5HCL5060B1
5HCL5060B1 is in the certified data.
Its certified full-speed heating output at 5°F is 40,500–48,000 Btu/h11.87–14.07 kW, 80–98% of its 47°F rating (tests at different compressor speeds), depending on the pairing.
American Standard and Trane · central heat pump
5HCL5060B1 is in the certified data as of Sep 19, 2026. 5HCL5060B1 changed its certified HSPF2 on 2 pairings from 8.5 to 8.8 in the certified data between August 2025 and September 2026.
- 48,000 Btu (4-ton)
- Central
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
54,00015.83NR
No 47°F rating for this pairing.
44,00012.90NR at 17°F
43,00012.60NR at 5°F
Btu/hkW, certified
1.75NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 54,000 Btu/h15.83 kW of heat at 47°F, 44,000 Btu/h12.90 kW at 17°F, and 43,000 Btu/h12.60 kW at 5°F, 80% of its 47°F rating. It delivers 54,000 Btu/h15.83 kW of cooling at 95°F. At 5°F that is 6,500 Btu/h1.90 kW above the example heating load of 36,500 Btu/h10.70 kW; at 95°F it is 36,000 Btu/h10.55 kW above the example cooling load of 18,000 Btu/h5.28 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 4-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 1,500 sq ft where winters reach 5°F: heating runs from 36,500 Btu/h10.70 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 18,000 Btu/h5.28 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 217500301 · listed by Trane · certified Jun 9, 2026 · 2 pairings share these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 43,00012.60 kW | +18% | 1.75 | |
| 17°Ffull speed | 44,00012.90 kW | +26% | NR | |
| 47°Fnormal speed | 54,00015.83 kW | +13% | NR | |
| 95°Fcooling, full load | 54,00015.83 kW | — | NR |
EER2 10.5 in that test. SEER2 18.5 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 7.20kW
- Electrical input in the 95°F cooling test
- 5.14kW
- Seasonal average heating COP
- 2.78
These exclude backup resistance heat.
How it compares with other 48,000 Btu heat pumps
4-ton central models
- This pairing at 5°F
- 43,000 Btu/h12.60 kWNR
- This unit at 5°F median across its pairings
- 43,000 Btu/h12.60 kW
- Median of 4-ton central models at 5°F
- 36,400 Btu/h10.67 kW
- Models in this group
- 408
This unit is above 71% of them, at number 120 of 408 by heat at 5°F. The middle half of the group runs 25,350 to 46,000 Btu/h.
Closest models by heat at 5°F
- YH960E2C11York · 45,000 Btu/h
- VUH48-VA6BA(O)Samyou and Vino · 44,500 Btu/h
- GZV9SA4810AGoodman · 44,000 Btu/h
- KUSXA482ALG · 43,000 Btu/h
- AC048BXUPCHSamsung · 42,000 Btu/h
- CH-PQ48-230VOCooper&Hunter · 42,000 Btu/h
Every 48,000 Btu (4-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for 5HCL5060B1
8 pairings · 8 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 54,000 Btu/h15.83 kWNR | 48,000–54,000 Btu/h14.07–15.83 kW |
| Heat output at 17°F full speed | 44,000 Btu/h12.90 kWNR | 34,000–44,000 Btu/h9.96–12.90 kW |
| Heat output at 5°F full speed | 43,000 Btu/h12.60 kWNR | 40,500–48,000 Btu/h11.87–14.07 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 80%NR | |
| COP at 5°F full speed | 1.75NR | 1.75–1.85 |
| HSPF2 Region IV | 9.5NR | 8.5–9.5 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 54,000 Btu/h15.83 kWNR | 47,000–54,000 Btu/h13.77–15.83 kW |
| EER2 at 95°F | 10.5NR | 10.0–11.5 |
| SEER2 cooling season | 18.5NR | 16.0–19.0 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-454B | |
| Compressor | Variable speed | |
| Indoor unit | 5TDM5D07AC51 | 4 indoor units |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On every pairing |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | 5HCL5060B1 | |
Pairings, by indoor-unit class
4 indoor units · 8 certified pairings
One row per indoor unit certified with this outdoor unit.
Air handler · 4 indoor units
-
5DXCD008AC3 (the pairing on screen) brand not stated 47,000 Btu/h13.77 kWat 5°F, full speed
-
5DXCD010AC3 (the pairing on screen) brand not stated 48,000 Btu/h14.07 kWat 5°F, full speed
-
5TDM5D06AC41 (the pairing on screen) brand not stated 40,500 Btu/h11.87 kWat 5°F, full speed
-
5TDM5D07AC51 (the pairing on screen) brand not stated 43,000 Btu/h12.60 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| 5DXCD008AC3 (the pairing on screen) | — | 47,00013.77 | 48,00014.07 | 47,00013.77 | 98% | 1.85 | Yes | 2 |
| 5DXCD010AC3 (the pairing on screen) | — | 48,00014.07 | 54,00015.83 | 52,00015.24 | 89% | 1.80 | Yes | 2 |
| 5TDM5D06AC41 (the pairing on screen) | — | 40,50011.87 | 48,00014.07 | 48,00014.07 | 84% | 1.80 | Yes | 2 |
| 5TDM5D07AC51 (the pairing on screen) | — | 43,00012.60 | 54,00015.83 | 54,00015.83 | 80% | 1.75 | Yes | 2 |
Sold as, and units with identical certified values
Brands listing this model number
Other brands that list these model numbers
Model number as listed
- 5HCL5060B1 8 pairings
Variants of the same model number
4 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
3 of 4 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
Product history
- 5HCL5060B1 changed its certified HSPF2 on 2 pairings from 8.5 to 8.8 in the certified data between August 2025 and September 2026.
- 5HCL5060B1 changed its certified EER2 on 2 pairings from 9.8 to 10.0 in the certified data between August 2025 and September 2026.
- 5HCL5060B1 changed its certified heat output at 5°F on 4 pairings in the certified data between August 2025 and September 2026. The new figure is higher on all 4.
- 5HCL5060B1 changed its certified heat output at 17°F on 4 pairings in the certified data between August 2025 and September 2026. The new figure is higher on all 4.
- 5HCL5060B1 first appeared in the certified data between May 2025 and June 2025.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Jun 9, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read