RD17AZ48AJ3N
RD17AZ48AJ3N is in the certified data.
Its certified full-speed heating output at 5°F is 25,600–40,500 Btu/h7.50–11.87 kW, 53–84% of its 47°F rating (tests at different compressor speeds), depending on the pairing.
Friedrich, Rheem + 3 more · central heat pump
RD17AZ48AJ3N is in the certified data as of Sep 19, 2026. RD17AZ48AJ3N changed its certified heat output at 47°F on 15 pairings from 45,500 Btu/h to 48,000 Btu/h in the certified data between November 2024 and September 2026.
- 48,000 Btu (4-ton)
- Central
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
48,00014.07NR
No 47°F rating for this pairing.
33,2009.73NR at 17°F
26,4007.74NR at 5°F
Btu/hkW, certified
2.20NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 48,000 Btu/h14.07 kW of heat at 47°F, 33,200 Btu/h9.73 kW at 17°F, and 26,400 Btu/h7.74 kW at 5°F, 55% of its 47°F rating. It delivers 45,500 Btu/h13.33 kW of cooling at 95°F. At 5°F that is 10,100 Btu/h2.96 kW short of the example heating load of 36,500 Btu/h10.70 kW; at 95°F it is 27,500 Btu/h8.06 kW above the example cooling load of 18,000 Btu/h5.28 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 4-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 1,500 sq ft where winters reach 5°F: heating runs from 36,500 Btu/h10.70 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 18,000 Btu/h5.28 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 214837769 · listed by Ruud · certified Jun 2, 2026 · 9 pairings share these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 26,4007.74 kW | −27% | 2.20 | |
| 17°Ffull speed | 33,2009.73 kW | −5% | NR | |
| 47°Fnormal speed | 48,00014.07 kW | 0% | NR | |
| 95°Fcooling, full load | 45,50013.33 kW | — | NR |
EER2 11.2 in that test. SEER2 17.0 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 3.52kW
- Electrical input in the 95°F cooling test
- 4.06kW
- Seasonal average heating COP
- 2.49
These exclude backup resistance heat.
How it compares with other 48,000 Btu heat pumps
4-ton central models
- This pairing at 5°F
- 26,400 Btu/h7.74 kWNR
- This unit at 5°F median across its pairings
- 26,400 Btu/h7.74 kW
- Median of 4-ton central models at 5°F
- 36,400 Btu/h10.67 kW
- Models in this group
- 408
This unit is above 27% of them, at number 299 of 408 by heat at 5°F. The middle half of the group runs 25,350 to 46,000 Btu/h.
Closest models by heat at 5°F
- YH648E2S11York · 27,200 Btu/h
- 4HP18V60PAC Pro, Allied + 2 more · 26,600 Btu/h
- 4SHP18LX160PAirEase and Armstrong Air · 26,600 Btu/h
- HC19B4821Coleman · 26,200 Btu/h
- YZT48B21York · 26,200 Btu/h
- HRG1860S1PCentury and Comfort-Aire · 26,000 Btu/h
Every 48,000 Btu (4-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for RD17AZ48AJ3N
111 pairings · 111 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 48,000 Btu/h14.07 kWNR | 48,000 Btu/h14.07 kW |
| Heat output at 17°F full speed | 33,200 Btu/h9.73 kWNR | 32,800–43,500 Btu/h9.61–12.75 kW |
| Heat output at 5°F full speed | 26,400 Btu/h7.74 kWNR | 25,600–40,500 Btu/h7.50–11.87 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 55%NR | |
| COP at 5°F full speed | 2.20NR | 2.00–2.30 |
| HSPF2 Region IV | 8.5NR | 8.1–8.5 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 45,500 Btu/h13.33 kWNR | 45,500 Btu/h13.33 kW |
| EER2 at 95°F | 11.2NR | 10.0–12.0 |
| SEER2 cooling season | 17.0NR | 16.0–18.0 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-410A | |
| Compressor | Variable speed | |
| Indoor unit | RCFZ4821STAAM | 16 indoor units |
| Furnace | R962V0855A21M4 | 53 furnaces |
| Cold-climate designation EPA's designation, as published | NC | On some pairings |
| ENERGY STAR Most Efficient EPA's designation, as published | No | On no pairings |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | RD17AZ48AJ3N | |
Pairings, by indoor-unit class
16 indoor units · 111 certified pairings
One row per indoor unit certified with this outdoor unit.
Furnace paired · 2 indoor units
-
TCFZ6024SEANM (the pairing on screen) brand not stated 40,500 Btu/h11.87 kWat 5°F, full speed
-
RCFZ4821STAAM (the pairing on screen) brand not stated 26,200 Btu/h7.68 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| TCFZ6024SEANM (the pairing on screen) | — | 40,50011.87 | 48,00014.07 | 45,50013.33 | 84% | 2.10 | Yes | 45 |
| RCFZ4821STAAM (the pairing on screen) | — | 26,2007.68 | 48,00014.07 | 45,50013.33 | 55% | 2.30 | Yes | 43 |
Air handler · 8 indoor units
-
RH2TZ4821STANA (the pairing on screen) brand not stated 25,600 Btu/h7.50 kWat 5°F, full speed
-
RH2TZ6021STANA (the pairing on screen) brand not stated 26,400 Btu/h7.74 kWat 5°F, full speed
-
RH2VZ4821STANA (the pairing on screen) brand not stated 25,600 Btu/h7.50 kWat 5°F, full speed
-
RH3VZ6024STACN (the pairing on screen) brand not stated 40,000 Btu/h11.72 kWat 5°F, full speed
-
SH2CZ4821STANA (the pairing on screen) brand not stated 25,600 Btu/h7.50 kWat 5°F, full speed
-
SH2CZ6021STANA (the pairing on screen) brand not stated 26,400 Btu/h7.74 kWat 5°F, full speed
-
SH2VZ4821STANA (the pairing on screen) brand not stated 25,600 Btu/h7.50 kWat 5°F, full speed
-
SH2VZ6021STANA (the pairing on screen) brand not stated 26,400 Btu/h7.74 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| RH2TZ4821STANA (the pairing on screen) | — | 25,6007.50 | 48,00014.07 | 45,50013.33 | 53% | 2.30 | Yes | 2 |
| RH2TZ6021STANA (the pairing on screen) | — | 26,4007.74 | 48,00014.07 | 45,50013.33 | 55% | 2.30 | Yes | 2 |
| RH2VZ4821STANA (the pairing on screen) | — | 25,6007.50 | 48,00014.07 | 45,50013.33 | 53% | 2.30 | Yes | 2 |
| RH3VZ6024STACN (the pairing on screen) | — | 40,00011.72 | 48,00014.07 | 45,50013.33 | 83% | 2.10 | Yes | 2 |
| SH2CZ4821STANA (the pairing on screen) | — | 25,6007.50 | 48,00014.07 | 45,50013.33 | 53% | 2.30 | Yes | 2 |
| SH2CZ6021STANA (the pairing on screen) | — | 26,4007.74 | 48,00014.07 | 45,50013.33 | 55% | 2.30 | Yes | 2 |
| SH2VZ4821STANA (the pairing on screen) | — | 25,6007.50 | 48,00014.07 | 45,50013.33 | 53% | 2.30 | Yes | 2 |
| SH2VZ6021STANA (the pairing on screen) | — | 26,4007.74 | 48,00014.07 | 45,50013.33 | 55% | 2.30 | Yes | 2 |
Sold as, and units with identical certified values
Brands listing this model number
Other brands that list these model numbers
- Are Friedrich and Rheem heat pumps the same?43 shared model numbers
- Are Friedrich and Ruud heat pumps the same?43 shared model numbers
- Are Friedrich and Russell heat pumps the same?25 shared model numbers
- Are Friedrich and Sure heat pumps the same?25 shared model numbers
- Are Rheem and Ruud heat pumps the same?85 shared model numbers
- Are Rheem and Russell heat pumps the same?25 shared model numbers
- Are Rheem and Sure heat pumps the same?25 shared model numbers
Model number as listed
- RD17AZ48AJ3N 111 pairings
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
Product history
- RD17AZ48AJ3N changed its certified heat output at 47°F on 15 pairings from 45,500 Btu/h to 48,000 Btu/h in the certified data between November 2024 and September 2026.
- RD17AZ48AJ3N changed its certified heat output at 47°F on 30 pairings from 45,500 Btu/h to 48,000 Btu/h in the certified data between September 2024 and September 2026.
- RD17AZ48AJ3N changed its certified heat output at 47°F on 100 pairings from 45,500 Btu/h to 48,000 Btu/h in the certified data between March 2025 and May 2025.
- RD17AZ48AJ3N was in the certified data by September 2024.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Jun 2, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read