YOHA2-36CB
YOHA2-36CB is in the certified data.
Its certified full-speed heating output at 5°F is 17,200–25,200 Btu/h5.04–7.39 kW, 60–82% of its 47°F rating (tests at different compressor speeds), depending on the pairing.
Yiso · central heat pump
YOHA2-36CB is in the certified data as of Sep 19, 2026.
- 30,000 Btu (2.5-ton)
- Central
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
34,60010.14NR
No 47°F rating for this pairing.
26,6007.80NR at 17°F
22,8006.68NR at 5°F
Btu/hkW, certified
1.95NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 34,600 Btu/h10.14 kW of heat at 47°F, 26,600 Btu/h7.80 kW at 17°F, and 22,800 Btu/h6.68 kW at 5°F, 66% of its 47°F rating. It delivers 33,000 Btu/h9.67 kW of cooling at 95°F. At 5°F that is 300 Btu/h0.09 kW above the example heating load of 22,500 Btu/h6.59 kW; at 95°F it is 21,500 Btu/h6.30 kW above the example cooling load of 11,500 Btu/h3.37 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 2.5-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 950 sq ft where winters reach 5°F: heating runs from 22,500 Btu/h6.59 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 11,500 Btu/h3.37 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 217563403 · listed by YISO · certified Jul 9, 2025 · 4 pairings share these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 22,8006.68 kW | +2% | 1.95 | |
| 17°Ffull speed | 26,6007.80 kW | +29% | NR | |
| 47°Fnormal speed | 34,60010.14 kW | +15% | NR | |
| 95°Fcooling, full load | 33,0009.67 kW | — | NR |
EER2 11.0 in that test. SEER2 18.0 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 3.43kW
- Electrical input in the 95°F cooling test
- 3.00kW
- Seasonal average heating COP
- 2.55
These exclude backup resistance heat.
How it compares with other 30,000 Btu heat pumps
2.5-ton central models
- This pairing at 5°F
- 22,800 Btu/h6.68 kWNR
- This unit at 5°F median across its pairings
- 22,800 Btu/h6.68 kW
- Median of 2.5-ton central models at 5°F
- 22,400 Btu/h6.56 kW
- Models in this group
- 288
This unit is above 51% of them, at number 142 of 288 by heat at 5°F. The middle half of the group runs 14,250 to 30,000 Btu/h.
Closest models by heat at 5°F
- DLCURAH30ABKAirquest, Arcoaire + 12 more · 24,000 Btu/h
- UHO30-NB-QMitsutomo · 24,000 Btu/h
- WFPU18Z363CFriedrich · 23,200 Btu/h
- YOHA3-36DDYiso · 22,400 Btu/h
- MOX430-30HFN8-M3MDV · 22,000 Btu/h
- 3036SPV0-HP-X-DMulti MFG · 21,500 Btu/h
Every 30,000 Btu (2.5-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for YOHA2-36CB
54 pairings · 54 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 34,600 Btu/h10.14 kWNR | 23,000–36,000 Btu/h6.74–10.55 kW |
| Heat output at 17°F full speed | 26,600 Btu/h7.80 kWNR | 18,200–28,800 Btu/h5.33–8.44 kW |
| Heat output at 5°F full speed | 22,800 Btu/h6.68 kWNR | 17,200–25,200 Btu/h5.04–7.39 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 66%NR | |
| COP at 5°F full speed | 1.95NR | 1.80–2.10 |
| HSPF2 Region IV | 8.7NR | 8.3–10.0 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 33,000 Btu/h9.67 kWNR | 22,600–34,200 Btu/h6.62–10.02 kW |
| EER2 at 95°F | 11.0NR | 10.2–13.0 |
| SEER2 cooling season | 18.0NR | 15.2–20.0 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-454B | |
| Compressor | Variable speed | |
| Indoor unit | YLAN4-4248CB | 12 indoor units |
| Furnace | MGH96M080C4A | 19 furnaces |
| Cold-climate designation EPA's designation, as published | NC | On some pairings |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On some pairings |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | YOHA2-36CB | |
Pairings, by indoor-unit class
12 indoor units · 54 certified pairings
One row per indoor unit certified with this outdoor unit.
Furnace paired · 2 indoor units
-
YLAN4-4248CB (the pairing on screen) brand not stated 22,800 Btu/h6.68 kWat 5°F, full speed
-
YLCN4-4248CE (the pairing on screen) brand not stated 24,000 Btu/h7.03 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| YLAN4-4248CB (the pairing on screen) | — | 22,8006.68 | 34,60010.14 | 33,0009.67 | 66% | 1.95 | NC | 8 |
| YLCN4-4248CE (the pairing on screen) | — | 24,0007.03 | 34,20010.02 | 33,0009.67 | 70% | 1.95 | Yes | 2 |
Air handler · 8 indoor units
-
YLAN4-2430BB (the pairing on screen) brand not stated 19,400 Btu/h5.69 kWat 5°F, full speed
-
YLAN4-3036BB (the pairing on screen) brand not stated 24,400 Btu/h7.15 kWat 5°F, full speed
-
YLCN4-2430BE (the pairing on screen) brand not stated 19,400 Btu/h5.69 kWat 5°F, full speed
-
YLCN4-3036BE (the pairing on screen) brand not stated 24,400 Btu/h7.15 kWat 5°F, full speed
-
YLAN4-2430AB (the pairing on screen) brand not stated 19,200 Btu/h5.63 kWat 5°F, full speed
-
YAHA2-24CB (the pairing on screen) brand not stated 19,600 Btu/h5.74 kWat 5°F, full speed
-
YAHA2-36CB (the pairing on screen) brand not stated 25,200 Btu/h7.39 kWat 5°F, full speed
-
YAHA3-24DE (the pairing on screen) brand not stated 19,600 Btu/h5.74 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| YLAN4-2430BB (the pairing on screen) | — | 19,4005.69 | 24,0007.03 | 24,0007.03 | 81% | 2.10 | Yes | 11 |
| YLAN4-3036BB (the pairing on screen) | — | 24,4007.15 | 34,60010.14 | 33,0009.67 | 71% | 1.95 | Yes | 11 |
| YLCN4-2430BE (the pairing on screen) | — | 19,4005.69 | 24,0007.03 | 24,0007.03 | 81% | 2.05 | Yes | 6 |
| YLCN4-3036BE (the pairing on screen) | — | 24,4007.15 | 34,60010.14 | 33,0009.67 | 71% | 1.95 | Yes | 6 |
| YLAN4-2430AB (the pairing on screen) | — | 19,2005.63 | 24,0007.03 | 23,8006.98 | 80% | 2.00 | Yes | 5 |
| YAHA2-24CB (the pairing on screen) | — | 19,6005.74 | 24,0007.03 | 24,0007.03 | 82% | 2.10 | Yes | 1 |
| YAHA2-36CB (the pairing on screen) | — | 25,2007.39 | 36,00010.55 | 34,20010.02 | 70% | 2.00 | Yes | 1 |
| YAHA3-24DE (the pairing on screen) | — | 19,6005.74 | 24,0007.03 | 24,0007.03 | 82% | 2.10 | Yes | 1 |
Sold as, and units with identical certified values
Variants of the same model number
2 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
1 of 2 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
Product history
- YOHA2-36CB first appeared in the certified data between November 2024 and February 2025.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Jul 9, 2025
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read