THH48HES2NAGOH24
THH48HES2NAGOH24 is in the certified data.
Its certified full-speed heating output at 5°F is 37,000–38,000 Btu/h10.84–11.14 kW, 79–82% of its 47°F rating (tests at different compressor speeds), depending on the pairing.
TCL · central heat pump
THH48HES2NAGOH24 is in the certified data as of Sep 19, 2026.
- 42,000 Btu (3.5-ton)
- Central
- Two-stage
- US and Canada
Certified heating and cooling
Heating at 47°F
45,00013.19NR
No 47°F rating for this pairing.
44,50013.04NR at 17°F
37,00010.84NR at 5°F
Btu/hkW, certified
1.80NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 45,000 Btu/h13.19 kW of heat at 47°F, 44,500 Btu/h13.04 kW at 17°F, and 37,000 Btu/h10.84 kW at 5°F, 82% of its 47°F rating. It delivers 41,000 Btu/h12.02 kW of cooling at 95°F. At 5°F that is 4,000 Btu/h1.17 kW above the example heating load of 33,000 Btu/h9.67 kW; at 95°F it is 24,000 Btu/h7.03 kW above the example cooling load of 17,000 Btu/h4.98 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at high stage; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 3.5-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 1,400 sq ft where winters reach 5°F: heating runs from 33,000 Btu/h9.67 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 17,000 Btu/h4.98 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 217361688 · listed by TCL · certified Sep 3, 2025 · 5 pairings share these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 37,00010.84 kW | +12% | 1.80 | |
| 17°Ffull speed | 44,50013.04 kW | +44% | NR | |
| 47°Fhigh stage | 45,00013.19 kW | +2% | NR | |
| 95°Fcooling, full load | 41,00012.02 kW | — | NR |
EER2 10.8 in that test. SEER2 15.2 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 6.02kW
- Electrical input in the 95°F cooling test
- 3.80kW
- Seasonal average heating COP
- 2.37
These exclude backup resistance heat.
How it compares with other 42,000 Btu heat pumps
3.5-ton central models
- This pairing at 5°F
- 37,000 Btu/h10.84 kWNR
- This unit at 5°F median across its pairings
- 37,000 Btu/h10.84 kW
- Median of 3.5-ton central models at 5°F
- 33,000 Btu/h9.67 kW
- Models in this group
- 222
This unit is above 63% of them, at number 83 of 222 by heat at 5°F. The middle half of the group runs 20,000 to 40,000 Btu/h.
Closest models by heat at 5°F
- RD18AY48AJVCFriedrich, Rheem + 3 more · 37,600 Btu/h
- 5HPL5048A1American Standard and Trane · 37,000 Btu/h
- H5H3V48*K*AAA*ACiQ, Airquest + 2 more · 37,000 Btu/h
- RP17AY48AJVCRheem and Ruud · 36,800 Btu/h
- SL25XPV-048-230ALennox · 36,800 Btu/h
- 27VNA348A*030*Carrier · 36,600 Btu/h
Every 42,000 Btu (3.5-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for THH48HES2NAGOH24
22 pairings · 22 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F high stage | 45,000 Btu/h13.19 kWNR | 45,000–48,000 Btu/h13.19–14.07 kW |
| Heat output at 17°F full speed | 44,500 Btu/h13.04 kWNR | 42,000–46,000 Btu/h12.31–13.48 kW |
| Heat output at 5°F full speed | 37,000 Btu/h10.84 kWNR | 37,000–38,000 Btu/h10.84–11.14 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 82%NR | |
| COP at 5°F full speed | 1.80NR | 1.75–1.80 |
| HSPF2 Region IV | 8.1NR | 8.1 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 41,000 Btu/h12.02 kWNR | 41,000–46,000 Btu/h12.02–13.48 kW |
| EER2 at 95°F | 10.8NR | 10.7–11.7 |
| SEER2 cooling season | 15.2NR | 15.2–16.0 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-454B | |
| Compressor | Two-stage | |
| Indoor unit | 5PXCBD06AS3+P0V0B000M40SD | 13 indoor units |
| Furnace | No furnace | 10 furnaces |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | No | On no pairings |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | THH48HES2NAGOH24 | |
Pairings, by indoor-unit class
13 indoor units · 22 certified pairings
One row per indoor unit certified with this outdoor unit.
Furnace paired · 7 indoor units
-
5PXCCD07AS3 (the pairing on screen) brand not stated 37,000 Btu/h10.84 kWat 5°F, full speed
-
5TXCC007AS3 (the pairing on screen) brand not stated 37,000 Btu/h10.84 kWat 5°F, full speed
-
5PXCBD06AS3 (the pairing on screen) brand not stated 37,000 Btu/h10.84 kWat 5°F, full speed
-
5PXCDD10AS3 (the pairing on screen) brand not stated 37,000 Btu/h10.84 kWat 5°F, full speed
-
5TXCC009AS3 (the pairing on screen) brand not stated 37,000 Btu/h10.84 kWat 5°F, full speed
-
5TXCD008AS3 (the pairing on screen) brand not stated 37,000 Btu/h10.84 kWat 5°F, full speed
-
5TXCD010AS3 (the pairing on screen) brand not stated 37,000 Btu/h10.84 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · high stage | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| 5PXCCD07AS3 (the pairing on screen) | — | 37,00010.84 | 46,00013.48 | 41,25012.09 | 80% | 1.80 | Yes | 4 |
| 5TXCC007AS3 (the pairing on screen) | — | 37,00010.84 | 46,00013.48 | 41,00012.02 | 80% | 1.80 | Yes | 3 |
| 5PXCBD06AS3 (the pairing on screen) | — | 37,00010.84 | 46,00013.48 | 41,00012.02 | 80% | 1.80 | Yes | 2 |
| 5PXCDD10AS3 (the pairing on screen) | — | 37,00010.84 | 46,00013.48 | 41,50012.16 | 80% | 1.80 | Yes | 2 |
| 5TXCC009AS3 (the pairing on screen) | — | 37,00010.84 | 46,00013.48 | 41,25012.09 | 80% | 1.80 | Yes | 2 |
| 5TXCD008AS3 (the pairing on screen) | — | 37,00010.84 | 46,00013.48 | 41,50012.16 | 80% | 1.80 | Yes | 2 |
| 5TXCD010AS3 (the pairing on screen) | — | 37,00010.84 | 46,00013.48 | 41,50012.16 | 80% | 1.80 | Yes | 1 |
Air handler · 6 indoor units
-
5PXCBD06AS3+P0V0B000M40SD (the pairing on screen) brand not stated 37,000 Btu/h10.84 kWat 5°F, full speed
-
5PXCCD09AS3+P0V0C000M50SD (the pairing on screen) brand not stated 37,000 Btu/h10.84 kWat 5°F, full speed
-
5TEM6D06AV41+TDR (the pairing on screen) brand not stated 38,000 Btu/h11.14 kWat 5°F, full speed
-
5TXCB006AS3+P0V0B000M40SD (the pairing on screen) brand not stated 37,000 Btu/h10.84 kWat 5°F, full speed
-
5TXCC007AS3+P0V0C000M50SD (the pairing on screen) brand not stated 37,000 Btu/h10.84 kWat 5°F, full speed
-
5TXCD008AS3+P0V0D000M50SD (the pairing on screen) brand not stated 37,000 Btu/h10.84 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · high stage | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| 5PXCBD06AS3+P0V0B000M40SD (the pairing on screen) | — | 37,00010.84 | 45,00013.19 | 41,00012.02 | 82% | 1.80 | Yes | 1 |
| 5PXCCD09AS3+P0V0C000M50SD (the pairing on screen) | — | 37,00010.84 | 45,00013.19 | 41,00012.02 | 82% | 1.80 | Yes | 1 |
| 5TEM6D06AV41+TDR (the pairing on screen) | — | 38,00011.14 | 48,00014.07 | 46,00013.48 | 79% | 1.75 | Yes | 1 |
| 5TXCB006AS3+P0V0B000M40SD (the pairing on screen) | — | 37,00010.84 | 45,00013.19 | 41,00012.02 | 82% | 1.80 | Yes | 1 |
| 5TXCC007AS3+P0V0C000M50SD (the pairing on screen) | — | 37,00010.84 | 45,00013.19 | 41,00012.02 | 82% | 1.80 | Yes | 1 |
| 5TXCD008AS3+P0V0D000M50SD (the pairing on screen) | — | 37,00010.84 | 45,00013.19 | 41,00012.02 | 82% | 1.80 | Yes | 1 |
Sold as, and units with identical certified values
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
Product history
- THH48HES2NAGOH24 first appeared in the certified data between September 2024 and November 2024.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Sep 3, 2025
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read