TRUZA0241HA70
TRUZA0241HA70 is in the certified data.
Its certified full-speed heating output at 5°F is 9,200–13,200 Btu/h2.70–3.87 kW, 32–46% of its 47°F rating (tests at different compressor speeds), depending on the pairing.
Trane / Mitsubishi Electric · mini-split heat pump
TRUZA0241HA70 is in the certified data as of Sep 19, 2026.
- 24,000 Btu (2-ton)
- Mini-split
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
28,0008.21NR
No 47°F rating for this pairing.
15,4004.51NR at 17°F
10,3003.02NR at 5°F
Btu/hkW, certified
1.99NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 28,000 Btu/h8.21 kW of heat at 47°F, 15,400 Btu/h4.51 kW at 17°F, and 10,300 Btu/h3.02 kW at 5°F, 37% of its 47°F rating. It delivers 24,000 Btu/h7.03 kW of cooling at 95°F. At 5°F that is 8,700 Btu/h2.55 kW short of the example heating load of 19,000 Btu/h5.57 kW; at 95°F it is 14,500 Btu/h4.25 kW above the example cooling load of 9,500 Btu/h2.78 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 2-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 800 sq ft where winters reach 5°F: heating runs from 19,000 Btu/h5.57 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 9,500 Btu/h2.78 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 206720330 · listed by Trane / Mitsubishi Electric · certified Dec 2, 2025 · 2 pairings share these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 10,3003.02 kW | −46% | 1.99 | |
| 17°Ffull speed | 15,4004.51 kW | −23% | NR | |
| 47°Fnormal speed | 28,0008.21 kW | +12% | NR | |
| 95°Fcooling, full load | 24,0007.03 kW | — | NR |
EER2 12.2 in that test. SEER2 21.0 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 1.52kW
- Electrical input in the 95°F cooling test
- 1.97kW
- Seasonal average heating COP
- 2.70
These exclude backup resistance heat.
How it compares with other 24,000 Btu heat pumps
2-ton mini-split models
- This pairing at 5°F
- 10,300 Btu/h3.02 kWNR
- This unit at 5°F median across its pairings
- 10,300 Btu/h3.02 kW
- Median of 2-ton mini-split models at 5°F
- 19,000 Btu/h5.57 kW
- Models in this group
- 917
This unit is above 1% of them, at number 909 of 917 by heat at 5°F. The middle half of the group runs 18,000 to 23,000 Btu/h.
Closest models by heat at 5°F
- RXF24AXVJUDaikin · 10,800 Btu/h
- PUZ-A24NHA7Mitsubishi Electric and Trane / Mitsubishi Electric · 10,300 Btu/h
- PUZ-A24NHA8Mitsubishi Electric and Trane / Mitsubishi Electric · 10,300 Btu/h
- PUZ-A24NHAMitsubishi Electric · 10,200 Btu/h
- TRUZA0241HATrane / Mitsubishi Electric · 10,200 Btu/h
- 3U24MS2HDHaier · 10,000 Btu/h
Every 24,000 Btu (2-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for TRUZA0241HA70
12 pairings · 12 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 28,000 Btu/h8.21 kWNR | 22,600–29,800 Btu/h6.62–8.73 kW |
| Heat output at 17°F full speed | 15,400 Btu/h4.51 kWNR | 13,800–15,700 Btu/h4.04–4.60 kW |
| Heat output at 5°F full speed | 10,300 Btu/h3.02 kWNR | 9,200–13,200 Btu/h2.70–3.87 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 37%NR | |
| COP at 5°F full speed | 1.99NR | 1.73–2.12 |
| HSPF2 Region IV | 9.2NR | 8.3–9.3 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 24,000 Btu/h7.03 kWNR | 18,000–24,000 Btu/h5.28–7.03 kW |
| EER2 at 95°F | 12.2NR | 12.0–14.3 |
| SEER2 cooling season | 21.0NR | 17.1–24.7 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-410A | |
| Compressor | Variable speed | |
| Indoor unit | PCA-A24KA**** | 12 indoor units |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | NC | NC |
| ENERGY STAR Most Efficient EPA's designation, as published | No | On some pairings |
| Where it is sold | United States | US and Canada |
| Model string as certified | TRUZA0241HA70** | |
Pairings, by indoor-unit class
12 indoor units · 12 certified pairings
One row per indoor unit certified with this outdoor unit.
Ductless indoor · 12 indoor units
-
PAA-A18AA* (the pairing on screen) Trane / Mitsubishi Electric 10,500 Btu/h3.08 kWat 5°F, full speed
-
PAA-A18BA* (the pairing on screen) Trane / Mitsubishi Electric 10,500 Btu/h3.08 kWat 5°F, full speed
-
PAA-A24AA* (the pairing on screen) Trane / Mitsubishi Electric 13,200 Btu/h3.87 kWat 5°F, full speed
-
PAA-A24BA* (the pairing on screen) Trane / Mitsubishi Electric 13,200 Btu/h3.87 kWat 5°F, full speed
-
PCA-A24KA**** (the pairing on screen) Trane / Mitsubishi Electric 10,300 Btu/h3.02 kWat 5°F, full speed
-
PKA-A24KA**** (the pairing on screen) Trane / Mitsubishi Electric 10,700 Btu/h3.14 kWat 5°F, full speed
-
PLA-A24EA**** (the pairing on screen) Trane / Mitsubishi Electric 9,200 Btu/h2.70 kWat 5°F, full speed
-
PVA-A24AA**** (the pairing on screen) Trane / Mitsubishi Electric 9,800 Btu/h2.87 kWat 5°F, full speed
-
TPCA0A0241KA*** (the pairing on screen) Trane / Mitsubishi Electric 10,300 Btu/h3.02 kWat 5°F, full speed
-
TPKA0A0241KA*** (the pairing on screen) Trane / Mitsubishi Electric 10,700 Btu/h3.14 kWat 5°F, full speed
-
TPLA0A0241EA*** (the pairing on screen) Trane / Mitsubishi Electric 9,200 Btu/h2.70 kWat 5°F, full speed
-
TPVA0A0241AA*** (the pairing on screen) Trane / Mitsubishi Electric 9,800 Btu/h2.87 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| PAA-A18AA* (the pairing on screen) | Trane / Mitsubishi Electric | 10,5003.08 | 22,6006.62 | 18,0005.28 | 46% | 1.76 | NC | 1 |
| PAA-A18BA* (the pairing on screen) | Trane / Mitsubishi Electric | 10,5003.08 | 22,6006.62 | 18,0005.28 | 46% | 1.76 | NC | 1 |
| PAA-A24AA* (the pairing on screen) | Trane / Mitsubishi Electric | 13,2003.87 | 29,8008.73 | 24,0007.03 | 44% | 2.12 | NC | 1 |
| PAA-A24BA* (the pairing on screen) | Trane / Mitsubishi Electric | 13,2003.87 | 29,8008.73 | 24,0007.03 | 44% | 2.12 | NC | 1 |
| PCA-A24KA**** (the pairing on screen) | Trane / Mitsubishi Electric | 10,3003.02 | 28,0008.21 | 24,0007.03 | 37% | 1.99 | NC | 1 |
| PKA-A24KA**** (the pairing on screen) | Trane / Mitsubishi Electric | 10,7003.14 | 28,0008.21 | 24,0007.03 | 38% | 2.08 | NC | 1 |
| PLA-A24EA**** (the pairing on screen) | Trane / Mitsubishi Electric | 9,2002.70 | 29,0008.50 | 24,0007.03 | 32% | 1.89 | NC | 1 |
| PVA-A24AA**** (the pairing on screen) | Trane / Mitsubishi Electric | 9,8002.87 | 28,0008.21 | 24,0007.03 | 35% | 1.77 | NC | 1 |
| TPCA0A0241KA*** (the pairing on screen) | Trane / Mitsubishi Electric | 10,3003.02 | 28,0008.21 | 24,0007.03 | 37% | 1.99 | NC | 1 |
| TPKA0A0241KA*** (the pairing on screen) | Trane / Mitsubishi Electric | 10,7003.14 | 28,0008.21 | 24,0007.03 | 38% | 2.08 | NC | 1 |
| TPLA0A0241EA*** (the pairing on screen) | Trane / Mitsubishi Electric | 9,2002.70 | 29,0008.50 | 24,0007.03 | 32% | 1.89 | NC | 1 |
| TPVA0A0241AA*** (the pairing on screen) | Trane / Mitsubishi Electric | 9,8002.87 | 28,0008.21 | 24,0007.03 | 35% | 1.73 | NC | 1 |
Sold as, and units with identical certified values
Brands listing this model number
Model number as listed
- TRUZA0241HA70** 12 pairings
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Dec 2, 2025
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read