YH960E2C11
YH960E2C11 is in the certified data.
Its certified full-speed heating output at 5°F is 43,500–45,000 Btu/h12.75–13.19 kW, 76–95% of its 47°F rating (tests at different compressor speeds), depending on the pairing.
York · central heat pump
YH960E2C11 is in the certified data as of Oct 18, 2026.
- 48,000 Btu (4-ton)
- Central
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
48,00014.07NR
No 47°F rating for this pairing.
37,20010.90NR at 17°F
45,00013.19NR at 5°F
Btu/hkW, certified
1.98NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 48,000 Btu/h14.07 kW of heat at 47°F, 37,200 Btu/h10.90 kW at 17°F, and 45,000 Btu/h13.19 kW at 5°F, 94% of its 47°F rating. It delivers 47,000 Btu/h13.77 kW of cooling at 95°F. At 5°F that is 8,500 Btu/h2.49 kW above the example heating load of 36,500 Btu/h10.70 kW; at 95°F it is 29,000 Btu/h8.50 kW above the example cooling load of 18,000 Btu/h5.28 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 4-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 1,500 sq ft where winters reach 5°F: heating runs from 36,500 Btu/h10.70 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 18,000 Btu/h5.28 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 218026731 · listed by York · certified Jul 23, 2026 · 29 pairings share these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 45,00013.19 kW | +24% | 1.98 | |
| 17°Ffull speed | 37,20010.90 kW | +6% | NR | |
| 47°Fnormal speed | 48,00014.07 kW | 0% | NR | |
| 95°Fcooling, full load | 47,00013.77 kW | — | NR |
EER2 10.0 in that test. SEER2 20.0 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 6.66kW
- Electrical input in the 95°F cooling test
- 4.70kW
- Seasonal average heating COP
- 2.49
These exclude backup resistance heat.
How it compares with other 48,000 Btu heat pumps
4-ton central models
- This pairing at 5°F
- 45,000 Btu/h13.19 kWNR
- This unit at 5°F median across its pairings
- 45,000 Btu/h13.19 kW
- Median of 4-ton central models at 5°F
- 36,400 Btu/h10.67 kW
- Models in this group
- 408
This unit is above 73% of them, at number 110 of 408 by heat at 5°F. The middle half of the group runs 25,350 to 46,000 Btu/h.
Closest models by heat at 5°F
- MDPH180484MRCOOL · 46,000 Btu/h
- ML48HP230LMNTH-OMainline · 46,000 Btu/h
- MOE30U-48HFN1-M-[X]MDV · 46,000 Btu/h
- VUH48-VA6BA(O)Samyou and Vino · 44,500 Btu/h
- GZV9SA4810AGoodman · 44,000 Btu/h
- 5HCL5060B1American Standard and Trane · 43,000 Btu/h
Every 48,000 Btu (4-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for YH960E2C11
205 pairings · 205 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 48,000 Btu/h14.07 kWNR | 46,500–59,000 Btu/h13.63–17.29 kW |
| Heat output at 17°F full speed | 37,200 Btu/h10.90 kWNR | 34,000–47,500 Btu/h9.96–13.92 kW |
| Heat output at 5°F full speed | 45,000 Btu/h13.19 kWNR | 43,500–45,000 Btu/h12.75–13.19 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 94%NR | |
| COP at 5°F full speed | 1.98NR | 1.98–2.00 |
| HSPF2 Region IV | 8.5NR | 8.5–9.0 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 47,000 Btu/h13.77 kWNR | 47,000–56,000 Btu/h13.77–16.41 kW |
| EER2 at 95°F | 10.0NR | 9.0–12.0 |
| SEER2 cooling season | 20.0NR | 19.0–22.0 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-454B | |
| Compressor | Variable speed | |
| Indoor unit | CTF60C5CGS1+CC | 41 indoor units |
| Furnace | TM9V100C16MP12 | 34 furnaces |
| Cold-climate designation EPA's designation, as published | Yes | On some pairings |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On some pairings |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | YH960E2C11 | |
Pairings, by indoor-unit class
41 indoor units · 205 certified pairings
One row per indoor unit certified with this outdoor unit.
Furnace paired · 10 indoor units
-
CTF60C5CGS1+CC (the pairing on screen) brand not stated 45,000 Btu/h13.19 kWat 5°F, full speed
-
CTM60C5CGS1+CC (the pairing on screen) brand not stated 45,000 Btu/h13.19 kWat 5°F, full speed
-
CTM60C5CGS2+CC (the pairing on screen) brand not stated 45,000 Btu/h13.19 kWat 5°F, full speed
-
CTF60C5CGS2+CC (the pairing on screen) brand not stated 45,000 Btu/h13.19 kWat 5°F, full speed
-
CTF60C5CHS1+CC (the pairing on screen) brand not stated 44,000 Btu/h12.90 kWat 5°F, full speed
-
CTM60C5CHS1+CC (the pairing on screen) brand not stated 44,000 Btu/h12.90 kWat 5°F, full speed
-
CTF60C5CHS2+CC (the pairing on screen) brand not stated 44,000 Btu/h12.90 kWat 5°F, full speed
-
CTM60C5CHS2+CC (the pairing on screen) brand not stated 44,000 Btu/h12.90 kWat 5°F, full speed
-
CTF60D5CGS1+CC (the pairing on screen) brand not stated 45,000 Btu/h13.19 kWat 5°F, full speed
-
CTF60D5CGS2+CC (the pairing on screen) brand not stated 45,000 Btu/h13.19 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| CTF60C5CGS1+CC (the pairing on screen) | — | 45,00013.19 | 48,00014.07 | 47,00013.77 | 94% | 2.00 | Yes | 30 |
| CTM60C5CGS1+CC (the pairing on screen) | — | 45,00013.19 | 48,00014.07 | 47,00013.77 | 94% | 2.00 | Yes | 30 |
| CTM60C5CGS2+CC (the pairing on screen) | — | 45,00013.19 | 48,00014.07 | 47,00013.77 | 94% | 2.00 | Yes | 30 |
| CTF60C5CGS2+CC (the pairing on screen) | — | 45,00013.19 | 48,00014.07 | 47,00013.77 | 94% | 2.00 | Yes | 20 |
| CTF60C5CHS1+CC (the pairing on screen) | — | 44,00012.90 | 58,00017.00 | 55,00016.12 | 76% | 2.00 | Yes | 13 |
| CTM60C5CHS1+CC (the pairing on screen) | — | 44,00012.90 | 58,00017.00 | 55,00016.12 | 76% | 2.00 | Yes | 13 |
| CTF60C5CHS2+CC (the pairing on screen) | — | 44,00012.90 | 58,00017.00 | 55,00016.12 | 76% | 2.00 | Yes | 7 |
| CTM60C5CHS2+CC (the pairing on screen) | — | 44,00012.90 | 58,00017.00 | 55,00016.12 | 76% | 2.00 | Yes | 7 |
| CTF60D5CGS1+CC (the pairing on screen) | — | 45,00013.19 | 48,00014.07 | 47,00013.77 | 94% | 2.00 | Yes | 4 |
| CTF60D5CGS2+CC (the pairing on screen) | — | 45,00013.19 | 48,00014.07 | 47,00013.77 | 94% | 2.00 | Yes | 4 |
Sold as, and units with identical certified values
Variants of the same model number
2 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
1 of 2 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Jul 23, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read