SH3BF4M2SX36K
SH3BF4M2SX36K is in the certified data.
Its certified ratings are 7.8–8.1 HSPF2 and 15.2 SEER2, depending on the pairing.
Nortek · central heat pump
SH3BF4M2SX36K is in the certified data as of Sep 19, 2026.
- 36,000 Btu (3-ton)
- Central
- Two-stage
- US and Canada
Certified heating and cooling
Heating at 47°F
34,60010.14NR
No 47°F rating for this pairing.
22,0006.45NR at 17°F
——NRNR at 5°F
Btu/hkW, certified
—NRNR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 34,600 Btu/h10.14 kW of heat at 47°F and 22,000 Btu/h6.45 kW at 17°F. It delivers 34,200 Btu/h10.02 kW of cooling at 95°F. At 95°F that is 21,200 Btu/h6.21 kW above the example cooling load of 13,000 Btu/h3.81 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at high stage; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 3-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 1,100 sq ft where winters reach 5°F: heating runs from 26,500 Btu/h7.77 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 13,000 Btu/h3.81 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 210487917 · listed by NORTEK GLOBAL HVAC LLC · certified Jan 31, 2025 · 2 pairings share these values
Rebates where you live
Meets the recorded equipment thresholds of 26 programs in 16 states, provinces, or territories:Colorado (1), Idaho (1), Kansas (1), Maryland (3), Michigan (2), Minnesota (2), Mississippi (1), Nevada (1), New Jersey (4), North Carolina (1), Oregon (2), Pennsylvania (3), South Carolina (1), Texas (3), Utah (1), Newfoundland and Labrador (1).
All 26 programs by state and province
Colorado
Idaho
Kansas
Maryland
- BGE Smart Energy Savers Heating and Cooling
- Delmarva Power Maryland HVAC Efficiency Program
- Pepco Maryland HVAC Efficiency Program
Michigan
Minnesota
- Wright-Hennepin Air Source Heat Pump Rebate · Wright-Hennepin Cooperative Electric Association
- Xcel Energy Minnesota Air Source Heat Pump Rebates
Mississippi
Nevada
New Jersey
- Atlantic City Electric HVAC Efficiency Program
- JCP&L Residential HVAC Rebates
- PSE&G HVAC Instant Rebates
- SAVEGREEN Hybrid Heat · New Jersey Natural Gas
North Carolina
Oregon
- Energy Trust of Oregon Heat Pump Incentives · Portland General Electric (PGE) · Pacific Power
- Idaho Power Heating and Cooling Efficiency Program
Pennsylvania
South Carolina
Texas
- Austin Energy Air Conditioning and Heat Pump Rebate
- CPS Energy SaveNow HVAC Rebate
- CenterPoint Residential Standard Offer Program · CenterPoint Energy
Utah
Newfoundland and Labrador
Threshold comparisons use the unit’s median certified figures across its pairings, not the pairing selected above. Meeting these thresholds means the equipment may qualify; it does not guarantee approval. Service-area, installation, and product-list requirements also apply.
A utility program is for that utility's customers.
Choose location
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | NR— kW | NR | NR | |
| 17°Ffull speed | 22,0006.45 kW | −16% | NR | |
| 47°Fhigh stage | 34,60010.14 kW | −2% | NR | |
| 95°Fcooling, full load | 34,20010.02 kW | — | NR |
EER2 11.7 in that test. SEER2 15.2 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- NRkW
- Electrical input in the 95°F cooling test
- 2.92kW
- Seasonal average heating COP
- 2.29
These exclude backup resistance heat.
How it compares with other 36,000 Btu heat pumps
3-ton central models
- This pairing at 5°F
- — Btu/h— kWNRNR
- This unit at 5°F median across its pairings
- NR
- Median of 3-ton central models at 5°F
- 26,400 Btu/h7.74 kW
- Models in this group
- 451
Among 36,000 Btu central models, each by its median certified pairing, highest first: HSPF2, 363rd of 467 (tied). Models without that figure are left out.
Similar ratings at 47°F
These central models share the nominal cooling size. Comparisons use each model’s median certified figures across pairings.
- 50NR-B36---30: 34,400 Btu/h at 47°F (this model: 34,600); HSPF2 7.2 (this model: 7.8).
- 50VR-K36---30: 34,400 Btu/h at 47°F (this model: 34,600); HSPF2 7.2 (this model: 7.8).
- EA-RW36DCU: 34,200 Btu/h at 47°F (this model: 34,600); HSPF2 10.2 (this model: 7.8).
Every 36,000 Btu (3-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for SH3BF4M2SX36K
4 pairings · 4 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F high stage | 34,600 Btu/h10.14 kWNR | 34,000–34,600 Btu/h9.96–10.14 kW |
| Heat output at 17°F full speed | 22,000 Btu/h6.45 kWNR | 22,000 Btu/h6.45 kW |
| Heat output at 5°F full speed | — Btu/h— kWNRNR | NR |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | —%NRNR | NR |
| COP at 5°F full speed | —NRNR | 1.75 |
| HSPF2 Region IV | 7.8NR | 7.8–8.1 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 34,200 Btu/h10.02 kWNR | 34,200–36,000 Btu/h10.02–10.55 kW |
| EER2 at 95°F | 11.7NR | 11.7 |
| SEER2 cooling season | 15.2NR | 15.2 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-410A | |
| Compressor | Two-stage | |
| Indoor unit | C74B(A,H)MX36C-B | 4 indoor units |
| Furnace | G7T(*)-V(*)B(*) | 2 furnaces |
| Cold-climate designation EPA's designation, as published | NC | NC |
| ENERGY STAR Most Efficient EPA's designation, as published | No | On no pairings |
| Where it is sold | United States | US and Canada |
| Model string as certified | SH3BF4M2SX36K | |
Across 4 certified pairings with 4 indoor models: HSPF2 7.8 with B64VMMX36K-B to 8.1 with B64VMMX48K-C; SEER2 15.2 throughout. Endpoints name one indoor model where recorded; the furnace pairing can also change the figures.
Pairings, by indoor-unit class
4 indoor units · 4 certified pairings
One row per indoor unit certified with this outdoor unit.
Furnace paired · 2 indoor units
-
C74B(A,H)MX36C-B (the pairing on screen) brand not stated NRat 5°F, full speed
-
C74B(A,H)MX36C-C (the pairing on screen) brand not stated NRat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · high stage | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| C74B(A,H)MX36C-B (the pairing on screen) | — | NR | 34,60010.14 | 34,20010.02 | NR | — | NC | 1 |
| C74B(A,H)MX36C-C (the pairing on screen) | — | NR | 34,60010.14 | 34,20010.02 | NR | — | NC | 1 |
Air handler · 2 indoor units
-
B64VMMX36K-B (the pairing on screen) brand not stated NRat 5°F, full speed
-
B64VMMX48K-C (the pairing on screen) brand not stated NRat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · high stage | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| B64VMMX36K-B (the pairing on screen) | — | NR | 34,60010.14 | 35,60010.43 | NR | — | NC | 1 |
| B64VMMX48K-C (the pairing on screen) | — | NR | 34,0009.96 | 36,00010.55 | NR | 1.75 | NC | 1 |
Sold as, and units with identical certified values
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Jan 31, 2025
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read