YH536E2S11
YH536E2S11 is in the certified data.
Its certified full-speed heating output at 5°F is 17,000–18,400 Btu/h4.98–5.39 kW, 53–59% of its 47°F rating (tests at different compressor speeds), depending on the pairing.
York · central heat pump
YH536E2S11 is in the certified data as of Sep 19, 2026. YH536E2S11 changed its certified HSPF2 on 5 pairings from 7.8 to 8.1 in the certified data between March 2025 and May 2025.
- 36,000 Btu (3-ton)
- Central
- Two-stage
- US and Canada
Certified heating and cooling
Heating at 47°F
32,0009.38NR
No 47°F rating for this pairing.
21,0006.15NR at 17°F
17,6005.16NR at 5°F
Btu/hkW, certified
2.00NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 32,000 Btu/h9.38 kW of heat at 47°F, 21,000 Btu/h6.15 kW at 17°F, and 17,600 Btu/h5.16 kW at 5°F, 55% of its 47°F rating. It delivers 33,800 Btu/h9.91 kW of cooling at 95°F. At 5°F that is 8,900 Btu/h2.61 kW short of the example heating load of 26,500 Btu/h7.77 kW; at 95°F it is 20,800 Btu/h6.10 kW above the example cooling load of 13,000 Btu/h3.81 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at high stage; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 3-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 1,100 sq ft where winters reach 5°F: heating runs from 26,500 Btu/h7.77 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 13,000 Btu/h3.81 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 214426908 · listed by York · certified Jul 17, 2026 · 8 pairings share these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Fone compressor speed | 17,6005.16 kW | −33% | 2.00 | |
| 17°Fone compressor speed | 21,0006.15 kW | −20% | NR | |
| 47°Fone compressor speed | 32,0009.38 kW | −9% | NR | |
| 95°Fcooling, full load | 33,8009.91 kW | — | NR |
EER2 11.0 in that test. SEER2 15.2 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 2.58kW
- Electrical input in the 95°F cooling test
- 3.07kW
- Seasonal average heating COP
- 2.37
These exclude backup resistance heat.
How it compares with other 36,000 Btu heat pumps
3-ton central models
- This pairing at 5°F
- 17,600 Btu/h5.16 kWNR
- This unit at 5°F median across its pairings
- 17,600 Btu/h5.16 kW
- Median of 3-ton central models at 5°F
- 26,400 Btu/h7.74 kW
- Models in this group
- 451
This unit is above 17% of them, at number 375 of 451 by heat at 5°F. The middle half of the group runs 18,650 to 32,000 Btu/h.
Closest models by heat at 5°F
- 5WCZ5036A1American Standard and Trane · 17,600 Btu/h
- GLZS5BA3610AGoodman · 17,600 Btu/h
- GSZH503610AGoodman · 17,600 Btu/h
- B5H6S36*K*AAA*Airquest, Arcoaire + 6 more · 17,500 Btu/h
- DRHP15A36AJ2ANDuraSTAR · 17,500 Btu/h
- FOP1536TJAZNAFujitsu · 17,500 Btu/h
Every 36,000 Btu (3-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for YH536E2S11
304 pairings · 304 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F high stage | 32,000 Btu/h9.38 kWNR | 30,600–32,800 Btu/h8.97–9.61 kW |
| Heat output at 17°F full speed | 21,000 Btu/h6.15 kWNR | 20,400–22,000 Btu/h5.98–6.45 kW |
| Heat output at 5°F full speed | 17,600 Btu/h5.16 kWNR | 17,000–18,400 Btu/h4.98–5.39 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 55%NR | |
| COP at 5°F full speed | 2.00NR | 2.00–2.44 |
| HSPF2 Region IV | 8.1NR | 7.8–8.1 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 33,800 Btu/h9.91 kWNR | 32,400–35,000 Btu/h9.50–10.26 kW |
| EER2 at 95°F | 11.0NR | 10.0–12.0 |
| SEER2 cooling season | 15.2NR | 15.2–16.0 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-454B | |
| Compressor | Two-stage | |
| Indoor unit | CTF48C5CFS1 | 97 indoor units |
| Furnace | Y81E080C20SMPS1 | 42 furnaces |
| Cold-climate designation EPA's designation, as published | NC | NC |
| ENERGY STAR Most Efficient EPA's designation, as published | No | On some pairings |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | YH536E2S11 | |
Pairings, by indoor-unit class
97 indoor units · 304 certified pairings
One row per indoor unit certified with this outdoor unit.
Furnace paired · 10 indoor units
-
CTM48C5CFS1 (the pairing on screen) brand not stated 17,800 Btu/h5.22 kWat 5°F, full speed
-
CTF48C5CFS1 (the pairing on screen) brand not stated 17,500 Btu/h5.13 kWat 5°F, full speed
-
CTU48C5XFS1+TXV (the pairing on screen) brand not stated 17,500 Btu/h5.13 kWat 5°F, full speed
-
CTM48C5CFS2 (the pairing on screen) brand not stated 17,900 Btu/h5.25 kWat 5°F, full speed
-
CTF48C5CFS2 (the pairing on screen) brand not stated 17,700 Btu/h5.19 kWat 5°F, full speed
-
CTU48C5XFS2+TXV (the pairing on screen) brand not stated 17,700 Btu/h5.19 kWat 5°F, full speed
-
CTM36C5CDS1 (the pairing on screen) brand not stated 17,800 Btu/h5.22 kWat 5°F, full speed
-
CTM36C5CDS2 (the pairing on screen) brand not stated 17,800 Btu/h5.22 kWat 5°F, full speed
-
CTF36C5CDS1 (the pairing on screen) brand not stated 17,800 Btu/h5.22 kWat 5°F, full speed
-
CTF36C5CDS2 (the pairing on screen) brand not stated 17,800 Btu/h5.22 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · high stage | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| CTM48C5CFS1 (the pairing on screen) | — | 17,8005.22 | 31,2009.14 | 34,0009.96 | 56% | 2.00 | NC | 37 |
| CTF48C5CFS1 (the pairing on screen) | — | 17,5005.13 | 31,4009.20 | 33,5009.82 | 55% | 2.00 | NC | 30 |
| CTU48C5XFS1+TXV (the pairing on screen) | — | 17,5005.13 | 31,4009.20 | 33,6009.85 | 55% | 2.00 | NC | 29 |
| CTM48C5CFS2 (the pairing on screen) | — | 17,9005.25 | 31,2009.14 | 34,20010.02 | 57% | 2.38 | NC | 25 |
| CTF48C5CFS2 (the pairing on screen) | — | 17,7005.19 | 31,8009.32 | 33,8009.91 | 55% | 2.00 | NC | 19 |
| CTU48C5XFS2+TXV (the pairing on screen) | — | 17,7005.19 | 31,8009.32 | 33,8009.91 | 55% | 2.00 | NC | 19 |
| CTM36C5CDS1 (the pairing on screen) | — | 17,8005.22 | 30,8009.03 | 32,6009.55 | 57% | 2.40 | NC | 15 |
| CTM36C5CDS2 (the pairing on screen) | — | 17,8005.22 | 30,8009.03 | 32,6009.55 | 57% | 2.40 | NC | 15 |
| CTF36C5CDS1 (the pairing on screen) | — | 17,8005.22 | 32,0009.38 | 32,7009.58 | 55% | 2.00 | NC | 14 |
| CTF36C5CDS2 (the pairing on screen) | — | 17,8005.22 | 32,0009.38 | 32,7009.58 | 55% | 2.00 | NC | 14 |
Sold as, and units with identical certified values
Variants of the same model number
2 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
1 of 2 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
Product history
- YH536E2S11 changed its certified HSPF2 on 5 pairings from 7.8 to 8.1 in the certified data between March 2025 and May 2025.
- YH536E2S11 changed its certified EER2 on 13 pairings in the certified data between March 2025 and May 2025. The new figure is higher on 6 and lower on 7.
- YH536E2S11 changed its certified cooling capacity at 95°F on 17 pairings in the certified data between March 2025 and May 2025. The new figure is higher on 13 and lower on 4.
- YH536E2S11 changed its certified heat output at 5°F on 4 pairings in the certified data between March 2025 and May 2025. The new figure is higher on all 4.
- YH536E2S11 changed its certified heat output at 47°F on 20 pairings in the certified data between March 2025 and May 2025. The new figure is higher on 4 and lower on 16.
- YH536E2S11 changed its certified heat output at 17°F on 4 pairings in the certified data between March 2025 and May 2025. The new figure is higher on all 4.
- YH536E2S11 was in the certified data by September 2024.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Jul 17, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read