SUZ-KA09NA2
SUZ-KA09NA2 is in the certified data.
Its certified full-speed heating output at 5°F is 5,200–5,900 Btu/h1.52–1.73 kW, 47–49% of its 47°F rating (tests at different compressor speeds), depending on the pairing.
Mitsubishi Electric and Trane / Mitsubishi Electric · mini-split heat pump
SUZ-KA09NA2 is in the certified data as of Sep 19, 2026.
- 9,000 Btu
- Mini-split
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
12,0003.52NR
No 47°F rating for this pairing.
7,7002.26NR at 17°F
5,9001.73NR at 5°F
Btu/hkW, certified
2.75NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 12,000 Btu/h3.52 kW of heat at 47°F, 7,700 Btu/h2.26 kW at 17°F, and 5,900 Btu/h1.73 kW at 5°F, 49% of its 47°F rating. It delivers 9,000 Btu/h2.64 kW of cooling at 95°F. At 5°F that is 1,600 Btu/h0.47 kW short of the example heating load of 7,500 Btu/h2.20 kW; at 95°F it is 5,500 Btu/h1.61 kW above the example cooling load of 3,500 Btu/h1.03 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 9,000 Btu mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 300 sq ft where winters reach 5°F: heating runs from 7,500 Btu/h2.20 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 3,500 Btu/h1.03 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 207699119 · listed by Mitsubishi Electric · certified Jan 8, 2026 · 2 pairings share these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 5,9001.73 kW | −23% | 2.75 | |
| 17°Ffull speed | 7,7002.26 kW | −4% | NR | |
| 47°Fnormal speed | 12,0003.52 kW | +20% | NR | |
| 95°Fcooling, full load | 9,0002.64 kW | — | NR |
EER2 12.6 in that test. SEER2 20.2 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 0.63kW
- Electrical input in the 95°F cooling test
- 0.71kW
- Seasonal average heating COP
- 3.49
These exclude backup resistance heat.
How it compares with other 9,000 Btu heat pumps
9,000 Btu mini-split models
- This pairing at 5°F
- 5,900 Btu/h1.73 kWNR
- This unit at 5°F median across its pairings
- 5,900 Btu/h1.73 kW
- Median of 9,000 Btu mini-split models at 5°F
- 7,700 Btu/h2.26 kW
- Models in this group
- 894
This unit is above 2% of them, at number 873 of 894 by heat at 5°F. The middle half of the group runs 7,000 to 9,500 Btu/h.
Closest models by heat at 5°F
- FSHSR09B1CFriedrich, Rheem + 1 more · 6,000 Btu/h
- 1U09EH2VHEHaier · 5,900 Btu/h
- NTXSKS09A112Trane / Mitsubishi Electric · 5,900 Btu/h
- RX09BXVJUDaikin · 5,800 Btu/h
- AO-09U3R25SSHisense · 5,700 Btu/h
- AST-09UW3RGE00Hisense · 5,700 Btu/h
Every 9,000 Btu unit, ranked by cooling efficiency, then heating efficiency
Certified values for SUZ-KA09NA2
3 pairings · 3 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 12,000 Btu/h3.52 kWNR | 11,000–12,000 Btu/h3.22–3.52 kW |
| Heat output at 17°F full speed | 7,700 Btu/h2.26 kWNR | 6,900–7,700 Btu/h2.02–2.26 kW |
| Heat output at 5°F full speed | 5,900 Btu/h1.73 kWNR | 5,200–5,900 Btu/h1.52–1.73 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 49%NR | |
| COP at 5°F full speed | 2.75NR | 1.81–2.75 |
| HSPF2 Region IV | 11.9NR | 10.0–11.9 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 9,000 Btu/h2.64 kWNR | 9,000 Btu/h2.64 kW |
| EER2 at 95°F | 12.6NR | 12.6–13.4 |
| SEER2 cooling season | 20.2NR | 20.2–24.0 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-410A | |
| Compressor | Variable speed | |
| Indoor unit | MLZ-KP09NA* | 3 indoor units |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | NC | NC |
| ENERGY STAR Most Efficient EPA's designation, as published | No | On no pairings |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | SUZ-KA09NA2 | |
Pairings, by indoor-unit class
3 indoor units · 3 certified pairings
One row per indoor unit certified with this outdoor unit.
Ductless indoor · 3 indoor units
-
MLZ-KP09NA* (the pairing on screen) Mitsubishi Electric 5,900 Btu/h1.73 kWat 5°F, full speed
-
NTXUKS09A112** (the pairing on screen) Trane / Mitsubishi Electric 5,900 Btu/h1.73 kWat 5°F, full speed
-
SLZ-KF09NA* (the pairing on screen) Mitsubishi Electric 5,200 Btu/h1.52 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| MLZ-KP09NA* (the pairing on screen) | Mitsubishi Electric | 5,9001.73 | 12,0003.52 | 9,0002.64 | 49% | 2.75 | NC | 1 |
| NTXUKS09A112** (the pairing on screen) | Trane / Mitsubishi Electric | 5,9001.73 | 12,0003.52 | 9,0002.64 | 49% | 2.75 | NC | 1 |
| SLZ-KF09NA* (the pairing on screen) | Mitsubishi Electric | 5,2001.52 | 11,0003.22 | 9,0002.64 | 47% | 1.81 | NC | 1 |
Sold as, and units with identical certified values
Brands listing this model number
Other brands that list these model numbers
Model number as listed
- SUZ-KA09NA2 3 pairings
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Jan 8, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read