5TWX7036A1
5TWX7036A1 is in the certified data.
Its certified full-speed heating output at 5°F is 23,600–25,000 Btu/h6.92–7.33 kW, 73–75% of its 47°F rating (tests at different compressor speeds), depending on the pairing.
Trane · central heat pump
5TWX7036A1 is in the certified data as of Sep 19, 2026. 5TWX7036A1 changed its certified COP at 5°F on 83 pairings in the certified data between August 2025 and September 2026. The new figure is lower on all 83.
- 30,000 Btu (2.5-ton)
- Central
- Two-stage
- US and Canada
Certified heating and cooling
Heating at 47°F
32,4009.50NR
No 47°F rating for this pairing.
21,2006.21NR at 17°F
24,0007.03NR at 5°F
Btu/hkW, certified
2.10NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 32,400 Btu/h9.50 kW of heat at 47°F, 21,200 Btu/h6.21 kW at 17°F, and 24,000 Btu/h7.03 kW at 5°F, 74% of its 47°F rating. It delivers 32,600 Btu/h9.55 kW of cooling at 95°F. At 5°F that is 1,500 Btu/h0.44 kW above the example heating load of 22,500 Btu/h6.59 kW; at 95°F it is 21,100 Btu/h6.18 kW above the example cooling load of 11,500 Btu/h3.37 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at high stage; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 2.5-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 950 sq ft where winters reach 5°F: heating runs from 22,500 Btu/h6.59 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 11,500 Btu/h3.37 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 216764285 · listed by Trane · certified Oct 27, 2025 · 8 pairings share these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 24,0007.03 kW | +7% | 2.10 | |
| 17°Ffull speed | 21,2006.21 kW | +3% | NR | |
| 47°Fhigh stage | 32,4009.50 kW | +8% | NR | |
| 95°Fcooling, full load | 32,6009.55 kW | — | NR |
EER2 11.7 in that test. SEER2 17.1 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 3.35kW
- Electrical input in the 95°F cooling test
- 2.79kW
- Seasonal average heating COP
- 2.55
These exclude backup resistance heat.
How it compares with other 30,000 Btu heat pumps
2.5-ton central models
- This pairing at 5°F
- 24,000 Btu/h7.03 kWNR
- This unit at 5°F median across its pairings
- 24,000 Btu/h7.03 kW
- Median of 2.5-ton central models at 5°F
- 22,400 Btu/h6.56 kW
- Models in this group
- 288
This unit is above 52% of them, at number 139 of 288 by heat at 5°F. The middle half of the group runs 14,250 to 30,000 Btu/h.
Closest models by heat at 5°F
- HVH837GKA2ACiQ, Airquest + 2 more · 24,200 Btu/h
- 25VNA837A*031*Carrier · 24,000 Btu/h
- 38MURAQ30AB3Airquest, Arcoaire + 10 more · 24,000 Btu/h
- DLCURAH30ABKAirquest, Arcoaire + 12 more · 24,000 Btu/h
- UHO30-NB-QMitsutomo · 24,000 Btu/h
- WFPU18Z363CFriedrich · 23,200 Btu/h
Every 30,000 Btu (2.5-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for 5TWX7036A1
519 pairings · 519 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F high stage | 32,400 Btu/h9.50 kWNR | 31,400–33,800 Btu/h9.20–9.91 kW |
| Heat output at 17°F full speed | 21,200 Btu/h6.21 kWNR | 20,800–30,200 Btu/h6.10–8.85 kW |
| Heat output at 5°F full speed | 24,000 Btu/h7.03 kWNR | 23,600–25,000 Btu/h6.92–7.33 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 74%NR | |
| COP at 5°F full speed | 2.10NR | 1.90–2.20 |
| HSPF2 Region IV | 8.7NR | 8.1–9.4 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 32,600 Btu/h9.55 kWNR | 31,400–34,800 Btu/h9.20–10.20 kW |
| EER2 at 95°F | 11.7NR | 11.0–12.7 |
| SEER2 cooling season | 17.1NR | 15.2–18.0 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-454B | |
| Compressor | Two-stage | |
| Indoor unit | 5PX*C005AS3 | 56 indoor units |
| Furnace | S8X1C080M5PSC | 96 furnaces |
| Cold-climate designation EPA's designation, as published | Yes | On some pairings |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On some pairings |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | 5TWX7036A1 | |
Pairings, by indoor-unit class
56 indoor units · 519 certified pairings
One row per indoor unit certified with this outdoor unit.
Furnace paired · 1 indoor unit
-
5PX*BD04AS3 (the pairing on screen) brand not stated 24,600 Btu/h7.21 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · high stage | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| 5PX*BD04AS3 (the pairing on screen) | — | 24,6007.21 | 33,4009.79 | 32,6009.55 | 73% | 1.90 | NC | 24 |
Air handler · 9 indoor units
-
5TXCB006AS3 (the pairing on screen) brand not stated 24,000 Btu/h7.03 kWat 5°F, full speed
-
5PX*B006AS3 (the pairing on screen) brand not stated 24,000 Btu/h7.03 kWat 5°F, full speed
-
5TXCB004AS3 (the pairing on screen) brand not stated 23,800 Btu/h6.98 kWat 5°F, full speed
-
5PX*B004AS3 (the pairing on screen) brand not stated 23,800 Btu/h6.98 kWat 5°F, full speed
-
5PX*BD06AS3 (the pairing on screen) brand not stated 24,400 Btu/h7.15 kWat 5°F, full speed
-
5PX*C007AS3 (the pairing on screen) brand not stated 24,200 Btu/h7.09 kWat 5°F, full speed
-
5TXCC007AS3 (the pairing on screen) brand not stated 24,200 Btu/h7.09 kWat 5°F, full speed
-
5PX*C009AS3 (the pairing on screen) brand not stated 24,000 Btu/h7.03 kWat 5°F, full speed
-
5TXCC009AS3 (the pairing on screen) brand not stated 24,000 Btu/h7.03 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · high stage | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| 5TXCB006AS3 (the pairing on screen) | — | 24,0007.03 | 32,6009.55 | 33,0009.67 | 74% | 2.10 | Yes | 53 |
| 5PX*B006AS3 (the pairing on screen) | — | 24,0007.03 | 32,4009.50 | 33,2009.73 | 74% | 2.10 | Yes | 45 |
| 5TXCB004AS3 (the pairing on screen) | — | 23,8006.98 | 32,2009.44 | 32,2009.44 | 74% | 2.10 | Yes | 38 |
| 5PX*B004AS3 (the pairing on screen) | — | 23,8006.98 | 32,2009.44 | 32,2009.44 | 74% | 2.10 | Yes | 37 |
| 5PX*BD06AS3 (the pairing on screen) | — | 24,4007.15 | 33,2009.73 | 33,0009.67 | 73% | 2.00 | Yes | 33 |
| 5PX*C007AS3 (the pairing on screen) | — | 24,2007.09 | 32,6009.55 | 33,6009.85 | 74% | 2.10 | Yes | 29 |
| 5TXCC007AS3 (the pairing on screen) | — | 24,2007.09 | 32,6009.55 | 33,6009.85 | 74% | 2.10 | Yes | 29 |
| 5PX*C009AS3 (the pairing on screen) | — | 24,0007.03 | 32,4009.50 | 34,20010.02 | 74% | 2.20 | Yes | 25 |
| 5TXCC009AS3 (the pairing on screen) | — | 24,0007.03 | 32,4009.50 | 34,20010.02 | 74% | 2.20 | Yes | 25 |
Sold as, and units with identical certified values
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
Product history
- 5TWX7036A1 changed its certified COP at 5°F on 83 pairings in the certified data between August 2025 and September 2026. The new figure is lower on all 83.
- 5TWX7036A1 first appeared in the certified data between February 2025 and March 2025.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Oct 27, 2025
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read