu/h, certified

2.00 COP at 5°F

Cooling at 95°F

56,000

Btu/h, certified

EER2 10.0 at 95°F

SEER2 16.0

Heating and cooling by outdoor temperature

Certified heating at 5, 17, and 47°F and cooling at 95°F for RP17AY60AJVC, by outdoor temperature Heating: 45,500 Btu/h at 5°F, 49,500 Btu/h at 17°F, 56,000 Btu/h at 47°F. Cooling: 56,000 Btu/h at 95°F. The bars start at zero. Median of 4.5-ton central models: 40,000 Btu/h at 5°F, 37,800 Btu/h at 17°F, 56,000 Btu/h at 47°F, 55,000 Btu/h at 95°F. 0 20,000 40,000 60,000 Btu/h 45,500 5°F 49,500 17°F 56,000 47°F 56,000 95°F Outdoor temperature (°F)
  • Heating output
  • Cooling output
  • Median of 4.5-ton central models
  • Example heating load
  • Example cooling load
  • Frosting range, 17 to 45°F

This pairing delivers 56,000 Btu/h of heat at 47°F, 49,500 Btu/h at 17°F, and 45,500 Btu/h at 5°F, 81% of its 47°F rating. It delivers 56,000 Btu/h of cooling at 95°F. At 5°F that is 5,500 Btu/h above the example heating load of 40,000 Btu/h; at 95°F it is 36,000 Btu/h above the example cooling load of 20,000 Btu/h.

Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 4.5-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.

The dashed lines are example loads for a typical area of about 1,650 sq ft where winters reach 5°F: heating runs from 40,000 Btu/h at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 20,000 Btu/h at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.

Calculate heating and cooling for your house

AHRI certificate 218160551 · listed by Rheem · certified Sep 15, 2026 · 20 pairings share these values

All rebate programs and their published thresholds

Certified output and power use

Certified output for the selected pairingThe four bars share one scale. The comparison is with the median of 4.5-ton central models. Heating tests run at 70°F indoors. The cooling test runs at 80°F indoors.
Outdoor temperature Certified outputBtu/h One scale vs class median COPat 5°F
5°Ffull speed 45,50013.33 kW +14% 2.00
17°Ffull speed 49,50014.51 kW +31% NR
47°Fnormal speed 56,00016.41 kW 0% NR
95°Fcooling, full load 56,00016.41 kW — NR

EER2 10.0 in that test. SEER2 16.0 over the modeled cooling season.

Power use at each temperature

Electrical input in the 5°F full-speed test
6.67kW
Electrical input in the 95°F cooling test
5.60kW
Seasonal average heating COP
2.78

These exclude backup resistance heat.

Updated Sep 19, 2026 · Methodology

How it compares with other 54,000 Btu heat pumps

4.5-ton central models

This pairing at 5°F
45,500 Btu/h
This unit at 5°F median across its pairings
45,500 Btu/h
Median of 4.5-ton central models at 5°F
40,000 Btu/h
Models in this group
343

This unit is above 76% of them, at number 83 of 343 by heat at 5°F. The middle half of the group runs 32,000 to 45,000 Btu/h.

This size class is defined by cooling capacity, so cooling is not compared here.

Closest models by heat at 5°F

Every 54,000 Btu (4.5-ton) unit, ranked by cooling efficiency, then heating efficiency

Certified values for RP17AY60AJVC

98 pairings · 98 AHRI certificates

This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.

Certified values for RP17AY60AJVC
This pairingAll pairings
Heating
Heat output at 47°F normal speed 56,000 Btu/h 56,000–57,000 Btu/h
Heat output at 17°F full speed 49,500 Btu/h 49,000–50,000 Btu/h
Heat output at 5°F full speed 45,500 Btu/h 39,500–45,500 Btu/h
Heat output below 5°F NR NR
Cold output 5°F output as a % of the 47°F rating 81%
COP at 5°F full speed 2.00 2.00
HSPF2 Region IV 9.5 8.5–9.5
Cooling
Cooling capacity at 95°F full-load test 56,000 Btu/h 56,000–57,000 Btu/h
EER2 at 95°F 10.0 9.8–10.5
SEER2 cooling season 16.0 16.0–17.0
Cooling at other temperatures NR NR
Equipment and listing
Refrigerant R-454B
Compressor Variable speed
Indoor unit RCFY6024STANM 2 indoor units
FurnaceR801V0755A21UHN 48 furnaces
Cold-climate designation EPA's designation, as published Yes On every pairing
ENERGY STAR Most Efficient EPA's designation, as published Yes On every pairing
Where it is sold US and Canada US and Canada
Model string as certified RP17AY60AJVC

Pairings, by indoor-unit class

2 indoor units · 98 certified pairings

One row per indoor unit certified with this outdoor unit.

Furnace paired · 1 indoor unit

  1. RCFY6024STANM (the pairing on screen) brand not stated 45,500 Btu/hat 5°F, full speed

    96 pairings, 48 with a furnace · 47°F 56,250 Btu/h · 95°F cooling 56,250 Btu/h · Cold output 81% · COP 2.00

Indoor units in the furnace paired class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · normal speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
RCFY6024STANM (the pairing on screen) — 45,500 56,250 56,250 81% 2.00 Yes 96

Air handler · 1 indoor unit

  1. RH2VY6024STACN brand not stated 44,500 Btu/hat 5°F, full speed

    2 pairings · 47°F 57,000 Btu/h · 95°F cooling 57,000 Btu/h · Cold output 78% · COP 2.00

Indoor units in the air handler class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · normal speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
RH2VY6024STACN — 44,500 57,000 57,000 78% 2.00 Yes 2

The share is heat output at 5°F divided by the 47°F rating.

Showing 2 of 2 indoor units

Sold as, and units with identical certified values

Brands listing this model number

Other brands that list these model numbers

Model number as listed

Variants of the same model number

3 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.

2 of 3 shown.

History and definitions

History

First certified record
Most recent certified record
Measurements reported
Sep 15, 2026
Status
In the certified data

Field definitions

COP
Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
HSPF2
Heating efficiency over a typical season. Higher uses less electricity.
SEER2
Cooling efficiency over a typical season. Higher uses less electricity.
EER2
Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
Cold output
Heat output at 5°F as a percentage of the 47°F rating.
% of rating at 17°F
Heat output at 17°F as a percentage of the 47°F rating.

NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read

Cite or print this page

Heat Pump List, “RP17AY60AJVC — certified heat output”. Certified figures dated , checked daily.