YOHA2-60AA
YOHA2-60AA is in the certified data.
Its certified full-speed heating output at 5°F is 28,000–38,500 Btu/h8.21–11.28 kW, 70–83% of its 47°F rating (tests at different compressor speeds), depending on the pairing.
Yiso · central heat pump
YOHA2-60AA is in the certified data as of Sep 19, 2026.
- 54,000 Btu (4.5-ton)
- Central
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
46,00013.48NR
No 47°F rating for this pairing.
38,00011.14NR at 17°F
32,4009.50NR at 5°F
Btu/hkW, certified
1.95NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 46,000 Btu/h13.48 kW of heat at 47°F, 38,000 Btu/h11.14 kW at 17°F, and 32,400 Btu/h9.50 kW at 5°F, 70% of its 47°F rating. It delivers 45,000 Btu/h13.19 kW of cooling at 95°F. At 5°F that is 7,600 Btu/h2.23 kW short of the example heating load of 40,000 Btu/h11.72 kW; at 95°F it is 25,000 Btu/h7.33 kW above the example cooling load of 20,000 Btu/h5.86 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 4.5-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 1,650 sq ft where winters reach 5°F: heating runs from 40,000 Btu/h11.72 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 20,000 Btu/h5.86 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 214290146 · listed by YISO · certified Aug 5, 2026 · 3 pairings share these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 32,4009.50 kW | −19% | 1.95 | |
| 17°Ffull speed | 38,00011.14 kW | +1% | NR | |
| 47°Fnormal speed | 46,00013.48 kW | −18% | NR | |
| 95°Fcooling, full load | 45,00013.19 kW | — | NR |
EER2 11.7 in that test. SEER2 18.0 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 4.87kW
- Electrical input in the 95°F cooling test
- 3.85kW
- Seasonal average heating COP
- 2.58
These exclude backup resistance heat.
How it compares with other 54,000 Btu heat pumps
4.5-ton central models
- This pairing at 5°F
- 32,400 Btu/h9.50 kWNR
- This unit at 5°F median across its pairings
- 32,400 Btu/h9.50 kW
- Median of 4.5-ton central models at 5°F
- 40,000 Btu/h11.72 kW
- Models in this group
- 343
This unit is above 25% of them, at number 257 of 343 by heat at 5°F. The middle half of the group runs 32,000 to 45,000 Btu/h.
Closest models by heat at 5°F
- RP15AZ60AJ2NRheem and Ruud · 33,600 Btu/h
- HL19B6021Champion, Fraser-Johnston + 2 more · 32,600 Btu/h
- YZT60B21York · 32,600 Btu/h
- YH560E2S11York · 31,600 Btu/h
- YH660E2S11York · 31,400 Btu/h
- PHE6B6024Champion, Coleman + 4 more · 31,200 Btu/h
Every 54,000 Btu (4.5-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for YOHA2-60AA
34 pairings · 34 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 46,000 Btu/h13.48 kWNR | 35,000–55,000 Btu/h10.26–16.12 kW |
| Heat output at 17°F full speed | 38,000 Btu/h11.14 kWNR | 30,000–43,500 Btu/h8.79–12.75 kW |
| Heat output at 5°F full speed | 32,400 Btu/h9.50 kWNR | 28,000–38,500 Btu/h8.21–11.28 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 70%NR | |
| COP at 5°F full speed | 1.95NR | 1.85–2.10 |
| HSPF2 Region IV | 8.8NR | 8.3–9.5 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 45,000 Btu/h13.19 kWNR | 33,000–54,000 Btu/h9.67–15.83 kW |
| EER2 at 95°F | 11.7NR | 10.8–12.5 |
| SEER2 cooling season | 18.0NR | 15.2–19.5 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-410A | |
| Compressor | Variable speed | |
| Indoor unit | YLCN2-4248CA | 16 indoor units |
| Furnace | MGH96M100C5A | 14 furnaces |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On some pairings |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | YOHA2-60AA | |
Pairings, by indoor-unit class
16 indoor units · 34 certified pairings
One row per indoor unit certified with this outdoor unit.
Furnace paired · 2 indoor units
-
YLCN2-3036BA (the pairing on screen) brand not stated 28,000 Btu/h8.21 kWat 5°F, full speed
-
YLSN2-3036CA (the pairing on screen) brand not stated 28,000 Btu/h8.21 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| YLCN2-3036BA (the pairing on screen) | — | 28,0008.21 | 35,00010.26 | 33,0009.67 | 80% | 1.95 | Yes | 5 |
| YLSN2-3036CA (the pairing on screen) | — | 28,0008.21 | 35,00010.26 | 33,0009.67 | 80% | 1.95 | Yes | 2 |
Air handler · 8 indoor units
-
YLCN2-4248CA (the pairing on screen) brand not stated 32,400 Btu/h9.50 kWat 5°F, full speed
-
YLCN2-4860CA (the pairing on screen) brand not stated 37,800 Btu/h11.08 kWat 5°F, full speed
-
YLCN2-4860DA (the pairing on screen) brand not stated 37,800 Btu/h11.08 kWat 5°F, full speed
-
YAHA1-36BA (the pairing on screen) brand not stated 29,200 Btu/h8.56 kWat 5°F, full speed
-
YAHA1-48BA (the pairing on screen) brand not stated 34,400 Btu/h10.08 kWat 5°F, full speed
-
YAHA1-60BA (the pairing on screen) brand not stated 38,500 Btu/h11.28 kWat 5°F, full speed
-
YAHA2-36AA (the pairing on screen) brand not stated 29,200 Btu/h8.56 kWat 5°F, full speed
-
YAHA2-36CB (the pairing on screen) brand not stated 29,200 Btu/h8.56 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| YLCN2-4248CA (the pairing on screen) | — | 32,4009.50 | 46,00013.48 | 44,00012.90 | 70% | 1.95 | Yes | 7 |
| YLCN2-4860CA (the pairing on screen) | — | 37,80011.08 | 54,00015.83 | 52,00015.24 | 70% | 1.90 | Yes | 5 |
| YLCN2-4860DA (the pairing on screen) | — | 37,80011.08 | 54,00015.83 | 52,00015.24 | 70% | 1.90 | Yes | 4 |
| YAHA1-36BA (the pairing on screen) | — | 29,2008.56 | 36,00010.55 | 35,20010.32 | 81% | 1.90 | Yes | 1 |
| YAHA1-48BA (the pairing on screen) | — | 34,40010.08 | 48,00014.07 | 47,00013.77 | 72% | 2.10 | Yes | 1 |
| YAHA1-60BA (the pairing on screen) | — | 38,50011.28 | 55,00016.12 | 54,00015.83 | 70% | 1.90 | Yes | 1 |
| YAHA2-36AA (the pairing on screen) | — | 29,2008.56 | 35,00010.26 | 34,60010.14 | 83% | 1.90 | Yes | 1 |
| YAHA2-36CB (the pairing on screen) | — | 29,2008.56 | 36,00010.55 | 35,20010.32 | 81% | 1.90 | Yes | 1 |
Sold as, and units with identical certified values
Variants of the same model number
2 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
1 of 2 shown.
Other model numbers with identical certified values
2 units share this record. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
1 of 2 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Aug 5, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read