TMH18HDI2NAO0U
TCL · mini-split heat pump
TMH18HDI2NAO0U is in the certified data as of Sep 19, 2026.
- 18,000 Btu (1.5-ton)
- Mini-split
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
18,0005.28NR
No 47°F rating for this pairing.
14,0004.10NR at 17°F
14,0004.10NR at 5°F
Btu/hkW, certified
2.00NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 18,000 Btu/h5.28 kW of heat at 47°F, 14,000 Btu/h4.10 kW at 17°F, and 14,000 Btu/h4.10 kW at 5°F, 78% of its 47°F rating. It delivers 18,000 Btu/h5.28 kW of cooling at 95°F. At 5°F that matches the example heating load of 14,000 Btu/h4.10 kW; at 95°F it is 11,000 Btu/h3.22 kW above the example cooling load of 7,000 Btu/h2.05 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 1.5-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 600 sq ft where winters reach 5°F: heating runs from 14,000 Btu/h4.10 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 7,000 Btu/h2.05 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 218471023 · listed by TCL · certified Aug 20, 2026 · 1 pairing carries these values
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 14,0004.10 kW | −1% | 2.00 | |
| 17°Ffull speed | 14,0004.10 kW | −5% | NR | |
| 47°Fnormal speed | 18,0005.28 kW | 0% | NR | |
| 95°Fcooling, full load | 18,0005.28 kW | — | NR |
EER2 11.7 in that test. SEER2 25.0 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 2.05kW
- Electrical input in the 95°F cooling test
- 1.54kW
- Seasonal average heating COP
- 2.93
These exclude backup resistance heat.
How it compares with other 18,000 Btu heat pumps
1.5-ton mini-split models
- This pairing at 5°F
- 14,000 Btu/h4.10 kWNR
- This unit at 5°F median across its pairings
- 14,000 Btu/h4.10 kW
- Median of 1.5-ton mini-split models at 5°F
- 14,200 Btu/h4.16 kW
- Models in this group
- 1,110
This unit is above 43% of them, at number 630 of 1,110 by heat at 5°F. The middle half of the group runs 13,000 to 18,000 Btu/h.
Among 18,000 Btu mini-split models, each by its median certified pairing, highest first: 5°F output as a share of its 47°F rating, 540th of 1,110 (tied); HSPF2, 345th of 1,114 (tied). Models without that figure are left out.
Similar ratings at 47°F
These mini-split models share the nominal cooling size. Comparisons use each model’s median certified figures across pairings.
- RAC-PH18WHLAE: The same 18,000 Btu/h rating at 47°F; 23,000 Btu/h at 5°F (this model: 14,000).
- AOU18RLXFZH: The same 18,000 Btu/h rating at 47°F; 22,000 Btu/h at 5°F (this model: 14,000).
- AM2-H18/2DR3B: The same 18,000 Btu/h rating at 47°F; 21,800 Btu/h at 5°F (this model: 14,000).
Closest models by heat at 5°F
- MULTI3-18HP230C-OMRCOOL · 14,000 Btu/h
- RV-18M2/O-RRovsun · 14,000 Btu/h
- SAK-18-DT2/220VStar Air Kontrol · 14,000 Btu/h
- YRAMG18N2HAAYork · 14,000 Btu/h
- EMH-2O18KBBEco AC · 13,800 Btu/h
- MUE18HP230V1R32AOGree · 13,800 Btu/h
Every 18,000 Btu (1.5-ton) unit, ranked by cooling efficiency, then heating efficiency
Floor area at the cold test point
The median certified output of 14,000 Btu/h at 5°F matches the size calculator’s heating estimate for these floor areas, rounded to about 10 sq ft. Each range divides that output by the climate band’s heating rates.
| Climate band | House condition | Btu/h per sq ft | Approximate sq ft |
|---|---|---|---|
| Mild | Drafty, little insulation | 24–42 | 330–580 |
| Mild | Typical | 16–26 | 540–880 |
| Mild | Tight, well insulated | 10–18 | 780–1,400 |
| Cold | Drafty, little insulation | 28–52 | 270–500 |
| Cold | Typical | 18–30 | 470–780 |
| Cold | Tight, well insulated | 12–22 | 640–1,170 |
| Very cold | Drafty, little insulation | 32–58 | 240–440 |
| Very cold | Typical | 22–38 | 370–640 |
| Very cold | Tight, well insulated | 16–28 | 500–880 |
This is an estimate, not a house-specific load calculation. Output stays at the 5°F test point for every band; it does not predict output at the band’s winter design temperature.
Certified values for TMH18HDI2NAO0U
1 pairing · 1 AHRI certificate
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 18,000 Btu/h5.28 kWNR | 18,000 Btu/h5.28 kW |
| Heat output at 17°F full speed | 14,000 Btu/h4.10 kWNR | 14,000 Btu/h4.10 kW |
| Heat output at 5°F full speed | 14,000 Btu/h4.10 kWNR | 14,000 Btu/h4.10 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 78%NR | |
| COP at 5°F full speed | 2.00NR | 2.00 |
| HSPF2 Region IV | 10.0NR | 10.0 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 18,000 Btu/h5.28 kWNR | 18,000 Btu/h5.28 kW |
| EER2 at 95°F | 11.7NR | 11.7 |
| SEER2 cooling season | 25.0NR | 25.0 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-32 | |
| Compressor | Variable speed | |
| Indoor unit | None listed | None |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On every pairing |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | TMH18HDI2NAO0U* | |
Pairings, by indoor-unit class
1 certified pairing
One row per indoor unit certified with this outdoor unit.
Ductless indoor
-
None listed (the pairing on screen) TCL 14,000 Btu/h4.10 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| None listed (the pairing on screen) | TCL | 14,0004.10 | 18,0005.28 | 18,0005.28 | 78% | 2.00 | Yes | 1 |
Sold as, and units with identical certified values
Variants of the same model number
6 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
5 of 6 shown.
Other model numbers with identical certified values
6 units share this record. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
- BI08W6-1B5A0identical certified values
- CMBA18TP2AU-Widentical certified values
- F18FMH24XQCidentical certified values
- H18FMH24XQCidentical certified values
- Z2SOV-18HDTA-US-Oidentical certified values
5 of 6 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
History and definitions
Other free matcht 24S R32 models by nominal cooling size: H18FMH24XQC (18,000 Btu), TMH18HDI2NAO0U25 (18,000 Btu), TMH27HDI2NAO0U25 (24,000 Btu), H27FMH24XQC (30,000 Btu), H36FMH22XQC (36,000 Btu), TMH42HDI2NAO0U25 (36,000 Btu), H42FMH22XQC (42,000 Btu).
History
- First certified record
- Most recent certified record
- Measurements reported
- Aug 20, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read