Heat Pump List

Tools

YH960E2C11

YH960E2C11 is in the certified data.

Its certified full-speed heating output at 5°F is 43,500–45,000 Btu/h, 76–95% of its 47°F rating (tests at different compressor speeds), depending on the pairing.

York · central heat pump

YH960E2C11 is in the certified data as of Oct 18, 2026.

205 certified pairings with 34 different figures. See all

Certified heating and cooling

Heating at 47°F

48,000

37,200 at 17°F

45,000 at 5°F

Btu/h, certified

1.98 COP at 5°F

Cooling at 95°F

47,000

Btu/h, certified

EER2 10.0 at 95°F

SEER2 20.0

Heating and cooling by outdoor temperature

Certified heating at 5, 17, and 47°F and cooling at 95°F for YH960E2C11, by outdoor temperature Heating: 45,000 Btu/h at 5°F, 37,200 Btu/h at 17°F, 48,000 Btu/h at 47°F. Cooling: 47,000 Btu/h at 95°F. The bars start at zero. Median of 4-ton central models: 36,400 Btu/h at 5°F, 35,000 Btu/h at 17°F, 48,000 Btu/h at 47°F, 48,000 Btu/h at 95°F. 0 20,000 40,000 60,000 Btu/h 45,000 5°F 37,200 17°F 48,000 47°F 47,000 95°F Outdoor temperature (°F)
  • Heating output
  • Cooling output
  • Median of 4-ton central models
  • Example heating load
  • Example cooling load
  • Frosting range, 17 to 45°F

This pairing delivers 48,000 Btu/h of heat at 47°F, 37,200 Btu/h at 17°F, and 45,000 Btu/h at 5°F, 94% of its 47°F rating. It delivers 47,000 Btu/h of cooling at 95°F. At 5°F that is 8,500 Btu/h above the example heating load of 36,500 Btu/h; at 95°F it is 29,000 Btu/h above the example cooling load of 18,000 Btu/h.

Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 4-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.

The dashed lines are example loads for a typical area of about 1,500 sq ft where winters reach 5°F: heating runs from 36,500 Btu/h at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 18,000 Btu/h at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.

Calculate heating and cooling for your house

AHRI certificate 218026731 · listed by York · certified Jul 23, 2026 · 29 pairings share these values

All rebate programs and their published thresholds

Certified output and power use

Certified output for the selected pairingThe four bars share one scale. The comparison is with the median of 4-ton central models. Heating tests run at 70°F indoors. The cooling test runs at 80°F indoors.
Outdoor temperature Certified outputBtu/h One scale vs class median COPat 5°F
5°Ffull speed 45,00013.19 kW +24% 1.98
17°Ffull speed 37,20010.90 kW +6% NR
47°Fnormal speed 48,00014.07 kW 0% NR
95°Fcooling, full load 47,00013.77 kW — NR

EER2 10.0 in that test. SEER2 20.0 over the modeled cooling season.

Power use at each temperature

Electrical input in the 5°F full-speed test
6.66kW
Electrical input in the 95°F cooling test
4.70kW
Seasonal average heating COP
2.49

These exclude backup resistance heat.

Updated Oct 18, 2026 · Methodology

How it compares with other 48,000 Btu heat pumps

4-ton central models

This pairing at 5°F
45,000 Btu/h
This unit at 5°F median across its pairings
45,000 Btu/h
Median of 4-ton central models at 5°F
36,400 Btu/h
Models in this group
408

This unit is above 73% of them, at number 110 of 408 by heat at 5°F. The middle half of the group runs 25,350 to 46,000 Btu/h.

This size class is defined by cooling capacity, so cooling is not compared here.

Closest models by heat at 5°F

Every 48,000 Btu (4-ton) unit, ranked by cooling efficiency, then heating efficiency

Certified values for YH960E2C11

205 pairings · 205 AHRI certificates

This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.

Certified values for YH960E2C11
This pairingAll pairings
Heating
Heat output at 47°F normal speed 48,000 Btu/h 46,500–59,000 Btu/h
Heat output at 17°F full speed 37,200 Btu/h 34,000–47,500 Btu/h
Heat output at 5°F full speed 45,000 Btu/h 43,500–45,000 Btu/h
Heat output below 5°F NR NR
Cold output 5°F output as a % of the 47°F rating 94%
COP at 5°F full speed 1.98 1.98–2.00
HSPF2 Region IV 8.5 8.5–9.0
Cooling
Cooling capacity at 95°F full-load test 47,000 Btu/h 47,000–56,000 Btu/h
EER2 at 95°F 10.0 9.0–12.0
SEER2 cooling season 20.0 19.0–22.0
Cooling at other temperatures NR NR
Equipment and listing
Refrigerant R-454B
Compressor Variable speed
Indoor unit CTF60C5CGS1+CC 41 indoor units
FurnaceTM9V100C16MP12 34 furnaces
Cold-climate designation EPA's designation, as published Yes On some pairings
ENERGY STAR Most Efficient EPA's designation, as published Yes On some pairings
Where it is sold US and Canada US and Canada
Model string as certified YH960E2C11

Pairings, by indoor-unit class

41 indoor units · 205 certified pairings

One row per indoor unit certified with this outdoor unit.

Furnace paired · 10 indoor units

  1. CTF60C5CGS1+CC (the pairing on screen) brand not stated 45,000 Btu/hat 5°F, full speed

    30 pairings, 30 with a furnace · 47°F 48,000 Btu/h · 95°F cooling 47,000 Btu/h · Cold output 94% · COP 2.00

  2. CTM60C5CGS1+CC brand not stated 45,000 Btu/hat 5°F, full speed

    30 pairings, 30 with a furnace · 47°F 48,000 Btu/h · 95°F cooling 47,000 Btu/h · Cold output 94% · COP 2.00

  3. CTM60C5CGS2+CC brand not stated 45,000 Btu/hat 5°F, full speed

    30 pairings, 30 with a furnace · 47°F 48,000 Btu/h · 95°F cooling 47,000 Btu/h · Cold output 94% · COP 2.00

  4. CTF60C5CGS2+CC brand not stated 45,000 Btu/hat 5°F, full speed

    20 pairings, 20 with a furnace · 47°F 48,000 Btu/h · 95°F cooling 47,000 Btu/h · Cold output 94% · COP 2.00

  5. CTF60C5CHS1+CC brand not stated 44,000 Btu/hat 5°F, full speed

    13 pairings, 13 with a furnace · 47°F 58,000 Btu/h · 95°F cooling 55,000 Btu/h · Cold output 76% · COP 2.00

  6. CTM60C5CHS1+CC brand not stated 44,000 Btu/hat 5°F, full speed

    13 pairings, 13 with a furnace · 47°F 58,000 Btu/h · 95°F cooling 55,000 Btu/h · Cold output 76% · COP 2.00

  7. CTF60C5CHS2+CC brand not stated 44,000 Btu/hat 5°F, full speed

    7 pairings, 7 with a furnace · 47°F 58,000 Btu/h · 95°F cooling 55,000 Btu/h · Cold output 76% · COP 2.00

  8. CTM60C5CHS2+CC brand not stated 44,000 Btu/hat 5°F, full speed

    7 pairings, 7 with a furnace · 47°F 58,000 Btu/h · 95°F cooling 55,000 Btu/h · Cold output 76% · COP 2.00

  9. CTF60D5CGS1+CC brand not stated 45,000 Btu/hat 5°F, full speed

    4 pairings, 4 with a furnace · 47°F 48,000 Btu/h · 95°F cooling 47,000 Btu/h · Cold output 94% · COP 2.00

  10. CTF60D5CGS2+CC brand not stated 45,000 Btu/hat 5°F, full speed

    4 pairings, 4 with a furnace · 47°F 48,000 Btu/h · 95°F cooling 47,000 Btu/h · Cold output 94% · COP 2.00

Indoor units in the furnace paired class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · normal speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
CTF60C5CGS1+CC (the pairing on screen) — 45,000 48,000 47,000 94% 2.00 Yes 30
CTM60C5CGS1+CC — 45,000 48,000 47,000 94% 2.00 Yes 30
CTM60C5CGS2+CC — 45,000 48,000 47,000 94% 2.00 Yes 30
CTF60C5CGS2+CC — 45,000 48,000 47,000 94% 2.00 Yes 20
CTF60C5CHS1+CC — 44,000 58,000 55,000 76% 2.00 Yes 13
CTM60C5CHS1+CC — 44,000 58,000 55,000 76% 2.00 Yes 13
CTF60C5CHS2+CC — 44,000 58,000 55,000 76% 2.00 Yes 7
CTM60C5CHS2+CC — 44,000 58,000 55,000 76% 2.00 Yes 7
CTF60D5CGS1+CC — 45,000 48,000 47,000 94% 2.00 Yes 4
CTF60D5CGS2+CC — 45,000 48,000 47,000 94% 2.00 Yes 4

The share is heat output at 5°F divided by the 47°F rating.

Showing 10 of 41 indoor units All 205 certified pairings

Sold as, and units with identical certified values

Brands listing this model number

Model number as listed

Variants of the same model number

2 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.

1 of 2 shown.

History and definitions

History

First certified record
Most recent certified record
Measurements reported
Jul 23, 2026
Status
In the certified data

Field definitions

COP
Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
HSPF2
Heating efficiency over a typical season. Higher uses less electricity.
SEER2
Cooling efficiency over a typical season. Higher uses less electricity.
EER2
Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
Cold output
Heat output at 5°F as a percentage of the 47°F rating.
% of rating at 17°F
Heat output at 17°F as a percentage of the 47°F rating.

NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read

Cite or print this page

Heat Pump List, “YH960E2C11 — certified heat output”. Certified figures dated , checked daily.
https://heatpumplist.com/model/yh960e2c11