KUSXA482A
KUSXA482A is in the certified data.
Its certified full-speed heating output at 5°F is 43,000–46,000 Btu/h12.60–13.48 kW, 86–92% of its 47°F rating (tests at different compressor speeds), depending on the pairing.
LG · central heat pump
KUSXA482A is in the certified data as of Sep 19, 2026.
- 48,000 Btu (4-ton)
- Central
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
50,00014.65NR
No 47°F rating for this pairing.
32,6009.55NR at 17°F
43,00012.60NR at 5°F
Btu/hkW, certified
1.90NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 50,000 Btu/h14.65 kW of heat at 47°F, 32,600 Btu/h9.55 kW at 17°F, and 43,000 Btu/h12.60 kW at 5°F, 86% of its 47°F rating. It delivers 45,500 Btu/h13.33 kW of cooling at 95°F. At 5°F that is 6,500 Btu/h1.90 kW above the example heating load of 36,500 Btu/h10.70 kW; at 95°F it is 27,500 Btu/h8.06 kW above the example cooling load of 18,000 Btu/h5.28 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 4-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 1,500 sq ft where winters reach 5°F: heating runs from 36,500 Btu/h10.70 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 18,000 Btu/h5.28 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 216445261 · listed by LG · certified Mar 31, 2025 · 1 pairing carries these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 43,00012.60 kW | +18% | 1.90 | |
| 17°Ffull speed | 32,6009.55 kW | −7% | NR | |
| 47°Fnormal speed | 50,00014.65 kW | +4% | NR | |
| 95°Fcooling, full load | 45,50013.33 kW | — | NR |
EER2 11.7 in that test. SEER2 15.9 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 6.63kW
- Electrical input in the 95°F cooling test
- 3.89kW
- Seasonal average heating COP
- 2.61
These exclude backup resistance heat.
How it compares with other 48,000 Btu heat pumps
4-ton central models
- This pairing at 5°F
- 43,000 Btu/h12.60 kWNR
- This unit at 5°F median across its pairings
- 43,000 Btu/h12.60 kW
- Median of 4-ton central models at 5°F
- 36,400 Btu/h10.67 kW
- Models in this group
- 408
This unit is above 71% of them, at number 120 of 408 by heat at 5°F. The middle half of the group runs 25,350 to 46,000 Btu/h.
Closest models by heat at 5°F
- VUH48-VA6BA(O)Samyou and Vino · 44,500 Btu/h
- GZV9SA4810AGoodman · 44,000 Btu/h
- 5HCL5060B1American Standard and Trane · 43,000 Btu/h
- AC048BXUPCHSamsung · 42,000 Btu/h
- CH-PQ48-230VOCooper&Hunter · 42,000 Btu/h
- CU-HM48BAHUPanasonic · 42,000 Btu/h
Every 48,000 Btu (4-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for KUSXA482A
6 pairings · 6 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 50,000 Btu/h14.65 kWNR | 48,000–50,000 Btu/h14.07–14.65 kW |
| Heat output at 17°F full speed | 32,600 Btu/h9.55 kWNR | 30,400–33,000 Btu/h8.91–9.67 kW |
| Heat output at 5°F full speed | 43,000 Btu/h12.60 kWNR | 43,000–46,000 Btu/h12.60–13.48 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 86%NR | |
| COP at 5°F full speed | 1.90NR | 1.90–2.00 |
| HSPF2 Region IV | 8.9NR | 8.9–9.6 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 45,500 Btu/h13.33 kWNR | 45,500–48,000 Btu/h13.33–14.07 kW |
| EER2 at 95°F | 11.7NR | 11.0–12.3 |
| SEER2 cooling season | 15.9NR | 15.9–19.0 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-32 | |
| Compressor | Variable speed | |
| Indoor unit | LKMMA48C1 | 3 indoor units |
| Furnace | No furnace | 2 furnaces |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | No | On some pairings |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | KUSXA482A | |
Pairings, by indoor-unit class
3 indoor units · 6 certified pairings
One row per indoor unit certified with this outdoor unit.
Air handler · 3 indoor units
-
KNSLB481A (the pairing on screen) LG 46,000 Btu/h13.48 kWat 5°F, full speed
-
LKMMA48C1 (the pairing on screen) brand not stated 43,500 Btu/h12.75 kWat 5°F, full speed
-
LKMMA48D1 (the pairing on screen) brand not stated 43,000 Btu/h12.60 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| KNSLB481A (the pairing on screen) | LG | 46,00013.48 | 50,00014.65 | 46,00013.48 | 92% | 2.00 | Yes | 2 |
| LKMMA48C1 (the pairing on screen) | — | 43,50012.75 | 49,00014.36 | 45,75013.41 | 89% | 1.90 | Yes | 2 |
| LKMMA48D1 (the pairing on screen) | — | 43,00012.60 | 50,00014.65 | 46,75013.70 | 86% | 1.95 | Yes | 2 |
Sold as, and units with identical certified values
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
Product history
- KUSXA482A first appeared in the certified data between September 2024 and November 2024.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Mar 31, 2025
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read