YH2F42TB21
YH2F42TB21 is in the certified data.
Its certified full-speed heating output at 5°F is 18,400–22,600 Btu/h5.39–6.62 kW, 46–57% of its 47°F rating (tests at different compressor speeds), depending on the pairing.
York · central heat pump
YH2F42TB21 is in the certified data as of Sep 19, 2026.
- 42,000 Btu (3.5-ton)
- Central
- Two-stage
- US and Canada
Certified heating and cooling
Heating at 47°F
38,50011.28NR
No 47°F rating for this pairing.
25,2007.39NR at 17°F
20,8006.10NR at 5°F
Btu/hkW, certified
2.28NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 38,500 Btu/h11.28 kW of heat at 47°F, 25,200 Btu/h7.39 kW at 17°F, and 20,800 Btu/h6.10 kW at 5°F, 54% of its 47°F rating. It delivers 40,500 Btu/h11.87 kW of cooling at 95°F. At 5°F that is 12,200 Btu/h3.58 kW short of the example heating load of 33,000 Btu/h9.67 kW; at 95°F it is 23,500 Btu/h6.89 kW above the example cooling load of 17,000 Btu/h4.98 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at high stage; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 3.5-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 1,400 sq ft where winters reach 5°F: heating runs from 33,000 Btu/h9.67 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 17,000 Btu/h4.98 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 212474960 · listed by York · certified Jul 7, 2026 · 9 pairings share these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Fone compressor speed | 20,8006.10 kW | −37% | 2.28 | |
| 17°Fone compressor speed | 25,2007.39 kW | −19% | NR | |
| 47°Fone compressor speed | 38,50011.28 kW | −13% | NR | |
| 95°Fcooling, full load | 40,50011.87 kW | — | NR |
EER2 12.0 in that test. SEER2 16.0 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 2.67kW
- Electrical input in the 95°F cooling test
- 3.38kW
- Seasonal average heating COP
- 2.37
These exclude backup resistance heat.
How it compares with other 42,000 Btu heat pumps
3.5-ton central models
- This pairing at 5°F
- 20,800 Btu/h6.10 kWNR
- This unit at 5°F median across its pairings
- 20,800 Btu/h6.10 kW
- Median of 3.5-ton central models at 5°F
- 33,000 Btu/h9.67 kW
- Models in this group
- 222
This unit is above 36% of them, at number 143 of 222 by heat at 5°F. The middle half of the group runs 20,000 to 40,000 Btu/h.
Closest models by heat at 5°F
- J5HP5048A1000AAOXBOX · 21,400 Btu/h
- MOVA-48HN10-M152LMidea · 21,400 Btu/h
- RHP15042B21Evcon and Guardian · 20,800 Btu/h
- FRP15AZ42AJ2NFriedrich · 20,400 Btu/h
- LRP15HPK48VPLennox · 20,400 Btu/h
- RP15AZ42AJ2NRheem and Ruud · 20,400 Btu/h
Every 42,000 Btu (3.5-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for YH2F42TB21
449 pairings · 449 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F high stage | 38,500 Btu/h11.28 kWNR | 37,400–41,000 Btu/h10.96–12.02 kW |
| Heat output at 17°F full speed | 25,200 Btu/h7.39 kWNR | 24,200–26,600 Btu/h7.09–7.80 kW |
| Heat output at 5°F full speed | 20,800 Btu/h6.10 kWNR | 18,400–22,600 Btu/h5.39–6.62 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 54%NR | |
| COP at 5°F full speed | 2.28NR | 1.98–2.42 |
| HSPF2 Region IV | 8.1NR | 7.8–8.1 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 40,500 Btu/h11.87 kWNR | 39,500–42,000 Btu/h11.58–12.31 kW |
| EER2 at 95°F | 12.0NR | 11.7–12.0 |
| SEER2 cooling season | 16.0NR | 15.2–16.0 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-410A | |
| Compressor | Two-stage | |
| Indoor unit | XAFD60GXXN1+TXV | 78 indoor units |
| Furnace | Y81E080C16SMPS1 | 94 furnaces |
| Cold-climate designation EPA's designation, as published | NC | NC |
| ENERGY STAR Most Efficient EPA's designation, as published | No | On no pairings |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | YH2F42TB21 | |
Pairings, by indoor-unit class
78 indoor units · 449 certified pairings
One row per indoor unit certified with this outdoor unit.
Furnace paired · 10 indoor units
-
XAHC48FBCN1 (the pairing on screen) brand not stated 20,200 Btu/h5.92 kWat 5°F, full speed
-
XAFC48FBCN1 (the pairing on screen) brand not stated 19,700 Btu/h5.77 kWat 5°F, full speed
-
XAHD48FBCN1 (the pairing on screen) brand not stated 20,400 Btu/h5.98 kWat 5°F, full speed
-
XAFD48FBCN1 (the pairing on screen) brand not stated 19,800 Btu/h5.80 kWat 5°F, full speed
-
XAFC48FXXN1+TXV (the pairing on screen) brand not stated 19,850 Btu/h5.82 kWat 5°F, full speed
-
XAFC60GBCN1 (the pairing on screen) brand not stated 21,200 Btu/h6.21 kWat 5°F, full speed
-
XAHC60GBCN1 (the pairing on screen) brand not stated 22,000 Btu/h6.45 kWat 5°F, full speed
-
XAFD60GBCN1 (the pairing on screen) brand not stated 21,000 Btu/h6.15 kWat 5°F, full speed
-
XAFD60GXXN1+TXV (the pairing on screen) brand not stated 21,000 Btu/h6.15 kWat 5°F, full speed
-
XAHD60GBCN1 (the pairing on screen) brand not stated 22,000 Btu/h6.45 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · high stage | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| XAHC48FBCN1 (the pairing on screen) | — | 20,2005.92 | 40,00011.72 | 40,00011.72 | 51% | 2.12 | NC | 79 |
| XAFC48FBCN1 (the pairing on screen) | — | 19,7005.77 | 40,00011.72 | 40,50011.87 | 49% | 2.04 | NC | 56 |
| XAHD48FBCN1 (the pairing on screen) | — | 20,4005.98 | 40,00011.72 | 40,50011.87 | 51% | 2.13 | NC | 54 |
| XAFD48FBCN1 (the pairing on screen) | — | 19,8005.80 | 40,00011.72 | 40,50011.87 | 50% | 2.04 | NC | 53 |
| XAFC48FXXN1+TXV (the pairing on screen) | — | 19,8505.82 | 40,00011.72 | 40,50011.87 | 50% | 2.06 | NC | 44 |
| XAFC60GBCN1 (the pairing on screen) | — | 21,2006.21 | 38,50011.28 | 40,50011.87 | 55% | 2.26 | NC | 21 |
| XAHC60GBCN1 (the pairing on screen) | — | 22,0006.45 | 40,00011.72 | 41,00012.02 | 55% | 2.34 | NC | 20 |
| XAFD60GBCN1 (the pairing on screen) | — | 21,0006.15 | 38,50011.28 | 40,50011.87 | 55% | 2.28 | NC | 19 |
| XAFD60GXXN1+TXV (the pairing on screen) | — | 21,0006.15 | 38,50011.28 | 40,50011.87 | 55% | 2.28 | NC | 18 |
| XAHD60GBCN1 (the pairing on screen) | — | 22,0006.45 | 40,00011.72 | 41,00012.02 | 55% | 2.34 | NC | 17 |
Sold as, and units with identical certified values
Variants of the same model number
2 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
1 of 2 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Jul 7, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read