27VPA960A*030*

27VPA960A*030* is in the certified data.

Its certified full-speed heating output at 5°F is 39,000–42,000 Btu/h, 66–71% of its 47°F rating (tests at different compressor speeds), depending on the pairing.

Carrier · central heat pump

All 187 certified Carrier models

27VPA960A*030* is in the certified data as of Sep 19, 2026.

225 certified pairings with 105 different figures. See all

Certified heating and cooling

Heating at 47°F

58,000

48,500 at 17°F

40,500 at 5°F

Btu/h, certified

2.14 COP at 5°F

Cooling at 95°F

56,000

Btu/h, certified

EER2 11.0 at 95°F

SEER2 16.0

Heating and cooling by outdoor temperature

Certified heating at 5, 17, and 47°F and cooling at 95°F for 27VPA960A*030*, by outdoor temperature Heating: 40,500 Btu/h at 5°F, 48,500 Btu/h at 17°F, 58,000 Btu/h at 47°F. Cooling: 56,000 Btu/h at 95°F. The bars start at zero. Median of 4.5-ton central models: 40,000 Btu/h at 5°F, 37,800 Btu/h at 17°F, 56,000 Btu/h at 47°F, 55,000 Btu/h at 95°F. 0 20,000 40,000 60,000 80,000 Btu/h 40,500 5°F 48,500 17°F 58,000 47°F 56,000 95°F Outdoor temperature (°F)
  • Heating output
  • Cooling output
  • Median of 4.5-ton central models
  • Example heating load
  • Example cooling load
  • Frosting range, 17 to 45°F

This pairing delivers 58,000 Btu/h of heat at 47°F, 48,500 Btu/h at 17°F, and 40,500 Btu/h at 5°F, 70% of its 47°F rating. It delivers 56,000 Btu/h of cooling at 95°F. At 5°F that is 500 Btu/h above the example heating load of 40,000 Btu/h; at 95°F it is 36,000 Btu/h above the example cooling load of 20,000 Btu/h.

Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 4.5-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.

The dashed lines are example loads for a typical area of about 1,650 sq ft where winters reach 5°F: heating runs from 40,000 Btu/h at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 20,000 Btu/h at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.

Calculate heating and cooling for your house

AHRI certificate 217918318 · listed by Carrier · certified Sep 16, 2026 · 6 pairings share these values

Rebates where you live

Meets the recorded equipment thresholds of 59 programs in 36 states, provinces, or territories:Alabama (1), Arizona (1), California (3), Colorado (1), Connecticut (3), Idaho (2), Illinois (1), Kansas (1), Kentucky (1), Maryland (3), Massachusetts (3), Michigan (2), Minnesota (3), Mississippi (2), Nevada (1), New Hampshire (3), New Jersey (3), New York (4), North Carolina (1), Oregon (2), Pennsylvania (1), Rhode Island (3), South Carolina (1), Tennessee (1), Texas (2), Utah (1), Vermont (3), Washington (3), Wisconsin (1), British Columbia (3), Manitoba (1), New Brunswick (1), Newfoundland and Labrador (1), Nova Scotia (2), Ontario (1), Yukon (2).

All 59 programs by state and province

Alabama

Arizona

California

Colorado

Connecticut

Idaho

Illinois

Kansas

Kentucky

Maryland

Massachusetts

Michigan

Minnesota

Mississippi

Nevada

New Hampshire

New Jersey

New York

North Carolina

Oregon

Pennsylvania

Rhode Island

South Carolina

Tennessee

Texas

Utah

Vermont

Washington

Wisconsin

British Columbia

Manitoba

New Brunswick

Newfoundland and Labrador

Nova Scotia

Ontario

Yukon

Threshold comparisons use the unit’s median certified figures across its pairings, not the pairing selected above. Meeting these thresholds means the equipment may qualify; it does not guarantee approval. Service-area, installation, and product-list requirements also apply.

All rebate programs and their published thresholds

Certified output and power use

Certified output for the selected pairingThe four bars share one scale. The comparison is with the median of 4.5-ton central models. Heating tests run at 70°F indoors. The cooling test runs at 80°F indoors.
Outdoor temperature Certified outputBtu/h One scale vs class median COPat 5°F
5°Ffull speed 40,50011.87 kW +1% 2.14
17°Ffull speed 48,50014.21 kW +28% NR
47°Fnormal speed 58,00017.00 kW +4% NR
95°Fcooling, full load 56,00016.41 kW — NR

EER2 11.0 in that test. SEER2 16.0 over the modeled cooling season.

Power use at each temperature

Electrical input in the 5°F full-speed test
5.55kW
Electrical input in the 95°F cooling test
5.09kW
Seasonal average heating COP
2.64

These exclude backup resistance heat.

Updated Sep 19, 2026 · Methodology

How it compares with other 54,000 Btu heat pumps

4.5-ton central models

This pairing at 5°F
40,500 Btu/h
This unit at 5°F median across its pairings
40,500 Btu/h
Median of 4.5-ton central models at 5°F
40,000 Btu/h
Models in this group
343

This unit is above 56% of them, at number 151 of 343 by heat at 5°F. The middle half of the group runs 32,000 to 45,000 Btu/h.

This size class is defined by cooling capacity, so cooling is not compared here.

Among 54,000 Btu central models, each by its median certified pairing, highest first: 5°F output as a share of its 47°F rating, 244th of 343 (tied); HSPF2, 143rd of 358 (tied). Models without that figure are left out.

Similar ratings at 47°F

These central models share the nominal cooling size. Comparisons use each model’s median certified figures across pairings.

  • LRP15HPK60VP: 58,000 Btu/h at 47°F (this model: 58,500); 24,600 Btu/h at 5°F (this model: 40,500).
  • DLCURAH60ABK: 59,000 Btu/h at 47°F (this model: 58,500); 48,500 Btu/h at 5°F (this model: 40,500).
  • (C,H,T)5H8T60*K*AAA*: 57,500 Btu/h at 47°F (this model: 58,500); 30,200 Btu/h at 5°F (this model: 40,500).

Closest models by heat at 5°F

Every 54,000 Btu (4.5-ton) unit, ranked by cooling efficiency, then heating efficiency

Floor area at the cold test point

The median certified output of 40,500 Btu/h at 5°F matches the size calculator’s heating estimate for these floor areas, rounded to about 10 sq ft. Each range divides that output by the climate band’s heating rates.

Floor area by climate band and house condition
Climate bandHouse conditionBtu/h per sq ftApproximate sq ft
MildDrafty, little insulation24–42960–1,690
MildTypical16–261,560–2,530
MildTight, well insulated10–182,250–4,050
ColdDrafty, little insulation28–52780–1,450
ColdTypical18–301,350–2,250
ColdTight, well insulated12–221,840–3,380
Very coldDrafty, little insulation32–58700–1,270
Very coldTypical22–381,070–1,840
Very coldTight, well insulated16–281,450–2,530

This is an estimate, not a house-specific load calculation. Output stays at the 5°F test point for every band; it does not predict output at the band’s winter design temperature.

Certified values for 27VPA960A*030*

225 pairings · 225 AHRI certificates

This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.

Certified values for 27VPA960A*030*
This pairingAll pairings
Heating
Heat output at 47°F normal speed 58,000 Btu/h 56,500–62,000 Btu/h
Heat output at 17°F full speed 48,500 Btu/h 48,000–50,500 Btu/h
Heat output at 5°F full speed 40,500 Btu/h 39,000–42,000 Btu/h
Heat output below 5°F NR NR
Cold output 5°F output as a % of the 47°F rating 70%
COP at 5°F full speed 2.14 1.94–2.16
HSPF2 Region IV 9.0 8.0–9.0
Cooling
Cooling capacity at 95°F full-load test 56,000 Btu/h 54,000–57,500 Btu/h
EER2 at 95°F 11.0 10.0–12.0
SEER2 cooling season 16.0 15.2–17.5
Cooling at other temperatures NR NR
Equipment and listing
Refrigerant R-454B
Compressor Variable speed
Indoor unit CAA**6124AM* 13 indoor units
Furnace58SP*B110V21**22 48 furnaces
Cold-climate designation EPA's designation, as published NC On some pairings
ENERGY STAR Most Efficient EPA's designation, as published No On some pairings
Where it is sold US and Canada US and Canada
Model string as certified 27VPA960A*030*

Across 225 certified pairings with 13 indoor models: heat at 5°F 39,000 Btu/h with CVAMA6021XMA* to 42,000 Btu/h with CAA**6124AM*; HSPF2 8.0 with CVAMA6021XMA* to 9.0 with CAA**6024AM*; SEER2 15.2 with CAA**6024AM* to 17.5 with FT5BD6021X*. Endpoints name one indoor model where recorded; the furnace pairing can also change the figures.

Pairings, by indoor-unit class

13 indoor units · 225 certified pairings

One row per indoor unit certified with this outdoor unit.

Furnace paired · 9 indoor units

  1. CAA**6124AM* (the pairing on screen) brand not stated 41,000 Btu/hat 5°F, full speed

    44 pairings, 44 with a furnace · 47°F 58,000 Btu/h · 95°F cooling 56,000 Btu/h · Cold output 71% · COP 2.14

  2. CAA**6121AM* brand not stated 41,000 Btu/hat 5°F, full speed

    36 pairings, 36 with a furnace · 47°F 58,250 Btu/h · 95°F cooling 55,500 Btu/h · Cold output 70% · COP 2.00

  3. CAA**6024AM* brand not stated 40,500 Btu/hat 5°F, full speed

    33 pairings, 33 with a furnace · 47°F 57,500 Btu/h · 95°F cooling 54,500 Btu/h · Cold output 70% · COP 2.12

  4. CVAMA6021XMA* brand not stated 39,500 Btu/hat 5°F, full speed

    28 pairings, 28 with a furnace · 47°F 59,500 Btu/h · 95°F cooling 54,500 Btu/h · Cold output 66% · COP 1.95

  5. CVAVA6021XMA* brand not stated 39,500 Btu/hat 5°F, full speed

    25 pairings, 25 with a furnace · 47°F 60,000 Btu/h · 95°F cooling 54,500 Btu/h · Cold output 66% · COP 1.96

  6. CVAVA6121XMA* brand not stated 40,500 Btu/hat 5°F, full speed

    23 pairings, 23 with a furnace · 47°F 61,000 Btu/h · 95°F cooling 55,500 Btu/h · Cold output 66% · COP 1.96

  7. CVAMA6124XMA* brand not stated 41,000 Btu/hat 5°F, full speed

    14 pairings, 14 with a furnace · 47°F 61,500 Btu/h · 95°F cooling 56,500 Btu/h · Cold output 67% · COP 1.96

  8. CVAVA6124XMA* brand not stated 41,000 Btu/hat 5°F, full speed

    10 pairings, 10 with a furnace · 47°F 62,000 Btu/h · 95°F cooling 56,500 Btu/h · Cold output 66% · COP 1.96

  9. CSAH*6012AM* brand not stated 40,500 Btu/hat 5°F, full speed

    8 pairings, 8 with a furnace · 47°F 57,500 Btu/h · 95°F cooling 55,500 Btu/h · Cold output 70% · COP 2.04

Indoor units in the furnace paired class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · normal speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
CAA**6124AM* (the pairing on screen) — 41,000 58,000 56,000 71% 2.14 Yes 44
CAA**6121AM* — 41,000 58,250 55,500 70% 2.00 Yes 36
CAA**6024AM* — 40,500 57,500 54,500 70% 2.12 Yes 33
CVAMA6021XMA* — 39,500 59,500 54,500 66% 1.95 NC 28
CVAVA6021XMA* — 39,500 60,000 54,500 66% 1.96 NC 25
CVAVA6121XMA* — 40,500 61,000 55,500 66% 1.96 NC 23
CVAMA6124XMA* — 41,000 61,500 56,500 67% 1.96 NC 14
CVAVA6124XMA* — 41,000 62,000 56,500 66% 1.96 NC 10
CSAH*6012AM* — 40,500 57,500 55,500 70% 2.04 Yes 8

Air handler · 1 indoor unit

  1. F55AA*D60L* brand not stated 40,000 Btu/hat 5°F, full speed

    1 pairing · 47°F 57,500 Btu/h · 95°F cooling 56,000 Btu/h · Cold output 70% · COP 2.16

Indoor units in the air handler class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · normal speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
F55AA*D60L* — 40,000 57,500 56,000 70% 2.16 NC 1

The share is heat output at 5°F divided by the 47°F rating.

Showing 10 of 13 indoor units All 225 certified pairings

Sold as, and units with identical certified values

Brands listing this model number

Model number as listed

Variants of the same model number

4 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.

3 of 4 shown.

History and definitions

Other Performance 19 SEER2 VS HP models by nominal cooling size: 27VPA924A*030* (24,000 Btu), 27VPA936A*030* (36,000 Btu), 27VPA948A*030* (48,000 Btu).

History

First certified record
Most recent certified record
Measurements reported
Sep 16, 2026
Status
In the certified data

Field definitions

COP
Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
HSPF2
Heating efficiency over a typical season. Higher uses less electricity.
SEER2
Cooling efficiency over a typical season. Higher uses less electricity.
EER2
Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
Cold output
Heat output at 5°F as a percentage of the 47°F rating.
% of rating at 17°F
Heat output at 17°F as a percentage of the 47°F rating.

NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read

Cite or print this page

Heat Pump List, “27VPA960A*030* — certified heat output”. Certified figures dated , checked daily.