YH648E2S11
YH648E2S11 is in the certified data.
Its certified full-speed heating output at 5°F is 25,000–27,800 Btu/h7.33–8.15 kW, 52–59% of its 47°F rating (tests at different compressor speeds), depending on the pairing.
York · central heat pump
YH648E2S11 is in the certified data as of Sep 19, 2026.
- 48,000 Btu (4-ton)
- Central
- Two-stage
- US and Canada
Certified heating and cooling
Heating at 47°F
49,50014.51NR
No 47°F rating for this pairing.
33,4009.79NR at 17°F
27,2007.97NR at 5°F
Btu/hkW, certified
2.28NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 49,500 Btu/h14.51 kW of heat at 47°F, 33,400 Btu/h9.79 kW at 17°F, and 27,200 Btu/h7.97 kW at 5°F, 55% of its 47°F rating. It delivers 47,000 Btu/h13.77 kW of cooling at 95°F. At 5°F that is 9,300 Btu/h2.73 kW short of the example heating load of 36,500 Btu/h10.70 kW; at 95°F it is 29,000 Btu/h8.50 kW above the example cooling load of 18,000 Btu/h5.28 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at high stage; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 4-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 1,500 sq ft where winters reach 5°F: heating runs from 36,500 Btu/h10.70 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 18,000 Btu/h5.28 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 217019118 · listed by York · certified Jul 15, 2026 · 20 pairings share these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Fone compressor speed | 27,2007.97 kW | −25% | 2.28 | |
| 17°Fone compressor speed | 33,4009.79 kW | −5% | NR | |
| 47°Fone compressor speed | 49,50014.51 kW | +3% | NR | |
| 95°Fcooling, full load | 47,00013.77 kW | — | NR |
EER2 12.0 in that test. SEER2 16.0 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 3.50kW
- Electrical input in the 95°F cooling test
- 3.92kW
- Seasonal average heating COP
- 2.37
These exclude backup resistance heat.
How it compares with other 48,000 Btu heat pumps
4-ton central models
- This pairing at 5°F
- 27,200 Btu/h7.97 kWNR
- This unit at 5°F median across its pairings
- 27,200 Btu/h7.97 kW
- Median of 4-ton central models at 5°F
- 36,400 Btu/h10.67 kW
- Models in this group
- 408
This unit is above 27% of them, at number 296 of 408 by heat at 5°F. The middle half of the group runs 25,350 to 46,000 Btu/h.
Closest models by heat at 5°F
- 4TWV7X48A1Trane · 28,400 Btu/h
- 4TWV8X48A1Trane · 28,400 Btu/h
- 4TWV0X48A1Trane · 27,800 Btu/h
- 4HP18V60PAC Pro, Allied + 2 more · 26,600 Btu/h
- 4SHP18LX160PAirEase and Armstrong Air · 26,600 Btu/h
- RD17AZ48AJ3NFriedrich, Rheem + 3 more · 26,400 Btu/h
Every 48,000 Btu (4-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for YH648E2S11
554 pairings · 554 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F high stage | 49,500 Btu/h14.51 kWNR | 46,000–50,000 Btu/h13.48–14.65 kW |
| Heat output at 17°F full speed | 33,400 Btu/h9.79 kWNR | 31,800–34,000 Btu/h9.32–9.96 kW |
| Heat output at 5°F full speed | 27,200 Btu/h7.97 kWNR | 25,000–27,800 Btu/h7.33–8.15 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 55%NR | |
| COP at 5°F full speed | 2.28NR | 2.00–2.40 |
| HSPF2 Region IV | 8.1NR | 7.8–8.1 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 47,000 Btu/h13.77 kWNR | 45,000–49,000 Btu/h13.19–14.36 kW |
| EER2 at 95°F | 12.0NR | 11.7–12.0 |
| SEER2 cooling season | 16.0NR | 15.2–16.0 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-454B | |
| Compressor | Two-stage | |
| Indoor unit | CTF60C5CGS1+JMC16C2SN1 | 141 indoor units |
| Furnace | No furnace | 43 furnaces |
| Cold-climate designation EPA's designation, as published | NC | NC |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On some pairings |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | YH648E2S11 | |
Pairings, by indoor-unit class
141 indoor units · 554 certified pairings
One row per indoor unit certified with this outdoor unit.
Furnace paired · 6 indoor units
-
CTF60C5CGS1 (the pairing on screen) brand not stated 27,300 Btu/h8.00 kWat 5°F, full speed
-
CTF60C5CGS2 (the pairing on screen) brand not stated 27,300 Btu/h8.00 kWat 5°F, full speed
-
CTM60C5CGS1 (the pairing on screen) brand not stated 27,200 Btu/h7.97 kWat 5°F, full speed
-
CTM60C5CGS2 (the pairing on screen) brand not stated 27,200 Btu/h7.97 kWat 5°F, full speed
-
CTU60C5XGS1+TXV (the pairing on screen) brand not stated 27,300 Btu/h8.00 kWat 5°F, full speed
-
CTU60C5XGS2+TXV (the pairing on screen) brand not stated 27,300 Btu/h8.00 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · high stage | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| CTF60C5CGS1 (the pairing on screen) | — | 27,3008.00 | 49,50014.51 | 46,00013.48 | 55% | 2.24 | NC | 36 |
| CTF60C5CGS2 (the pairing on screen) | — | 27,3008.00 | 49,50014.51 | 46,00013.48 | 55% | 2.24 | NC | 36 |
| CTM60C5CGS1 (the pairing on screen) | — | 27,2007.97 | 48,00014.07 | 46,00013.48 | 57% | 2.26 | NC | 36 |
| CTM60C5CGS2 (the pairing on screen) | — | 27,2007.97 | 48,00014.07 | 46,00013.48 | 57% | 2.26 | NC | 36 |
| CTU60C5XGS1+TXV (the pairing on screen) | — | 27,3008.00 | 49,50014.51 | 46,00013.48 | 55% | 2.24 | NC | 36 |
| CTU60C5XGS2+TXV (the pairing on screen) | — | 27,3008.00 | 49,50014.51 | 46,00013.48 | 55% | 2.24 | NC | 36 |
Air handler · 4 indoor units
-
CTF60C5CHS1 (the pairing on screen) brand not stated 27,200 Btu/h7.97 kWat 5°F, full speed
-
CTF60C5CHS2 (the pairing on screen) brand not stated 27,200 Btu/h7.97 kWat 5°F, full speed
-
CTM60C5CHS1 (the pairing on screen) brand not stated 27,000 Btu/h7.91 kWat 5°F, full speed
-
CTM60C5CHS2 (the pairing on screen) brand not stated 27,000 Btu/h7.91 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · high stage | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| CTF60C5CHS1 (the pairing on screen) | — | 27,2007.97 | 47,00013.77 | 48,00014.07 | 58% | 2.32 | NC | 37 |
| CTF60C5CHS2 (the pairing on screen) | — | 27,2007.97 | 47,00013.77 | 48,00014.07 | 58% | 2.32 | NC | 37 |
| CTM60C5CHS1 (the pairing on screen) | — | 27,0007.91 | 46,50013.63 | 48,00014.07 | 58% | 2.32 | NC | 37 |
| CTM60C5CHS2 (the pairing on screen) | — | 27,0007.91 | 46,50013.63 | 48,00014.07 | 58% | 2.32 | NC | 37 |
Sold as, and units with identical certified values
Variants of the same model number
2 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
1 of 2 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
Product history
- YH648E2S11 first appeared in the certified data between March 2025 and May 2025.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Jul 15, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read