Heat Pump List

Tools

WFPU18Z363C

WFPU18Z363C is in the certified data.

Its certified full-speed heating output at 5°F is 23,200–26,000 Btu/h, 76–82% of its 47°F rating (tests at different compressor speeds), depending on the pairing.

Friedrich · central heat pump

WFPU18Z363C is in the certified data as of Sep 19, 2026. WFPU18Z363C changed its certified heat output at 47°F on AHRI certificate 216014863 from 29,000 Btu/h to 28,200 Btu/h in the certified data between March 2025 and May 2025.

4 certified pairings with 2 different figures. See all

Certified heating and cooling

Heating at 47°F

28,200

18,700 at 17°F

23,200 at 5°F

Btu/h, certified

2.07 COP at 5°F

Cooling at 95°F

28,200

Btu/h, certified

EER2 10.1 at 95°F

SEER2 17.0

Heating and cooling by outdoor temperature

Certified heating at 5, 17, and 47°F and cooling at 95°F for WFPU18Z363C, by outdoor temperature Heating: 23,200 Btu/h at 5°F, 18,700 Btu/h at 17°F, 28,200 Btu/h at 47°F. Cooling: 28,200 Btu/h at 95°F. The bars start at zero. Median of 2.5-ton central models: 22,400 Btu/h at 5°F, 20,600 Btu/h at 17°F, 30,000 Btu/h at 47°F, 30,000 Btu/h at 95°F. 0 10,000 20,000 30,000 40,000 Btu/h 23,200 5°F 18,700 17°F 28,200 47°F 28,200 95°F Outdoor temperature (°F)
  • Heating output
  • Cooling output
  • Median of 2.5-ton central models
  • Example heating load
  • Example cooling load
  • Frosting range, 17 to 45°F

This pairing delivers 28,200 Btu/h of heat at 47°F, 18,700 Btu/h at 17°F, and 23,200 Btu/h at 5°F, 82% of its 47°F rating. It delivers 28,200 Btu/h of cooling at 95°F. At 5°F that is 700 Btu/h above the example heating load of 22,500 Btu/h; at 95°F it is 16,700 Btu/h above the example cooling load of 11,500 Btu/h.

Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 2.5-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.

The dashed lines are example loads for a typical area of about 950 sq ft where winters reach 5°F: heating runs from 22,500 Btu/h at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 11,500 Btu/h at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.

Calculate heating and cooling for your house

AHRI certificate 214779539 · listed by Friedrich · certified Jan 30, 2025 · 3 pairings share these values

All rebate programs and their published thresholds

Certified output and power use

Certified output for the selected pairingThe four bars share one scale. The comparison is with the median of 2.5-ton central models. Heating tests run at 70°F indoors. The cooling test runs at 80°F indoors.
Outdoor temperature Certified outputBtu/h One scale vs class median COPat 5°F
5°Ffull speed 23,2006.80 kW +4% 2.07
17°Ffull speed 18,7005.48 kW −9% NR
47°Fnormal speed 28,2008.26 kW −6% NR
95°Fcooling, full load 28,2008.26 kW — NR

EER2 10.1 in that test. SEER2 17.0 over the modeled cooling season.

Power use at each temperature

Electrical input in the 5°F full-speed test
3.28kW
Electrical input in the 95°F cooling test
2.79kW
Seasonal average heating COP
2.49

These exclude backup resistance heat.

Updated Sep 19, 2026 · Methodology

How it compares with other 30,000 Btu heat pumps

2.5-ton central models

This pairing at 5°F
23,200 Btu/h
This unit at 5°F median across its pairings
23,200 Btu/h
Median of 2.5-ton central models at 5°F
22,400 Btu/h
Models in this group
288

This unit is above 51% of them, at number 140 of 288 by heat at 5°F. The middle half of the group runs 14,250 to 30,000 Btu/h.

This size class is defined by cooling capacity, so cooling is not compared here.

Closest models by heat at 5°F

Every 30,000 Btu (2.5-ton) unit, ranked by cooling efficiency, then heating efficiency

Certified values for WFPU18Z363C

4 pairings · 4 AHRI certificates

This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.

Certified values for WFPU18Z363C
This pairingAll pairings
Heating
Heat output at 47°F normal speed 28,200 Btu/h 28,200–34,000 Btu/h
Heat output at 17°F full speed 18,700 Btu/h 18,700–24,000 Btu/h
Heat output at 5°F full speed 23,200 Btu/h 23,200–26,000 Btu/h
Heat output below 5°F NR NR
Cold output 5°F output as a % of the 47°F rating 82%
COP at 5°F full speed 2.07 2.05–2.07
HSPF2 Region IV 8.5 8.5–9.5
Cooling
Cooling capacity at 95°F full-load test 28,200 Btu/h 28,200–34,000 Btu/h
EER2 at 95°F 10.1 10.1
SEER2 cooling season 17.0 17.0–18.0
Cooling at other temperatures NR NR
Equipment and listing
Refrigerant R-410A
Compressor Variable speed
Indoor unit FRH2TZ3617STANN 4 indoor units
FurnaceNo furnace None
Cold-climate designation EPA's designation, as published Yes On every pairing
ENERGY STAR Most Efficient EPA's designation, as published Yes On every pairing
Where it is sold US and Canada US and Canada
Model string as certified WFPU18Z363C

Pairings, by indoor-unit class

4 indoor units · 4 certified pairings

One row per indoor unit certified with this outdoor unit.

Air handler · 4 indoor units

  1. DRAH2TA3617STANN brand not stated 23,200 Btu/hat 5°F, full speed

    1 pairing · 47°F 28,200 Btu/h · 95°F cooling 28,200 Btu/h · Cold output 82% · COP 2.07

  2. FRH2TZ3617STANN (the pairing on screen) brand not stated 23,200 Btu/hat 5°F, full speed

    1 pairing · 47°F 28,200 Btu/h · 95°F cooling 28,200 Btu/h · Cold output 82% · COP 2.07

  3. RH2TZ3617STANN brand not stated 23,200 Btu/hat 5°F, full speed

    1 pairing · 47°F 28,200 Btu/h · 95°F cooling 28,200 Btu/h · Cold output 82% · COP 2.07

  4. WFH36Z193C brand not stated 26,000 Btu/hat 5°F, full speed

    1 pairing · 47°F 34,000 Btu/h · 95°F cooling 34,000 Btu/h · Cold output 76% · COP 2.05

Indoor units in the air handler class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · normal speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
DRAH2TA3617STANN — 23,200 28,200 28,200 82% 2.07 Yes 1
FRH2TZ3617STANN (the pairing on screen) — 23,200 28,200 28,200 82% 2.07 Yes 1
RH2TZ3617STANN — 23,200 28,200 28,200 82% 2.07 Yes 1
WFH36Z193C — 26,000 34,000 34,000 76% 2.05 Yes 1

The share is heat output at 5°F divided by the 47°F rating.

Showing 4 of 4 indoor units

Sold as, and units with identical certified values

Brands listing this model number

Model number as listed

Product history

  • WFPU18Z363C changed its certified heat output at 47°F on AHRI certificate 216014863 from 29,000 Btu/h to 28,200 Btu/h in the certified data between March 2025 and May 2025.
  • WFPU18Z363C changed its certified heat output at 47°F on 3 pairings in the certified data between February 2025 and March 2025. The new figure is lower on all 3.
  • WFPU18Z363C was in the certified data by September 2024.

History and definitions

History

First certified record
Most recent certified record
Measurements reported
Jan 30, 2025
Status
In the certified data

Field definitions

COP
Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
HSPF2
Heating efficiency over a typical season. Higher uses less electricity.
SEER2
Cooling efficiency over a typical season. Higher uses less electricity.
EER2
Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
Cold output
Heat output at 5°F as a percentage of the 47°F rating.
% of rating at 17°F
Heat output at 17°F as a percentage of the 47°F rating.

NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read

Cite or print this page

Heat Pump List, “WFPU18Z363C — certified heat output”. Certified figures dated , checked daily.