38MGHBQ48EA3
38MGHBQ48EA3 is in the certified data.
Its certified full-speed heating output at 5°F is 42,500–45,000 Btu/h12.46–13.19 kW, 87–92% of its 47°F rating (tests at different compressor speeds), depending on the pairing.
Bryant, Carrier + 3 more · mini-split heat pump
38MGHBQ48EA3 is in the certified data as of Sep 19, 2026. 38MGHBQ48EA3 changed its certified HSPF2 on 10 pairings in the certified data between September 2024 and November 2024. The new figure is higher on all 10.
- 48,000 Btu (4-ton)
- Mini-split
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
49,00014.36NR
No 47°F rating for this pairing.
36,00010.55NR at 17°F
43,50012.75NR at 5°F
Btu/hkW, certified
2.00NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 49,000 Btu/h14.36 kW of heat at 47°F, 36,000 Btu/h10.55 kW at 17°F, and 43,500 Btu/h12.75 kW at 5°F, 89% of its 47°F rating. It delivers 47,500 Btu/h13.92 kW of cooling at 95°F. At 5°F that is 1,500 Btu/h0.44 kW above the example heating load of 42,000 Btu/h12.31 kW; at 95°F it is 26,500 Btu/h7.77 kW above the example cooling load of 21,000 Btu/h6.15 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 4-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 1,750 sq ft where winters reach 5°F: heating runs from 42,000 Btu/h12.31 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 21,000 Btu/h6.15 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 207642890 · listed by Carrier · certified Jun 25, 2026 · 5 pairings share these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 43,50012.75 kW | +4% | 2.00 | |
| 17°Ffull speed | 36,00010.55 kW | −5% | NR | |
| 47°Fnormal speed | 49,00014.36 kW | 0% | NR | |
| 95°Fcooling, full load | 47,50013.92 kW | — | NR |
EER2 11.7 in that test. SEER2 21.35 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 6.37kW
- Electrical input in the 95°F cooling test
- 4.06kW
- Seasonal average heating COP
- 2.75
These exclude backup resistance heat.
How it compares with other 48,000 Btu heat pumps
4-ton mini-split models
- This pairing at 5°F
- 43,500 Btu/h12.75 kWNR
- This unit at 5°F median across its pairings
- 43,500 Btu/h12.75 kW
- Median of 4-ton mini-split models at 5°F
- 42,000 Btu/h12.31 kW
- Models in this group
- 321
This unit is above 53% of them, at number 152 of 321 by heat at 5°F. The middle half of the group runs 37,000 to 47,500 Btu/h.
Closest models by heat at 5°F
- DIY-MULTI6-55HP230D-OMRCOOL · 46,000 Btu/h
- KUSXA481ALG · 44,000 Btu/h
- MMPD048S6S-1PLennox · 44,000 Btu/h
- MST483G22MHAAGoodman · 43,500 Btu/h
- AOUK048MSAN7Fujitsu · 42,000 Btu/h
- TMFX48HEI2NAS0U25Thermoflux · 42,000 Btu/h
Every 48,000 Btu (4-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for 38MGHBQ48EA3
15 pairings · 15 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 49,000 Btu/h14.36 kWNR | 49,000 Btu/h14.36 kW |
| Heat output at 17°F full speed | 36,000 Btu/h10.55 kWNR | 36,000 Btu/h10.55 kW |
| Heat output at 5°F full speed | 43,500 Btu/h12.75 kWNR | 42,500–45,000 Btu/h12.46–13.19 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 89%NR | |
| COP at 5°F full speed | 2.00NR | 2.00 |
| HSPF2 Region IV | 9.4NR | 9.0–9.8 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 47,500 Btu/h13.92 kWNR | 47,000–48,000 Btu/h13.77–14.07 kW |
| EER2 at 95°F | 11.7NR | 11.7 |
| SEER2 cooling season | 21.35NR | 20.9–21.8 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-410A | |
| Compressor | Variable speed | |
| Indoor unit | None listed | None |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On every pairing |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | 38MGHBQ48EA3 | |
Pairings, by indoor-unit class
15 certified pairings
One row per indoor unit certified with this outdoor unit.
Ductless indoor
-
None listed (the pairing on screen) BRYANT 43,500 Btu/h12.75 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| None listed (the pairing on screen) | BRYANT | 43,50012.75 | 49,00014.36 | 47,50013.92 | 89% | 2.00 | Yes | 15 |
Sold as, and units with identical certified values
Brands listing this model number
Other brands that list these model numbers
- Are Bryant and Carrier heat pumps the same?127 shared model numbers
- Are Bryant and Midea heat pumps the same?108 shared model numbers
- Are Bryant and WeatherMaker heat pumps the same?108 shared model numbers
- Are Bryant and Payne heat pumps the same?107 shared model numbers
Model number as listed
- 38MGHBQ48EA3 15 pairings
Variants of the same model number
24 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
- 4DHP2S48M-1PAirEase · Allied · Armstrong Air · Concord · Ducane
- A-KMH48PV-1Kerr
- A-VMH48PV-1Century · Comfort-Aire
- ACIQ-48Z-HH-M5B1HVAC · ACiQ · DIYCool · PolarWave · Stealth
- BMS500-AAM048-1CSXHCBosch
- BZ33-HYP485Z2-G2-PBreeze33
- C28MC548H21CanAir
- CCOXHAMZ548HPCustom Comfort
- CH-HPR48M-230VOC&H · Cooper&Hunter
- CVH-48-5SHComfortStar
- DEA48HOM25230X3Elios
- DIRM-48HXPRO28-5ZDirect Air
- DMA48HOM25230X3MoovAir
- M5H48H/O4S4PTrust Air Conditioners
- M5OG-48HFN1-M-[X]Eco Air
- M5OG-48HFN1-M-[X]-20MDV
- M5OG-48HFN1-M-[X]-20-LMDV
- MHMZ548DAConforto · EMI
- MLB048S4M-2PLennox
- MMCMHAQ48EA3Midea
- MST483F25MHAAFranklin
- ODUM5OG-48HFN1-M-[X]Kepler
- SENA-48HF-MOBSenville
23 of 24 shown.
Other model numbers with identical certified values
2 units share this record. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
1 of 2 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
Product history
- 38MGHBQ48EA3 changed its certified HSPF2 on 10 pairings in the certified data between September 2024 and November 2024. The new figure is higher on all 10.
- 38MGHBQ48EA3 was in the certified data by September 2024.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Jun 25, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read