TMH18HEI2NAS0U25
TCL · mini-split heat pump
TMH18HEI2NAS0U25 is in the certified data as of Sep 19, 2026.
- 18,000 Btu (1.5-ton)
- Mini-split
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
19,0005.57NR
No 47°F rating for this pairing.
22,2006.51NR at 17°F
19,3005.66NR at 5°F
Btu/hkW, certified
1.90NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 19,000 Btu/h5.57 kW of heat at 47°F, 22,200 Btu/h6.51 kW at 17°F, and 19,300 Btu/h5.66 kW at 5°F, 102% of its 47°F rating. It delivers 19,000 Btu/h5.57 kW of cooling at 95°F. At 5°F that is 5,300 Btu/h1.55 kW above the example heating load of 14,000 Btu/h4.10 kW; at 95°F it is 12,000 Btu/h3.52 kW above the example cooling load of 7,000 Btu/h2.05 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 1.5-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 600 sq ft where winters reach 5°F: heating runs from 14,000 Btu/h4.10 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 7,000 Btu/h2.05 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 218625171 · listed by TCL · certified Jul 17, 2026 · 1 pairing carries these values
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 19,3005.66 kW | +36% | 1.90 | |
| 17°Ffull speed | 22,2006.51 kW | +50% | NR | |
| 47°Fnormal speed | 19,0005.57 kW | +6% | NR | |
| 95°Fcooling, full load | 19,0005.57 kW | — | NR |
EER2 14.0 in that test. SEER2 24.25 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 2.98kW
- Electrical input in the 95°F cooling test
- 1.36kW
- Seasonal average heating COP
- 2.78
These exclude backup resistance heat.
How it compares with other 18,000 Btu heat pumps
1.5-ton mini-split models
- This pairing at 5°F
- 19,300 Btu/h5.66 kWNR
- This unit at 5°F median across its pairings
- 19,300 Btu/h5.66 kW
- Median of 1.5-ton mini-split models at 5°F
- 14,200 Btu/h4.16 kW
- Models in this group
- 1,110
This unit is above 89% of them, at number 118 of 1,110 by heat at 5°F. The middle half of the group runs 13,000 to 18,000 Btu/h.
Among 18,000 Btu mini-split models, each by its median certified pairing, highest first: 5°F output as a share of its 47°F rating, 80th of 1,110; HSPF2, 637th of 1,114 (tied). Models without that figure are left out.
Similar ratings at 47°F
These mini-split models share the nominal cooling size. Comparisons use each model’s median certified figures across pairings.
- PUZ-AK18NL2: The same 19,000 Btu/h rating at 47°F; 9,200 Btu/h at 5°F (this model: 19,300).
- O-ES-18-HP-C-230B: The same 19,000 Btu/h rating at 47°F; 11,300 Btu/h at 5°F (this model: 19,300).
- 4DHP2S18S-1P: The same 19,000 Btu/h rating at 47°F; 12,700 Btu/h at 5°F (this model: 19,300).
Closest models by heat at 5°F
- ACIQ-18Z-HH-M2B1HVAC, ACiQ + 3 more · 19,300 Btu/h
- MLB018S4M-1PLennox · 19,300 Btu/h
- RUZ-AK18NLHZMitsubishi Electric · 19,300 Btu/h
- AE-X18CUSharp · 19,000 Btu/h
- AOU18RLXFWHFujitsu · 19,000 Btu/h
- CDHAMBB-18-OContinental · 19,000 Btu/h
Every 18,000 Btu (1.5-ton) unit, ranked by cooling efficiency, then heating efficiency
Floor area at the cold test point
The median certified output of 19,300 Btu/h at 5°F matches the size calculator’s heating estimate for these floor areas, rounded to about 10 sq ft. Each range divides that output by the climate band’s heating rates.
| Climate band | House condition | Btu/h per sq ft | Approximate sq ft |
|---|---|---|---|
| Mild | Drafty, little insulation | 24–42 | 460–800 |
| Mild | Typical | 16–26 | 740–1,210 |
| Mild | Tight, well insulated | 10–18 | 1,070–1,930 |
| Cold | Drafty, little insulation | 28–52 | 370–690 |
| Cold | Typical | 18–30 | 640–1,070 |
| Cold | Tight, well insulated | 12–22 | 880–1,610 |
| Very cold | Drafty, little insulation | 32–58 | 330–600 |
| Very cold | Typical | 22–38 | 510–880 |
| Very cold | Tight, well insulated | 16–28 | 690–1,210 |
This is an estimate, not a house-specific load calculation. Output stays at the 5°F test point for every band; it does not predict output at the band’s winter design temperature.
Certified values for TMH18HEI2NAS0U25
4 pairings · 4 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 19,000 Btu/h5.57 kWNR | 18,000–20,000 Btu/h5.28–5.86 kW |
| Heat output at 17°F full speed | 22,200 Btu/h6.51 kWNR | 21,400–23,000 Btu/h6.27–6.74 kW |
| Heat output at 5°F full speed | 19,300 Btu/h5.66 kWNR | 18,900–19,800 Btu/h5.54–5.80 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 102%NR | |
| COP at 5°F full speed | 1.90NR | 1.80–2.00 |
| HSPF2 Region IV | 9.5NR | 9.0–10.0 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 19,000 Btu/h5.57 kWNR | 18,000–20,000 Btu/h5.28–5.86 kW |
| EER2 at 95°F | 14.0NR | 13.0–15.0 |
| SEER2 cooling season | 24.25NR | 21.5–27.0 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-454B | |
| Compressor | Variable speed | |
| Indoor unit | None listed | None |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On every pairing |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | TMH18HEI2NAS0U25 | |
Pairings, by indoor-unit class
4 certified pairings
One row per indoor unit certified with this outdoor unit.
Ductless indoor
-
None listed (the pairing on screen) TCL 19,550 Btu/h5.73 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| None listed (the pairing on screen) | TCL | 19,5505.73 | 19,5005.71 | 19,5005.71 | 100% | 1.95 | Yes | 4 |
Sold as, and units with identical certified values
Brands listing this model number
Model number as listed
- TMH18HEI2NAS0U25 1 pairing
- TMH18HEI2NAS0U25* 3 pairings
Variants of the same model number
4 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
3 of 4 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Jul 17, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read