SHV60H2BA

SHV60H2BA is in the certified data.

Its certified full-speed heating output at 5°F is 41,000–54,000 Btu/h, 74–98% of its 47°F rating (tests at different compressor speeds), depending on the pairing.

Innovair · central heat pump

All 120 certified Innovair models

SHV60H2BA is in the certified data as of Sep 19, 2026.

6 certified pairings with 6 different figures. See all

Certified heating and cooling

Heating at 47°F

58,000

36,000 at 17°F

43,000 at 5°F

Btu/h, certified

1.83 COP at 5°F

Cooling at 95°F

47,000

Btu/h, certified

EER2 10.0 at 95°F

SEER2 15.2

Heating and cooling by outdoor temperature

Certified heating at 5, 17, and 47°F and cooling at 95°F for SHV60H2BA, by outdoor temperature Heating: 43,000 Btu/h at 5°F, 36,000 Btu/h at 17°F, 58,000 Btu/h at 47°F. Cooling: 47,000 Btu/h at 95°F. The bars start at zero. Median of 4.5-ton central models: 40,000 Btu/h at 5°F, 37,800 Btu/h at 17°F, 56,000 Btu/h at 47°F, 55,000 Btu/h at 95°F. 0 20,000 40,000 60,000 Btu/h 43,000 5°F 36,000 17°F 58,000 47°F 47,000 95°F Outdoor temperature (°F)
  • Heating output
  • Cooling output
  • Median of 4.5-ton central models
  • Example heating load
  • Example cooling load
  • Frosting range, 17 to 45°F

This pairing delivers 58,000 Btu/h of heat at 47°F, 36,000 Btu/h at 17°F, and 43,000 Btu/h at 5°F, 74% of its 47°F rating. It delivers 47,000 Btu/h of cooling at 95°F. At 5°F that is 3,000 Btu/h above the example heating load of 40,000 Btu/h; at 95°F it is 27,000 Btu/h above the example cooling load of 20,000 Btu/h.

Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 4.5-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.

The dashed lines are example loads for a typical area of about 1,650 sq ft where winters reach 5°F: heating runs from 40,000 Btu/h at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 20,000 Btu/h at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.

Calculate heating and cooling for your house

AHRI certificate 216623513 · listed by Innovair · certified Mar 13, 2025 · 1 pairing carries these values

Rebates where you live

Meets the recorded equipment thresholds of 57 programs in 35 states, provinces, or territories:Alabama (1), Arizona (1), California (3), Colorado (1), Connecticut (3), Idaho (2), Illinois (1), Kansas (1), Kentucky (1), Maryland (3), Massachusetts (3), Michigan (2), Minnesota (3), Mississippi (2), Nevada (1), New Hampshire (3), New Jersey (3), New York (4), North Carolina (1), Oregon (2), Rhode Island (3), South Carolina (1), Tennessee (1), Texas (1), Utah (1), Vermont (3), Washington (3), Wisconsin (1), British Columbia (3), Manitoba (1), New Brunswick (1), Newfoundland and Labrador (1), Nova Scotia (2), Ontario (1), Yukon (2).

All 57 programs by state and province

Alabama

Arizona

California

Colorado

Connecticut

Idaho

Illinois

Kansas

Kentucky

Maryland

Massachusetts

Michigan

Minnesota

Mississippi

Nevada

New Hampshire

New Jersey

New York

North Carolina

Oregon

Rhode Island

South Carolina

Tennessee

Texas

Utah

Vermont

Washington

Wisconsin

British Columbia

Manitoba

New Brunswick

Newfoundland and Labrador

Nova Scotia

Ontario

Yukon

Threshold comparisons use the unit’s median certified figures across its pairings, not the pairing selected above. Meeting these thresholds means the equipment may qualify; it does not guarantee approval. Service-area, installation, and product-list requirements also apply.

All rebate programs and their published thresholds

Certified output and power use

Certified output for the selected pairingThe four bars share one scale. The comparison is with the median of 4.5-ton central models. Heating tests run at 70°F indoors. The cooling test runs at 80°F indoors.
Outdoor temperature Certified outputBtu/h One scale vs class median COPat 5°F
5°Ffull speed 43,00012.60 kW +8% 1.83
17°Ffull speed 36,00010.55 kW −5% NR
47°Fnormal speed 58,00017.00 kW +4% NR
95°Fcooling, full load 47,00013.77 kW — NR

EER2 10.0 in that test. SEER2 15.2 over the modeled cooling season.

Power use at each temperature

Electrical input in the 5°F full-speed test
6.89kW
Electrical input in the 95°F cooling test
4.70kW
Seasonal average heating COP
2.37

These exclude backup resistance heat.

Updated Sep 19, 2026 · Methodology

How it compares with other 54,000 Btu heat pumps

4.5-ton central models

This pairing at 5°F
43,000 Btu/h
This unit at 5°F median across its pairings
43,000 Btu/h
Median of 4.5-ton central models at 5°F
40,000 Btu/h
Models in this group
343

This unit is above 62% of them, at number 130 of 343 by heat at 5°F. The middle half of the group runs 32,000 to 45,000 Btu/h.

This size class is defined by cooling capacity, so cooling is not compared here.

Among 54,000 Btu central models, each by its median certified pairing, highest first: 5°F output as a share of its 47°F rating, 90th of 343 (tied); HSPF2, 143rd of 358 (tied). Models without that figure are left out.

Similar ratings at 47°F

These central models share the nominal cooling size. Comparisons use each model’s median certified figures across pairings.

  • WLP14AY60AJ2N: The same 55,000 Btu/h rating at 47°F; 25,800 Btu/h at 5°F (this model: 43,000).
  • WLP15AY60AJ2N: The same 55,000 Btu/h rating at 47°F; 27,600 Btu/h at 5°F (this model: 43,000).
  • MOVA-61HN10-M152L: The same 55,000 Btu/h rating at 47°F; 28,000 Btu/h at 5°F (this model: 43,000).

Closest models by heat at 5°F

Every 54,000 Btu (4.5-ton) unit, ranked by cooling efficiency, then heating efficiency

Floor area at the cold test point

The median certified output of 43,000 Btu/h at 5°F matches the size calculator’s heating estimate for these floor areas, rounded to about 10 sq ft. Each range divides that output by the climate band’s heating rates.

Floor area by climate band and house condition
Climate bandHouse conditionBtu/h per sq ftApproximate sq ft
MildDrafty, little insulation24–421,020–1,790
MildTypical16–261,650–2,690
MildTight, well insulated10–182,390–4,300
ColdDrafty, little insulation28–52830–1,540
ColdTypical18–301,430–2,390
ColdTight, well insulated12–221,950–3,580
Very coldDrafty, little insulation32–58740–1,340
Very coldTypical22–381,130–1,950
Very coldTight, well insulated16–281,540–2,690

This is an estimate, not a house-specific load calculation. Output stays at the 5°F test point for every band; it does not predict output at the band’s winter design temperature.

Certified values for SHV60H2BA

6 pairings · 6 AHRI certificates

This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.

Certified values for SHV60H2BA
This pairingAll pairings
Heating
Heat output at 47°F normal speed 58,000 Btu/h 51,000–58,000 Btu/h
Heat output at 17°F full speed 36,000 Btu/h 36,000–45,000 Btu/h
Heat output at 5°F full speed 43,000 Btu/h 41,000–54,000 Btu/h
Heat output below 5°F NR NR
Cold output 5°F output as a % of the 47°F rating 74%
COP at 5°F full speed 1.83 1.80–1.90
HSPF2 Region IV 8.1 8.1–9.5
Cooling
Cooling capacity at 95°F full-load test 47,000 Btu/h 47,000–54,000 Btu/h
EER2 at 95°F 10.0 9.9–12.0
SEER2 cooling season 15.2 15.2–17.5
Cooling at other temperatures NR NR
Equipment and listing
Refrigerant R-454B
Compressor Variable speed
Indoor unit MAC60H2428B 4 indoor units
FurnaceNo furnace 2 furnaces
Cold-climate designation EPA's designation, as published Yes On every pairing
ENERGY STAR Most Efficient EPA's designation, as published No On some pairings
Where it is sold US and Canada US and Canada
Model string as certified SHV60H2BA

Across 6 certified pairings with 4 indoor models: heat at 5°F 41,000 Btu/h with MMC60H2128B to 54,000 Btu/h with SAV60BDU; HSPF2 8.1 with MAC60H2428B to 9.5 with SAV60BDU; SEER2 15.2 with MAC60H2428B to 17.5 with SAV60BDU. Endpoints name one indoor model where recorded; the furnace pairing can also change the figures.

Pairings, by indoor-unit class

4 indoor units · 6 certified pairings

One row per indoor unit certified with this outdoor unit.

Air handler · 4 indoor units

  1. MMC60H2128B brand not stated 42,000 Btu/hat 5°F, full speed

    3 pairings, 2 with a furnace · 47°F 53,000 Btu/h · 95°F cooling 52,000 Btu/h · Cold output 80% · COP 1.80

  2. MAC60H2428B (the pairing on screen) brand not stated 43,000 Btu/hat 5°F, full speed

    1 pairing · 47°F 58,000 Btu/h · 95°F cooling 47,000 Btu/h · Cold output 74% · COP 1.83

  3. SAV60BDA brand not stated 52,000 Btu/hat 5°F, full speed

    1 pairing · 47°F 56,000 Btu/h · 95°F cooling 54,000 Btu/h · Cold output 93% · COP 1.80

  4. SAV60BDU brand not stated 54,000 Btu/hat 5°F, full speed

    1 pairing · 47°F 55,000 Btu/h · 95°F cooling 54,000 Btu/h · Cold output 98% · COP 1.90

Indoor units in the air handler class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · normal speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
MMC60H2128B — 42,000 53,000 52,000 80% 1.80 Yes 3
MAC60H2428B (the pairing on screen) — 43,000 58,000 47,000 74% 1.83 Yes 1
SAV60BDA — 52,000 56,000 54,000 93% 1.80 Yes 1
SAV60BDU — 54,000 55,000 54,000 98% 1.90 Yes 1

The share is heat output at 5°F divided by the 47°F rating.

Showing 4 of 4 indoor units

Sold as, and units with identical certified values

Brands listing this model number

Model number as listed

Variants of the same model number

2 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.

1 of 2 shown.

Other model numbers with identical certified values

2 units share this record. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.

1 of 2 shown.

History and definitions

Other SAV Series models by nominal cooling size: SHV18H2BA (18,000 Btu), SHV24H2BA (24,000 Btu), SOV24H2BA (24,000 Btu), SHV30H2BA (30,000 Btu), SHV36H2BB (36,000 Btu), SHV48H2BA (42,000 Btu), SOV48H2BA (42,000 Btu).

Other SHV Series models by nominal cooling size: SHV18H2BA (18,000 Btu), SHV24H2BA (24,000 Btu), SHV30H2BA (30,000 Btu), SHV30H2R20 (30,000 Btu), SHV36H2BB (36,000 Btu), SHV48H2BA (42,000 Btu).

History

First certified record
Most recent certified record
Measurements reported
Mar 13, 2025
Status
In the certified data

Field definitions

COP
Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
HSPF2
Heating efficiency over a typical season. Higher uses less electricity.
SEER2
Cooling efficiency over a typical season. Higher uses less electricity.
EER2
Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
Cold output
Heat output at 5°F as a percentage of the 47°F rating.
% of rating at 17°F
Heat output at 17°F as a percentage of the 47°F rating.

NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read