4TWV0X48A1
4TWV0X48A1 is in the certified data.
Its certified full-speed heating output at 5°F is 27,000–28,600 Btu/h7.91–8.38 kW, 64–69% of its 47°F rating (tests at different compressor speeds), depending on the pairing.
Trane · central heat pump
4TWV0X48A1 is in the certified data as of Sep 19, 2026.
- 48,000 Btu (4-ton)
- Central
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
42,00012.31NR
No 47°F rating for this pairing.
35,80010.49NR at 17°F
27,8008.15NR at 5°F
Btu/hkW, certified
1.80NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 42,000 Btu/h12.31 kW of heat at 47°F, 35,800 Btu/h10.49 kW at 17°F, and 27,800 Btu/h8.15 kW at 5°F, 66% of its 47°F rating. It delivers 46,000 Btu/h13.48 kW of cooling at 95°F. At 5°F that is 8,700 Btu/h2.55 kW short of the example heating load of 36,500 Btu/h10.70 kW; at 95°F it is 28,000 Btu/h8.21 kW above the example cooling load of 18,000 Btu/h5.28 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 4-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 1,500 sq ft where winters reach 5°F: heating runs from 36,500 Btu/h10.70 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 18,000 Btu/h5.28 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 207805566 · listed by Trane · certified Jul 9, 2025 · 4 pairings share these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 27,8008.15 kW | −24% | 1.80 | |
| 17°Ffull speed | 35,80010.49 kW | +2% | NR | |
| 47°Fnormal speed | 42,00012.31 kW | −13% | NR | |
| 95°Fcooling, full load | 46,00013.48 kW | — | NR |
EER2 11.7 in that test. SEER2 19.5 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 4.53kW
- Electrical input in the 95°F cooling test
- 3.93kW
- Seasonal average heating COP
- 2.49
These exclude backup resistance heat.
How it compares with other 48,000 Btu heat pumps
4-ton central models
- This pairing at 5°F
- 27,800 Btu/h8.15 kWNR
- This unit at 5°F median across its pairings
- 27,800 Btu/h8.15 kW
- Median of 4-ton central models at 5°F
- 36,400 Btu/h10.67 kW
- Models in this group
- 408
This unit is above 28% of them, at number 294 of 408 by heat at 5°F. The middle half of the group runs 25,350 to 46,000 Btu/h.
Closest models by heat at 5°F
- RD16AY60AJVCFriedrich, Rheem + 3 more · 31,000 Btu/h
- 4TWV7X48A1Trane · 28,400 Btu/h
- 4TWV8X48A1Trane · 28,400 Btu/h
- YH648E2S11York · 27,200 Btu/h
- 4HP18V60PAC Pro, Allied + 2 more · 26,600 Btu/h
- 4SHP18LX160PAirEase and Armstrong Air · 26,600 Btu/h
Every 48,000 Btu (4-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for 4TWV0X48A1
118 pairings · 118 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 42,000 Btu/h12.31 kWNR | 40,500–44,000 Btu/h11.87–12.90 kW |
| Heat output at 17°F full speed | 35,800 Btu/h10.49 kWNR | 34,800–36,800 Btu/h10.20–10.79 kW |
| Heat output at 5°F full speed | 27,800 Btu/h8.15 kWNR | 27,000–28,600 Btu/h7.91–8.38 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 66%NR | |
| COP at 5°F full speed | 1.80NR | 1.66–1.90 |
| HSPF2 Region IV | 8.5NR | 7.8–8.7 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 46,000 Btu/h13.48 kWNR | 44,000–47,000 Btu/h12.90–13.77 kW |
| EER2 at 95°F | 11.7NR | 11.5–12.0 |
| SEER2 cooling season | 19.5NR | 19.0–20.0 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-410A | |
| Compressor | Variable speed | |
| Indoor unit | 4PX*DD60BS3+P0V0D000M50SC+RP | 51 indoor units |
| Furnace | No furnace | 27 furnaces |
| Cold-climate designation EPA's designation, as published | NC | NC |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On some pairings |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | 4TWV0X48A1 | |
Pairings, by indoor-unit class
51 indoor units · 118 certified pairings
One row per indoor unit certified with this outdoor unit.
Furnace paired · 9 indoor units
-
4TXCD010DS3 (the pairing on screen) brand not stated 27,400 Btu/h8.03 kWat 5°F, full speed
-
4PX*DU60BS3 (the pairing on screen) brand not stated 27,400 Btu/h8.03 kWat 5°F, full speed
-
4PX*CU60BS3 (the pairing on screen) brand not stated 28,000 Btu/h8.21 kWat 5°F, full speed
-
4TXCC009DS3 (the pairing on screen) brand not stated 28,000 Btu/h8.21 kWat 5°F, full speed
-
4TXCD008DS3 (the pairing on screen) brand not stated 27,800 Btu/h8.15 kWat 5°F, full speed
-
4PX*CD60BS3 (the pairing on screen) brand not stated 27,800 Btu/h8.15 kWat 5°F, full speed
-
4PX*CD60BS3+HORIZ-RT (the pairing on screen) brand not stated 27,900 Btu/h8.18 kWat 5°F, full speed
-
4PX*DU48BS3 (the pairing on screen) brand not stated 27,200 Btu/h7.97 kWat 5°F, full speed
-
4TXCC007DS3 (the pairing on screen) brand not stated 28,200 Btu/h8.26 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| 4TXCD010DS3 (the pairing on screen) | — | 27,4008.03 | 41,50012.16 | 45,50013.33 | 66% | 1.77 | NC | 24 |
| 4PX*DU60BS3 (the pairing on screen) | — | 27,4008.03 | 41,00012.02 | 45,50013.33 | 66% | 1.77 | NC | 23 |
| 4PX*CU60BS3 (the pairing on screen) | — | 28,0008.21 | 42,00012.31 | 46,50013.63 | 66% | 1.81 | NC | 8 |
| 4TXCC009DS3 (the pairing on screen) | — | 28,0008.21 | 42,00012.31 | 46,50013.63 | 66% | 1.81 | NC | 8 |
| 4TXCD008DS3 (the pairing on screen) | — | 27,8008.15 | 42,00012.31 | 45,25013.26 | 66% | 1.75 | NC | 4 |
| 4PX*CD60BS3 (the pairing on screen) | — | 27,8008.15 | 43,50012.75 | 47,00013.77 | 64% | 1.74 | NC | 3 |
| 4PX*CD60BS3+HORIZ-RT (the pairing on screen) | — | 27,9008.18 | 42,75012.53 | 46,75013.70 | 65% | 1.73 | NC | 2 |
| 4PX*DU48BS3 (the pairing on screen) | — | 27,2007.97 | 41,50012.16 | 44,50013.04 | 66% | 1.71 | NC | 2 |
| 4TXCC007DS3 (the pairing on screen) | — | 28,2008.26 | 44,00012.90 | 46,00013.48 | 64% | 1.70 | NC | 2 |
Air handler · 1 indoor unit
-
4PX*BU48BS3+P0V0B000M40SC+RP (the pairing on screen) brand not stated 27,600 Btu/h8.09 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| 4PX*BU48BS3+P0V0B000M40SC+RP (the pairing on screen) | — | 27,6008.09 | 42,00012.31 | 44,00012.90 | 66% | 1.73 | NC | 1 |
Sold as, and units with identical certified values
Variants of the same model number
2 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
1 of 2 shown.
Other model numbers with identical certified values
2 units share this record. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
1 of 2 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Jul 9, 2025
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read