Heat Pump List

Tools

27VPA924A*030*

27VPA924A*030* is in the certified data.

Its certified full-speed heating output at 5°F is 20,000–22,200 Btu/h, 84–95% of its 47°F rating (tests at different compressor speeds), depending on the pairing.

Carrier · central heat pump

All 187 certified Carrier models

27VPA924A*030* is in the certified data as of Sep 19, 2026.

1,222 certified pairings with 399 different figures. See all

Certified heating and cooling

Heating at 47°F

25,000

20,600 at 17°F

21,400 at 5°F

Btu/h, certified

1.90 COP at 5°F

Cooling at 95°F

24,400

Btu/h, certified

EER2 13.5 at 95°F

SEER2 19.0

Heating and cooling by outdoor temperature

Certified heating at 5, 17, and 47°F and cooling at 95°F for 27VPA924A*030*, by outdoor temperature Heating: 21,400 Btu/h at 5°F, 20,600 Btu/h at 17°F, 25,000 Btu/h at 47°F. Cooling: 24,400 Btu/h at 95°F. The bars start at zero. Median of 2-ton central models: 19,000 Btu/h at 5°F, 19,200 Btu/h at 17°F, 24,000 Btu/h at 47°F, 24,000 Btu/h at 95°F. 0 10,000 20,000 30,000 Btu/h 21,400 5°F 20,600 17°F 25,000 47°F 24,400 95°F Outdoor temperature (°F)
  • Heating output
  • Cooling output
  • Median of 2-ton central models
  • Example heating load
  • Example cooling load
  • Frosting range, 17 to 45°F

This pairing delivers 25,000 Btu/h of heat at 47°F, 20,600 Btu/h at 17°F, and 21,400 Btu/h at 5°F, 86% of its 47°F rating. It delivers 24,400 Btu/h of cooling at 95°F. At 5°F that is 2,400 Btu/h above the example heating load of 19,000 Btu/h; at 95°F it is 14,900 Btu/h above the example cooling load of 9,500 Btu/h.

Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 2-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.

The dashed lines are example loads for a typical area of about 800 sq ft where winters reach 5°F: heating runs from 19,000 Btu/h at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 9,500 Btu/h at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.

Calculate heating and cooling for your house

AHRI certificate 217933981 · listed by Carrier · certified Sep 16, 2026 · 43 pairings share these values

Rebates where you live

Meets the recorded equipment thresholds of 70 programs in 37 states, provinces, or territories:Alabama (1), Arizona (1), California (3), Colorado (2), Connecticut (3), Delaware (2), Idaho (2), Illinois (1), Kansas (1), Kentucky (1), Maryland (3), Massachusetts (3), Michigan (2), Minnesota (3), Mississippi (2), Nevada (1), New Hampshire (3), New Jersey (7), New York (4), North Carolina (1), Oregon (2), Pennsylvania (4), Rhode Island (3), South Carolina (1), Tennessee (1), Texas (3), Utah (1), Vermont (3), Washington (3), Wisconsin (1), British Columbia (3), Manitoba (1), New Brunswick (1), Newfoundland and Labrador (1), Nova Scotia (2), Ontario (1), Yukon (2).

All 70 programs by state and province

Alabama

Arizona

California

Colorado

Connecticut

Delaware

Idaho

Illinois

Kansas

Kentucky

Maryland

Massachusetts

Michigan

Minnesota

Mississippi

Nevada

New Hampshire

New Jersey

New York

North Carolina

Oregon

Pennsylvania

Rhode Island

South Carolina

Tennessee

Texas

Utah

Vermont

Washington

Wisconsin

British Columbia

Manitoba

New Brunswick

Newfoundland and Labrador

Nova Scotia

Ontario

Yukon

Threshold comparisons use the unit’s median certified figures across its pairings, not the pairing selected above. Meeting these thresholds means the equipment may qualify; it does not guarantee approval. Service-area, installation, and product-list requirements also apply.

All rebate programs and their published thresholds

Certified output and power use

Certified output for the selected pairingThe four bars share one scale. The comparison is with the median of 2-ton central models. Heating tests run at 70°F indoors. The cooling test runs at 80°F indoors.
Outdoor temperature Certified outputBtu/h One scale vs class median COPat 5°F
5°Ffull speed 21,4006.27 kW +13% 1.90
17°Ffull speed 20,6006.04 kW +7% NR
47°Fnormal speed 25,0007.33 kW +4% NR
95°Fcooling, full load 24,4007.15 kW — NR

EER2 13.5 in that test. SEER2 19.0 over the modeled cooling season.

Power use at each temperature

Electrical input in the 5°F full-speed test
3.30kW
Electrical input in the 95°F cooling test
1.81kW
Seasonal average heating COP
2.49

These exclude backup resistance heat.

Updated Sep 19, 2026 · Methodology

How it compares with other 24,000 Btu heat pumps

2-ton central models

This pairing at 5°F
21,400 Btu/h
This unit at 5°F median across its pairings
21,400 Btu/h
Median of 2-ton central models at 5°F
19,000 Btu/h
Models in this group
565

This unit is above 73% of them, at number 152 of 565 by heat at 5°F. The middle half of the group runs 16,000 to 21,600 Btu/h.

This size class is defined by cooling capacity, so cooling is not compared here.

Among 24,000 Btu central models, each by its median certified pairing, highest first: 5°F output as a share of its 47°F rating, 141st of 565 (tied); HSPF2, 350th of 578 (tied). Models without that figure are left out.

Similar ratings at 47°F

These central models share the nominal cooling size. Comparisons use each model’s median certified figures across pairings.

  • C5H8T24*K*AAA*: The same 24,800 Btu/h rating at 47°F; 11,100 Btu/h at 5°F (this model: 21,400).
  • W5H8T24*K*AAA*: 24,600 Btu/h at 47°F (this model: 24,800); 11,000 Btu/h at 5°F (this model: 21,400).
  • 5HPL6024A1000A: 25,000 Btu/h at 47°F (this model: 24,800); 14,000 Btu/h at 5°F (this model: 21,400).

Closest models by heat at 5°F

Every 24,000 Btu (2-ton) unit, ranked by cooling efficiency, then heating efficiency

Floor area at the cold test point

The median certified output of 21,400 Btu/h at 5°F matches the size calculator’s heating estimate for these floor areas, rounded to about 10 sq ft. Each range divides that output by the climate band’s heating rates.

Floor area by climate band and house condition
Climate bandHouse conditionBtu/h per sq ftApproximate sq ft
MildDrafty, little insulation24–42510–890
MildTypical16–26820–1,340
MildTight, well insulated10–181,190–2,140
ColdDrafty, little insulation28–52410–760
ColdTypical18–30710–1,190
ColdTight, well insulated12–22970–1,780
Very coldDrafty, little insulation32–58370–670
Very coldTypical22–38560–970
Very coldTight, well insulated16–28760–1,340

This is an estimate, not a house-specific load calculation. Output stays at the 5°F test point for every band; it does not predict output at the band’s winter design temperature.

Certified values for 27VPA924A*030*

1,222 pairings · 1,222 AHRI certificates

This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.

Certified values for 27VPA924A*030*
This pairingAll pairings
Heating
Heat output at 47°F normal speed 25,000 Btu/h 22,400–25,800 Btu/h
Heat output at 17°F full speed 20,600 Btu/h 19,800–25,200 Btu/h
Heat output at 5°F full speed 21,400 Btu/h 20,000–22,200 Btu/h
Heat output below 5°F NR NR
Cold output 5°F output as a % of the 47°F rating 86%
COP at 5°F full speed 1.90 1.74–2.02
HSPF2 Region IV 8.5 8.0–10.0
Cooling
Cooling capacity at 95°F full-load test 24,400 Btu/h 22,200–25,400 Btu/h
EER2 at 95°F 13.5 11.5–14.0
SEER2 cooling season 19.0 15.2–19.5
Cooling at other temperatures NR NR
Equipment and listing
Refrigerant R-454B
Compressor Variable speed
Indoor unit CVAMA2517XMA* 60 indoor units
Furnace58SP*B045V14**12 87 furnaces
Cold-climate designation EPA's designation, as published Yes On some pairings
ENERGY STAR Most Efficient EPA's designation, as published Yes On some pairings
Where it is sold US and Canada US and Canada
Model string as certified 27VPA924A*030*

Across 1,222 certified pairings with 60 indoor models: heat at 5°F 20,000 Btu/h with CVAMA2414XMA*+TDR to 22,200 Btu/h with CVAVA3117XMA*; HSPF2 8.0 with CVAMA2414XMA* to 10.0 with CAA**2517AM*; SEER2 15.2 with CAA**2417AM* to 19.5 with FT5BD3617X*. Endpoints name one indoor model where recorded; the furnace pairing can also change the figures.

Pairings, by indoor-unit class

60 indoor units · 1,222 certified pairings

One row per indoor unit certified with this outdoor unit.

Furnace paired · 10 indoor units

  1. CSAH*3012AM* brand not stated 21,400 Btu/hat 5°F, full speed

    78 pairings, 78 with a furnace · 47°F 24,800 Btu/h · 95°F cooling 23,600 Btu/h · Cold output 86% · COP 1.92

  2. CSAH*2412AM* brand not stated 21,400 Btu/hat 5°F, full speed

    76 pairings, 76 with a furnace · 47°F 24,800 Btu/h · 95°F cooling 23,400 Btu/h · Cold output 86% · COP 1.85

  3. CSAH*3612AM* brand not stated 21,200 Btu/hat 5°F, full speed

    67 pairings, 67 with a furnace · 47°F 24,600 Btu/h · 95°F cooling 23,800 Btu/h · Cold output 86% · COP 1.92

  4. CAA**3721AM* brand not stated 21,200 Btu/hat 5°F, full speed

    65 pairings, 65 with a furnace · 47°F 24,600 Btu/h · 95°F cooling 24,400 Btu/h · Cold output 86% · COP 1.98

  5. CVAVA3621XMA* brand not stated 21,400 Btu/hat 5°F, full speed

    65 pairings, 65 with a furnace · 47°F 24,800 Btu/h · 95°F cooling 24,400 Btu/h · Cold output 86% · COP 1.88

  6. CVAVA3721XMA* brand not stated 21,400 Btu/hat 5°F, full speed

    65 pairings, 65 with a furnace · 47°F 25,000 Btu/h · 95°F cooling 24,600 Btu/h · Cold output 86% · COP 1.90

  7. CAA**2517AM* brand not stated 21,200 Btu/hat 5°F, full speed

    44 pairings, 44 with a furnace · 47°F 24,600 Btu/h · 95°F cooling 24,200 Btu/h · Cold output 86% · COP 1.98

  8. CAA**3717AM* brand not stated 21,200 Btu/hat 5°F, full speed

    44 pairings, 44 with a furnace · 47°F 24,600 Btu/h · 95°F cooling 24,000 Btu/h · Cold output 86% · COP 1.92

  9. CVAMA2417XMA* brand not stated 21,000 Btu/hat 5°F, full speed

    44 pairings, 44 with a furnace · 47°F 24,600 Btu/h · 95°F cooling 23,600 Btu/h · Cold output 85% · COP 1.88

  10. CVAMA2517XMA* (the pairing on screen) brand not stated 21,600 Btu/hat 5°F, full speed

    44 pairings, 44 with a furnace · 47°F 25,100 Btu/h · 95°F cooling 24,400 Btu/h · Cold output 86% · COP 1.90

Indoor units in the furnace paired class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · normal speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
CSAH*3012AM* — 21,400 24,800 23,600 86% 1.92 Yes 78
CSAH*2412AM* — 21,400 24,800 23,400 86% 1.85 Yes 76
CSAH*3612AM* — 21,200 24,600 23,800 86% 1.92 Yes 67
CAA**3721AM* — 21,200 24,600 24,400 86% 1.98 Yes 65
CVAVA3621XMA* — 21,400 24,800 24,400 86% 1.88 Yes 65
CVAVA3721XMA* — 21,400 25,000 24,600 86% 1.90 Yes 65
CAA**2517AM* — 21,200 24,600 24,200 86% 1.98 Yes 44
CAA**3717AM* — 21,200 24,600 24,000 86% 1.92 Yes 44
CVAMA2417XMA* — 21,000 24,600 23,600 85% 1.88 Yes 44
CVAMA2517XMA* (the pairing on screen) — 21,600 25,100 24,400 86% 1.90 Yes 44

The share is heat output at 5°F divided by the 47°F rating.

Showing 10 of 60 indoor units All 1,222 certified pairings

Sold as, and units with identical certified values

Brands listing this model number

Model number as listed

Variants of the same model number

4 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.

3 of 4 shown.

History and definitions

Other Performance 19 SEER2 VS HP models by nominal cooling size: 27VPA936A*030* (36,000 Btu), 27VPA948A*030* (48,000 Btu), 27VPA960A*030* (54,000 Btu).

History

First certified record
Most recent certified record
Measurements reported
Sep 16, 2026
Status
In the certified data

Field definitions

COP
Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
HSPF2
Heating efficiency over a typical season. Higher uses less electricity.
SEER2
Cooling efficiency over a typical season. Higher uses less electricity.
EER2
Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
Cold output
Heat output at 5°F as a percentage of the 47°F rating.
% of rating at 17°F
Heat output at 17°F as a percentage of the 47°F rating.

NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read

Cite or print this page

Heat Pump List, “27VPA924A*030* — certified heat output”. Certified figures dated , checked daily.
https://heatpumplist.com/model/27vpa924a_st030_st